Woodwarm Stoves Phoenix 3 Installation, Servicing & User Instructions - page 12
GB & IE
12
3. Installation instructions.
Before commencing Installation, confirm that the details on the appliance data plate correspond to the local
distribution conditions, gas type and pressure to which the appliance is to be installed.
Ensure that gas supply and supply pipe is capable of delivering the required volume and pressure of gas and is in
accordance with the rules in force.
3.1 Gas Connection
This appliance has a gas inlet connection of Ø 8mm.
3.2 Ventilation
This appliance is rated below 6.9kW, and as such needs no additional ventilation. However an adequate supply of
fresh air to maintain temperatures and a comfortable environment is recommended.
This appliance may be installed in a completely sealed or mechanically ventilated house.
3.3 Appliance Fireplace Installation
Determine the position required for the appliance.
Create a gas connection for the appliance in approximately the correct location for the gas controls.
The gas controls are connected to the Burner of the appliance.
For clearance details see section 3.3.1. below.
The clearance distance of the Flue from combustibles must not be less than 75mm. This dimension can be reduced
to 25mm as the distance from the underside and the sides of Horizontal Flue runs.
The stove must stand on a fireproof hearth, which must be of a non-combustible material with a minimum thickness
of 12mm and extend 100mm in front of the stove.
The hearth must not be capable of inadvertent covering by a rug or carpet. This may be achieved by either the
hearth being 50mm above the level of the floor, or a fender or kerb around the hearth to a height of 50mm.
3.3.1 Clearance requirements
The appliance must not be fitted against a rear wall constructed from a combustible material; a gap of 300mm
should be given around the stove before combustible materials may be used in the wall construction.
If the appliance has to be located in an opening, the minimum clearance from non-combustible materials is:
To Rear : 50mm
To Right : 50mm
To Left : 50mm
The stove must be located at least 280mm from any combustible materials.
A combustible shelf may be fitted over the appliance, if in the case of a 150mm or less deep shelf, there is at least
280mm clearance above the top of the stove. The shelf depth may increase at the same rate as the increase in
clearance; i.e. a shelf depth of 200mm would require a clearance of 330mm.