SPLCD WIRING OVER CAT5:
CAT5 Wire can be used up to approximately 200ft. when wired appropriately (maximum distance may differ
depending upon wiring locations and other outside elements). Follow the appropriate wiring scheme as outlined
below:
1. Twist all four white-stripe wires together on both ends and connect to the GND terminal on both the
SPLCDCB100 and the SPLCD Controller.
2. Twist two solid colored wires together on both ends and connect to the 16VDC terminal on both the
SPLCDCB100 and the SPLCD Controller.
3. Twist the last two solid colored wires together on both ends and connect to terminal labeled IR IN on the
SPLCDCB100 and to the terminal labeled IR BUS on the SPLCD Controller.
Note: If using the STAUTS line, use one of the solid wires in step 3 for STATUS and the other for IR. This will limit
the overall distance to under 200ft.
CAUTION: When using CAT5 always measure the voltage at the rear of the SPLCD across the 16VDC and
GND terminals and confirm the voltage is between 13VDC and 16VDC.
IR RECEIVER WIRING:
1. For IR Receivers with Xantech’s Quick-Connect Stereo Mini Plug, simply plug directly into the 3.5mm IR Receiver
Jack on the SPLCDCB100 connecting block.
2. For all other wiring configurations, connect the 12VDC, GND, STATUS (optional), and IR Output wires to the
appropriate of the SPLCDCB100 Connecting Block.
3. For more than one IR Receiver, connect in parallel directly on the 4-screw WECO terminal or use a CB-18 parallel
connecting block to neatly combine up to 4-IR Receivers.
283M
Blink-IR
Mouse Emitter
283M
Emitter
283M
Emitter
DVD
Satellite Receiver
AV Receiver
SPLCD-CB
Amplified Connecting Block
EMITTERS
16 VDC
IR
RCVR
SPLCD-CB
AMPLIFIED
CONNECTING BLOCK
®
+12 VDC OUT
GND
STATUS
IR IN
GND
+12V
490-00
Series
Micro Link
IR Receivers
3-Wire
Cable
IR
OUT
GND
+12V
Red
Stripe
3-Wire
Cable
IR
OUT
GND
+12V
480-85
CFL/LCD Friendly
Dinky LinkIR
Receiver
Red
(or white)
Stripe
REMOTE ROOM 1
780-80
CFL-Friendly
J-Box IR Receiver
780-90
Plasma-Friendly
J-Box IR Receiver
REMOTE ROOM 2
REMOTE ROOM 3
REMOTE ROOM 4
GND
IR
OUT
+12V
IR OUT
GND
STATUS
+12V
780-80
IR RECEIVER
®
780-90
IR RECEIVER
®
IR
OUT
IR OUT
GND
STATUS
+12V
HIGH
IR
OUT
SPLCD
ONL
Y
+16 VDC
GND
STATUS
IR IN
Hand Held
Remote
291-90
Hidden Link
Plasma-Friendly
IR Receiver
IR
TB
SPLCDPS1
16VDC Power Supply
(To Un-Switched AC Outlet)
SPLCD57G
IR BUS
IR IN
ZONE
CONTROLLER
EXPANSION
SERIAL
GND
IR OUT
+16V IN ONL
Y
GND
ST
AT
US
IR BUS
+12V OUT
GND
GND
IR IN
+12V IN TO EXPANSION
IR RECEIVER ENABLE
TERMINATION
SMARTPAD LCD 5.7
GRAPHIC TOUCHPANEL
IR RECIEVER
CAUTION:
SPLCD ONLY!
DO NOT CONNECT
12V DEVICE
Fig. 2 – Advanced Connection: Connecting SmartPad LCD™ and Multiple IR Receivers
© 2004 Xantech Corporation