Woodwarm Stoves Phoenix 3 Installation, Servicing & User Instructions - page 23
GB & IE
23
4. Servicing
Turn the appliance OFF and isolate the gas supply. Ensure the appliance is fully cold before attempting to start
servicing the appliance. No liability can be accepted by Woodwarm for injury caused by burning or scolding by a hot
appliance.
A suggested procedure for servicing is listed below.
A. Lay out dust sheet on flooring, mask off any special fireplace materials.
B. Remove the Outer door.
C. Remove the Glass Frame Assembly.
D. Carefully remove the Ceramic components (including Embers).
E. Use a Vacuum cleaner to clean the top of the burners and grate
F. Remove Grate
G. Using a vacuum cleaner, fully clean the Burner.
H. Use the vacuum cleaner and a soft brush to clean the pilot assembly and Injectors. Never modify or bend the
Thermocouple
I. Turn on the gas supply and check for leaks, check the burners and Pilot for good condition and operation
J. Replace Grate
K. Replace the Firebed arrangements
L. Replace Window Assembly and Frame
M. Check the flue system and terminal, making sure that the terminal vent is fully clear
N. Light the appliance and test setting pressures
O. Check the safe operation of the appliance.
4.1 Cleaning the Ceramics
Remove the ceramics as detailed in A - D above.
Gently clean the ceramics in the open air, using a soft brush and a vacuum cleaner. Where necessary replace
damaged components only with genuine Woodwarm specified parts. Seal any scrap ceramics in plastic bags and
dispose at proper refuse sites. When using a vacuum cleaner, it is recommended that one with a HEPA filtering
system is used.
Re-fit the Firebed arrangement, re-seal the appliance and check the safe operation of the appliance.
4.2 Servicing the Burners
Remove the Ceramics as detailed in A - D above.
The pilot is now clearly visible, the pilot, including the Thermocouple, can be replaced/serviced by removing fully
the pilot assembly from its mounting. This is done by removing the two screws on the surface of the pilot. The
fittings on the under-side of the pilot can be un-done using a 10mm spanner where appropriate.
To access the Main Burner Injectors, the Burner base units must be removed. This is done by removing the four
bolts holding the burner in. With these bolts removed, the Burner base can be passed up through the Firebox, and
the Injectors can be easily accessed.
When replacing any parts use only original Woodwarm specified parts.