X-TREME XM-3150 Operation And Maintenance Instructions - Diagnostics Indicators
14
Diagnostics Indicators
If your scooter fails to operate, please check the diagnostic indicators on the display
panel.
Symptom: Light 1 flashes
Diagnostics: This only applies to lithium powered scooters. The flashing light
indicates low voltage.
Solution: Please reduce the speed to obtain extra running miles and recharge the
scooter immediately.
Symptom: Light 2 on
Diagnostics: Faulty brake switch, kickstand down or missing, or motor overheating
can cause light 2 to illuminate.
Solutiom: Please take the following steps:
Step 1. Apply the brake lever and release it . The scooter will go back to
normal if light 2 goes off. If light 2 remains on, please do step 2.
Step 2. Kick up the side stand. The scooter will go back to normal if light 2
goes off. If light 2 remains on, please do step 3.
Step 3. Wait a few minutes until the motor cools off. The scooter will go back
to normal if light 2 goes off.
Symptom: Light 3 on
Diagnostics: Controller overheat protection
Solution:. Wait a moment untill this light goes off automatically and the scooter will
go back to normal.