X-10 Pro 2000 Installer's Manual - Troubleshooting
PRO2000_DR/AB-6/98
Tampa, FL33618
Technical Support: 800 832 4003
™
®
25
Troubleshooting
If you hear a repetitive trouble alarm
when you try to arm the system, and it
does not arm.
Check the zone indicators. If a door or
window is open, its zone indicator is on. If
there is a problem with a Sensor or
Motion Detector, its zone indicator
flashes slowly. Either:
• Press DISARM. Check each Door/
Window Sensor is working properly
and that no doors or windows are
open. Then arm the system.
Or:
• While the trouble alarm is sounding,
press BYPASS to override the problem
zone (its zone indicator then flashes
rapidly). Then arm the system again.
If the alarm trips when you enter the
house before you have time to disarm it.
Arm the system in the delay mode.
To do this: Set the MIN/MAX switch on
the entrance Door/Window Sensor to
MAX and the Remote Control to MAX (on
the Hand held Security Remote) and
then press ARM.
• Be sure you set House and Unit
Codes on the module(s) to the same
letter and number as downloaded to
the Console Security Light (default is
A-13).
• Be sure the light you are trying to
control has its on/off switch in the on
position.
• Be sure its bulb is good.
• Plug the module into another outlet
near the Console.
• Check that the battery indicator on the
Remote Control comes on when you
press a button. Replace battery and
re-install remote if necessary.
• Make sure Panel Power Supply is
plugged in, not running on battery.
Lights will not turn on or off from the
LIGHT ON or LIGHT OFF buttons on the
Remote Control.