Woodsman Blaze Installation And Operating Instructions Manual

Summary of Blaze

  • Page 1

    1 issued: july 2009 installation and operating instructions for the following woodsman models these instructions should be read in conjunction with the flue installation instructions and drawings supplied with each hhf heatsaver flue system. Testing and certification model as/nzs 2918:2001 as/nz 291...

  • Page 2

    2 minimum safe installation clearances blaze ecr mkii manhattan & boston milford rmf rmf - rv strongman tarras & tarras-wb a 200 100 150 210 125 n/a 300 160 b 250 450 300 285 500 500 *875 550 c 300 300 300 300 300 300 515 500 d 150 150 150 150 150 150 150 150 e 100 200 140 100 180 n/a 380 300 f 371 ...

  • Page 3

    3 minimum safe installation clearances dvi-165 imf regent rmf-rv p 930 980 923 913 q¹ 380 460 333 300 r¹ 0 0 0 12 q² 352 408 309 - r² 13 25 13 - q³ 325 363 300 - r³ 25 50 >18 - q⁴ 300 300 - - r⁴ 40 88 - - s 50 50 50 - t 840 840 840 880 table 2 * if q = q¹; then r = r¹ etc..

  • Page 4

    4 installation instructions this appliance should only be installed by a trained and qualified installer. Warning: the appliance and flue system shall be installed in accordance with as/nzs 2918 and the appropriate requirements of relevant building code/codes. Warning: appliances installed in accord...

  • Page 5

    5 minimum flue height the top of the flue system should be at least 600mm above the highest point of the roof ridgeline, if the point of intersection of the flue system and the roofline is less than 3 metres from the ridgeline horizontally. If the point of intersection of the flue system and the roo...

  • Page 6

    6 operating instructions (burning wood) keep these instructions for future reference important: ensure installation instructions have been adhered to before lighting the appliance. Important: firewood should be loaded in a front to back direction when operating this appliance. Warning: any modificat...

  • Page 7

    7 set the fire using kindling wood and paper (or a solid fuel lighter), light and close the door; set the lower high - low control on high and the upper high - low control on low. Once the fire is burning brightly, decide if wood or coal is to be used. If coal is to be burned, lay the coal over the ...

  • Page 8

    8 10 year warranty 41 braddon street, po box 4043, christchurch, new zealand phone 03 366 1796, fax 03 366 1795 email: sales@hhf.Co.Nz, website: www.Harrishomefires.Co.Nz this woodsman fire is warranted for a period if 12 months to the original purchaser, from the date of purchase, against defects o...