Worcester waaiu5 Operation Manual

Manual is about: green source air / air heat pump

Summary of waaiu5

  • Page 1

    Split type green source air / air heat pump operation manual * plasmacluster is a trademark of sharp corporation. Must be installed by a qualified refrigerant engineer indoor unit outdoor unit waaiu5 waaou5 part no.7 716 192 597 part no.7 716 192 598.

  • Page 2

    A. Information on disposal for users (private households) 1. In the european union attention: if you want to dispose of this equipment, please do not use the ordinary dust bin! Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper...

  • Page 3

    1 contents • important safety instructions ........... 1 • part names .................................................... 2 • using the remote control .................... 4 • setting air purifying filter .................. 5 • tips on saving energy .............................. 5 • auxiliary mode...

  • Page 4

    2 part names indoor unit 1 inlet (air) 2 open panel 3 air filter 4 air purifying filter 5 aux button 6 receiver window 7 power supply cord 8 vertical adjustment louvre 9 horizontal adjustment louvre 0 outlet (air) q remote control w plasmacluster lamp (blue) e operation lamp (green ) r timer lamp (o...

  • Page 5

    3 remote control 1 transmitter 2 display (liquid crystal display) 3 plasmacluster button 4 display button 5 on/off button 6 thermostat button 7 full power button 8 progressive airflow button 9 mode button 0 timer on button (for setting the timer) q timer off button (for setting the timer) w one-hour...

  • Page 6

    4 set current clock time there are two clock modes: 12-hour mode and 24-hour mode. Example: 5 o’clock in the afternoon clock display 12-hour mode pm 5:00 24-hour mode 17:00 1 to set to the 12-hour mode, press the clock button once in the fi rst step. To set to the 24-hour mode, press the clock butto...

  • Page 7

    5 the air purifying filters are packed as accessory of this unit. During operation of the air conditioner, the filters remove dust and tobacco smoke from the air and discharges clean air. 1 take out the air fi lters. 1 open the open panel. 2 push the air filters up slightly to unlock them. 3 pull th...

  • Page 8

    6 basic operation tips about auto mode (example: 1°c higher) c (example: 2°c lower) c 2 5 3 1 4 1 press the mode button to select the operation mode. Auto heat cool dry 2 press the on/off button to start operation. • the green operation lamp ( ) on the unit will light. 3 press the thermostat button ...

  • Page 9

    7 vertical air flow direction 1 press the swing button( ) on the re- mote control once. • the vertical adjustment louvre will swing con- tinuously. 2 press the swing button( ) again when the vertical adjustment louvre is at the desired position. • the louvre will stop moving within the range shown i...

  • Page 10

    8 press the progressive airflow button during cooling or dry operation when you do not want to feel cold air. Vertical adjustment louvre is set obliquely upward to deliver cool air to the ceiling. Press the button during heating operation. Vertical adjustment louvre is set downward to deliver the wa...

  • Page 11

    9 plasmacluster operation plasmacluster ions released into the room will reduce some airborne mold. 1 during operation, press the plasmacluster button. • the remote control will display “ ”. • the blue plasmacluster lamp on the unit will light up. To cancel press the plasmacluster button again. • th...

  • Page 12

    10 one-hour off timer when the one-hour off timer is set, the unit will automatically turn off after one hour. 1 press the one-hour off timer button. • the remote control displays “ ”. • the orange timer lamp ( ) on the unit will light up. • the unit will stop operating after one hour. To cancel pre...

  • Page 13

    11 timer on 1 press the timer on ( ) button. 2 the timer on indicator will blink; press the time advance or reverse button to set the desired time. (the time can be set in 10-minute increments.) 3 point the remote control at the receiver window on the unit and press the timer set (set/c) button. • t...

  • Page 14

    12 indoor temp. Outdoor temp. Cooling upper limit 32˚c 43˚c lower limit 21˚c –10˚c heating upper limit 27˚c 24˚c lower limit – –20˚c • the built-in protective device may prevent the unit from operating when used out of this range. • condensation may form on the air outlet if the unit operates contin...

  • Page 15

    13 maintenance after air conditioner season 1 operate the unit in the self clean operation to allow the mechanism to thoroughly dry. 2 stop the operation and unplug the unit. Turn off the circuit breaker, if you have one exclusively for the air conditioner. 3 clean the fi lters, then reinstall them....

  • Page 16

    14 the following conditions do not denote equip- ment malfunctions unit does not operate the unit will not operate if it is turned on immediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the internal mechanisms. Wait 3 minutes before...

  • Page 18

    Tinsea567jbrz 08g- th 1 operation manual greensource air to air 2008/07 en 8-716-1 15-359 worcester, bosch group is a brand name of bosch thermotechnology ltd. Cotswold way, warndon, worcester, wr4 9sw tel 01905 754624 fax: 01905 754619 worcester, bosch group is a brand name of bosch thermotechnolog...