  • Page 1

    Owner’s guide xpower inverter 175 plus 400 plus 700 plus t 1-800-670-0707 (toll free) t 604-422-2777 f 604-420-2145 e customerservice@xantrex.Com www.Xantrex.Com 400 plus model shown 445-0215-01-01 printed in china 445-0215-98-01 rev. 1 dec 12, 2002.

  • Page 2: Xpower Inverter 175 Plus,

    Xpower inverter 175 plus, 400 plus, 700 plus owner’s manual.

  • Page 3

    Ii about xantrex xantrex technology inc. Is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to 1 mw utility- scale systems for wind, solar, batteries, fuel cells, microturbines and backup power applications in both grid-connected and standa...

  • Page 4

    Iii disclaimer without limiting the generality of the foregoing, unless specifically agreed to by it in writing, xantrex a) makes no warranty as to the accuracy, sufficiency or suitability of any technical or other information provided in manuals or other documentation provided by it in connection w...

  • Page 5

    Iv.

  • Page 6

    V table of contents 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 about the xpower plus inverters . . . . . . . . . . . . . . . . 7 about this guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2. Important safety information . . . . . . . . . . . ....

  • Page 7

    Vi 5. Operating the xpower inverter . . . . . . . . . . . . . . . . 28 operating conditions and guidelines . . . . . . . . . . . . 28 6. Maintaining battery condition . . . . . . . . . . . . . . . . 32 7. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 common problems . ...

  • Page 8

    7 1 introduction thank you for purchasing an xpower plus inverter. The xpower 175 plus, xpower 400 plus, and xpower 700 plus are part of a family of ultra compact and highly portable power inverters from xantrex technology inc., the leader in high-frequency inverter design. About the xpower plus inv...

  • Page 9

    8 • low battery alarm • low voltage shutdown • high voltage shutdown • overload shutdown • over temperature shutdown • short circuit protection about this guide to get the best performance from your xpower inverter, xantrex recommends that you read this guide before connecting and using the inverter...

  • Page 10

    9 2 important safety information misusing or incorrectly connecting the xpower may damage the equipment or create hazardous conditions for users. Read the following safety instructions and pay special attention to all caution and warning statements in the guide. Warnings identify conditions that may...

  • Page 11

    10 warning! Heated surface the xpower housing may become uncomfortably warm, reaching 140° f (60° c) under extended high power operation. Ensure that at least 2 inches (5 cm) of air surround the inverter. During operation, keep it away from materials that may be affected by high temperatures. Warnin...

  • Page 12

    11 caution! Some chargers for small nickel-cadmium batteries can be damaged if connected to the xpower. Do not use the inverter with the following appliances: • small battery-operated appliances like rechargeable flashlights, some rechargeable shavers, and night lights that are plugged directly into...

  • Page 13

    12 additional safety guidelines • do not insert foreign objects in the xpower outlets. • never connect the inverter to power utility ac distribution wiring. • do not use the xpower in temperatures over 104° f (40° c). • do not expose the xpower to water, rain, snow, or spray. Failure to follow these...

  • Page 14

    13 3 xpower features this section describes the main features of the xpower inverters. Ac (front) panel figure 1 shows the ac panel of the xpower 175 plus inverter. Figure 1 ac panel of xpower 175 plus 1 2 3 4.

  • Page 15

    14 figure 2 shows the ac panel of the xpower 400 plus and xpower 700 plus inverters. Figure 2 ac panel of xpower 400 plus and xpower 700 plus ac outlets xpower 175 plus an ac receptacle is located on one end of the xpower 175 plus. You can plug in any 120-volt appliances with a combined total power ...

  • Page 16

    15 xpower 400 plus two ac receptacles are located on one end of the xpower 400 plus. You can plug in any 120-volt appliances with a combined total power consumption of 320 watts or less when the inverter is turned on. Xpower 700 plus two ac receptacles are located on one end of the xpower 700 plus. ...

  • Page 17

    16 ventilation openings to prevent overheating, ensure that the ventilation openings on the front and back panels are kept clear. Dc (back) panel figure 3 shows the dc panel of the xpower 175 plus inverter. Figure 3 dc panel of xpower 175 plus.

  • Page 18

    17 figure 4 shows the dc panel of the xpower 400 plus and xpower 700 plus inverters. Figure 4 dc panel of xpower 400 plus and xpower 700 plus fan and ventilation openings: the cooling fan on the xpower 400 plus and xpower 700 plus units are designed to operate only when output power is greater than ...

  • Page 19

    18 positive and negative cabling terminals: for xpower 400 plus and xpower 700 plus, you connect the ring terminals on the power cables to these terminals. To ensure correct polarity, red must be connected to red and black must be connected to black. Figure 5 lighter plug cable 2 3.

  • Page 20

    19 figure 6 cable for direct connection to 12 volt battery caution! The xpower 175 plus can not power loads over 150 watts, so it is not equipped with cabling terminals and can not be run from a 12 volt battery..

  • Page 21

    20 types of connections product lighter plug connection cable clamps/battery connection xpower 175 plus available - a cable is permanently attached to the inverter. Figure 5 . Not available xpower 400 plus available - you must connect a separate lighter plug cable (included). Figure 5 . Available - ...

  • Page 22

    21 4 connecting the xpower plus inverters choosing a location for the best performance, place the inverter on a flat surface in a location that is: caution! The xpower must only be connected to a battery that has a nominal output of 12 volts. It will not operate if connected to a 6 volt battery and ...

  • Page 23

    22 dry do not allow water or other liquids to splash on the inverter. Cool ambient temperatures should be between 32° f and 104° f (0° c and 40° c) - the cooler the better within this range. Keep the inverter away from heating vents. Well ventilated allow at least 2 inches (5 cm) of clearance all ar...

  • Page 24

    23 connecting the xpower 175 plus and xpower 400 plus for loads under 150 watts follow these steps to connect the xpower 175 plus or xpower 400 plus inverter: 1. Place the inverter on a flat surface like the floor of your vehicle. 2. Make sure the on/off switch on the front panel is off. 3. The xpow...

  • Page 25

    24 4. Place the inverter’s lighter plug in the vehicle’s cigarette lighter socket or a 12 volt outlet. 5. Turn on the front panel on/off switch. The green power light indicates that the xpower is operating normally and that ac power is available at the outlet. 6. Plug in the ac appliance you want to...

  • Page 26

    25 follow these steps to make a direct battery connection: 1. Place the inverter on a flat surface. 2. Make sure the on/off switch on the front panel is off. Warning! Batteries contain corrosive materials and present an electrical shock hazard. To prevent irritation and burns, wear protective eyewea...

  • Page 27

    26 3. Take the cables equipped with battery clips on one end ( figure 6 ) and place the ring terminals over the two cabling terminals on the back of the inverter. (the cabling terminals are shown in figure 4 .)) caution! Reverse polarity power connections of the 12 volts dc battery to the xpower mus...

  • Page 28

    27 4. Fasten the positive (red) clip to the positive battery post, and then fasten the negative (black) clip to the negative battery post. 5. Turn on the front panel on/off switch. The green power light indicates that ac power is available at the outlets and that the inverter is operating normally. ...

  • Page 29

    28 5 operating the xpower inverter this section explains how to operate the xpower 175 plus, xpower 400 plus and xpower 700 plus most efficiently. Operating conditions and guidelines this section describes normal operation as well as conditions that trigger an alarm or automatically shut down the xp...

  • Page 30

    29 overload shutdown if you connect an ac load that is rated too high (see table 1 on page 30) or a load that draws excessive surge power, the xpower shuts down. The red fault light comes on. Over temperature shutdown the xpower shuts down automatically if it exceeds its safe operating temperature. ...

  • Page 31

    30 table 1 power and surge ratings the inverter’s ac (“modified-sine wave”) output waveform, is designed to function similarly to the sine wave shape of utility power. Most ac products correctly rated for the power rating maximums listed above or less will operate normally with the xpower inverter. ...

  • Page 32

    31 operating loads with high surge requirements the power, or wattage, rating of ac loads is the average amount of power they use. Some appliances consume more power than their power rating when they are first turned on. Tvs, monitors, and electric motors are some products that have high surge requi...

  • Page 33

    32 6 maintaining battery condition the battery operating time of the xpower depends on the charge level of the battery, battery capacity, and the amount of power drawn by the ac loads you are operating. With a typical vehicle battery, you can expect the following: table 1 battery operating times her...

  • Page 34

    33 battery will shorten its life. Therefore, when you are using a vehicle battery as a power source, start the vehicle every hour or two to recharge the battery. • the xpower will operate while the engine is running, but the voltage drop that occurs when the engine starts may trigger a low voltage s...

  • Page 35

    34 7 troubleshooting this section will help you identify the source of most problems that can occur with the xpower inverter. If you have a problem with the inverter, please review this section before contacting xantrex customer service. If you are unable to solve a problem and need to contact xantr...

  • Page 36

    35 common problems buzz in audio systems some inexpensive stereo systems have inadequate internal power supply filtering and buzz slightly when powered by the xpower. The best solution is to use an audio system with a good quality filter. Warning! Electrical shock and burn hazard do not dismantle th...

  • Page 37

    36 television interference the xpower is shielded to minimize interference with tv signals. If tv signals are weak, you may see interference in the form of lines scrolling across the screen. Try one of these suggestions to minimize or eliminate the problem: • use an extension cord to increase the di...

  • Page 38

    37 the ac load will not operate. No inverter lights are on. Inverter will run some small loads, but not larger ones. Possible cause suggested remedy battery is defective. Check battery and replace if required. The inverter has been connected with reverse dc input polarity. Check connection to batter...

  • Page 39

    38 measured inverter output is too low. Alarm is sounding. Possible cause suggested remedy a standard “average-reading” ac voltmeter has been used to measure output voltage, resulting in an apparent reading 5-15 volts too low. For accurate measurement, the xpower modified sine wave output requires a...

  • Page 40

    39 battery run time is less than expected. The ac load will not operate. The fault light is on. Possible cause suggested remedy the ac product power consumption is higher than rated. Use a larger battery to make up for the increased power requirement. The battery is old or defective. Replace the bat...

  • Page 41

    40 the ac product(s) connected are rated at less than the inverter’s continuous power rating; high starting surge has caused overload shutdown. The product exceeds the inverter’s surge capability. Use a product with a starting surge power within the xpower’s capability. Battery is discharged (alarm ...

  • Page 42

    41 8 specifications specifications are subject to change without notice. Table 1 xpower plus specifications xpower 175 plus xpower 400 plus xpower 700 plus ac output voltage (nominal) 120 volts ac 120 volts ac 120 volts ac dc input voltage range 10–15 volts dc 10–15 volts dc 10–15 volts dc continuou...

  • Page 43

    42 xpower 175 plus xpower 400 plus xpower 700 plus efficiency (maximum) 90% 90% 90% ambient operating temperature range 32° f – 104° f 0° c – 40° c 32° f – 104° f 0° c – 40° c 32° f – 104° f 0° c – 40° c low battery alarm (nominal) 10.7 volts 10.7 volts 10.7 volts low battery shutdown (nominal) 10.0...

  • Page 44

    43 9 limited warranty what does this warranty cover and how long does it last? This limited warranty is provided by xantrex technology, inc. (“xantrex”) and covers defects in workmanship and materials in your xpower plus inverter. This warranty lasts for a warranty period of 1 (one) year from the da...

  • Page 45

    44 period or 90 days from the date of the return shipment to the customer, whichever is greater. All replaced products and all parts removed from repaired products become the property of xantrex. Xantrex covers both parts and labor necessary to repair the product, and return shipment to the customer...

  • Page 46

    45 direct returns may be performed according to the xantrex return material authorization policy described in your product manual. For some products, xantrex maintains a network of regional authorized service centers. Call xantrex or check our website to see if your product can be repaired at one of...

  • Page 47

    46 1. The product if it has been misused, neglected, improperly installed, physically damaged or altered, either internally or externally, or damaged from improper use or use in an unsuitable environment; 2. The product if it has been subjected to fire, water, generalized corrosion, biological infes...

  • Page 48

    47 otherwise in connection with the product, however arising (whether by contract, tort, negligence, principles of manufacturer’s liability, operation of law, conduct, statement or otherwise), including without restriction any implied warranty or condition of quality, merchantability or fitness for ...

  • Page 49

    48 exclusions if this product is a consumer product, federal law does not allow an exclusion of implied warranties. To the extent you are entitled to implied warranties under federal law, to the extent permitted by applicable law they are limited to the duration of this limited warranty. Some states...

  • Page 50

    49 return material authorization policy before returning a product directly to xantrex you must obtain a return material authorization (rma) number and the correct factory “ship to” address. Products must also be shipped prepaid. Product shipments will be refused and returned at your expense if they...

  • Page 51

    50 2. Include the following: • the rma number supplied by xantrex technology inc. Clearly marked on the outside of the box. • a return address where the unit can be shipped. Post office boxes are not acceptable. • a contact telephone number where you can be reached during work hours • a brief descri...

  • Page 52

    51 out of warranty service if the warranty period for your xpower plus inverter has expired, if the inverter was damaged by misuse or incorrect installation, if other conditions of the warranty have not been met, or if no dated proof of purchase is available, your inverter may be serviced or replace...