    N xerox freeflow accxes firmware 10.3.3 b 106 (for hft, pun, cng controllers) june, 2006.

  • Page 2: Table of Contents

    Table of contents 1 introduction 4 1.1 feature keys: 4 1.1.1 feature key descriptions 4 2 release deliverables 6 2.1 xerox 6030/6050 wide format solution 6 2.2 xerox 8850, 510dp print systems 6 2.3 xerox print system 721p 6 2.4 xerox 8825, 8830 print systems 6 2.5 xerox print system x2 tech 7 3 reco...

  • Page 3

    8.3.6 background suppression 21 8.3.7 scaling shaded documents 21 8.3.8 50000015 errors while copying 21 8.3.9 recalling sets 21 8.3.10 washed out documents when scanning/copying 21 8.4 accxes client tools 22 8.4.1 manual feed media source 22 8.5 web print manager tool (webpmt) 22 8.5.1 printer queu...

  • Page 4: 1 Introduction

    1 introduction the accxes controller firmware release 10.3.3 b 106 provides multinational software for the xerox 6030/6050 wide format solution, xerox wide format print systems 8825, 8830, 8850, 510dp, 721p, and for the xerox wide format scan system. The languages supported are english, deutsch, esp...

  • Page 5

    Scan to print - to scan, create a preview, and send the scanned image to the printer. Must also have scan-to-net is present. Color enablement – accxes - allows color scanning when scan to net license is present. Speed enhancement turbo ii – accxes - enables 4 ips scan speed for 36” wide. Speed enhan...

  • Page 6: 2 Release Deliverables

    2 release deliverables 2.1 xerox 6030/6050 wide format solution the following executable is provided for the xerox 6030/6050 wide format solution and supports the xerox wide format scan system. Hft controller – hft_6030_10_3_3b106.Disk.Bin (file size = 7,736,382 bytes) pun controller – pun_6030_10_3...

  • Page 7

    Hft controller – hft_8830_10_3_3b106.Disk.Bin (file size = 7,640,368 bytes) pun controller – pun_8830_10_3_3b106.Disk.Bin (file size = 7,640,368 bytes) cng controller – cng_8830_10_3_3b106.Disk.Bin (file size = 10,319,876 bytes) n5t controller – n5t_8830_10_3_3b106.Disk.Bin (file size = 10,319,876 b...

  • Page 8

    3 recommended configurations table 1: minimum (min.) and recommended (rec.) ram configurations (mb) f5y, ev4, klf, and up8 controllers are no longer supported. Cng/n5t controller hft/pun controller system min. Rec. Min. Rec. 8825, 8830, 8850 128 192 128 256 510, 6030, 6050 n/a n/a 128 256 721 n/a n/...

  • Page 9: 4 Release Installation

    4 release installation notes: feature keys from before version 9.0 b180 are no longer useable with version 10.3.3 firmware. New keys must be acquired from the xerox website to use your system. Downgrading below 9.0 b 180 will also require you to re-download your feature keys. The accxes revision mus...

  • Page 10

    5 new features of 10.3.3 b 106 version 10.3.3 build 106 is intended to be a spar release for the hft, and pun controllers. The following features were added as part of those spar fixes. 5.1 additional postscript functionality versions of freeflow accxes prior to 11.3 did not apply the accxes contras...

  • Page 11: Menu (10.3.1)

    6 new features of 10.3.2 b 201 version 10.3.2 build 201 is intended to be a spar release for the hft, and pun controllers, there are no new features beyond 10.3.1. The following is a list of new features since version 10.2 of the accxes controller. 6.1 title-block setting removed from scanner ui men...

  • Page 12: 7.2 Check Plot Checkbox

    7 10.0-10.2 feature enhancements the following features were added in releases between 10.0 and 10.2 and are listed here as a convenience for users. 7.1 turbo iii speeds supported for scan-to-net the 7.33 ips scanning mode which is enabled by turbo iii feature key is now supported for scan to net sc...

  • Page 13: 7.7 Disk Image Overwrite

    7.6 support for 30 inch roll on 6030/6050 printer support of 30 inch rolls on the 6030/6050 printer changed for version 3.2.00. Version 10.1 of accxes supports 3.2.00 version of 6030/6050 printer and later. See you local service representative for proper installation and configuration of the 3.2.00 ...

  • Page 14: 8 Release Notes

    8 release notes the following information supplements the 10.X customer user guides. 8.1 controller 8.1.1 disk image overwrite 8.1.1.1 overview the disk image overwrite feature has two operations: immediate and on demand. The immediate operation overwrites image data on the hard drive immediately af...

  • Page 15

    8.1.1.3 using on demand image overwrite (odio) the on demand image overwrite (odio) feature is designed to clean the system after it has been used by overwriting the entire hdd and is activated by pressing the “start” button on the security feature web pages shown below. After pressing the “start” b...

  • Page 16

    8.1.1.4 using immediate image overwrite (iio) the immediate image overwrite (iio) feature is designed to keep the system clean while it is being used. The status of the feature is displayed on the “security” page as shown below by the solid circle. To enable or disable the feature simply press the b...

  • Page 17

    "raster stamp rejected“. Scanned images are deleted after they are processed and are not available for recall in the event of a failure of either an iio or an odio operation, a failure page will be generated. This page has a customizable string that can be used to direct the operator to take a parti...

  • Page 18

    8.1.1.5 scan to ftp the scan-to-ftp feature is enabled by the scan-to-net feature key and is configured by the “scan destinations” web page as shown below. The “scan destinations” web page can only be modified by the system administrator, assuming that the system administrator password is set to a n...

  • Page 19

    8.1.2 firmware installation of a device failed if a firmware installation fails, repeat the installation procedure. Occasionally, other events may interrupt the firmware installation on the accxes controller. 8.1.3 blank pages after firmware installation if, after a firmware installation, the system...

  • Page 20: 8.3 Scanner

    8.2 xerox 6030/6050 wide format solution 8.2.1 long plotting long plot limits are dependent on the amount of memory in the 6030/6050. Limits are as follows: amount of memory installed long plot limit 256 mb 3,000 mm 512 mb 7,500 mm 1 gb 15,000 mm if the maximum plot length in accxes (in webpmt: prin...

  • Page 21

    8.3.3 upgrade test print after upgrading to the latest scanner firmware, check the scanner configuration section at the bottom of the configuration test print. If “none” shows for the values of type, product, firmware, and vendor, then print out another test print to view the correct values. 8.3.4 s...

  • Page 22: 8.4 Accxes Client Tools

    8.4 accxes client tools 8.4.1 manual feed media source manual feed media source will be ignored when used with the accxes client tools’ page composition feature. Go to accxes client tools > job option tab > composition tab > select overlay images > media source drop down menu. Although “manual feed”...

  • Page 23

    8.5.5 large scaling factors images set to scale beyond the largest installed roll will not scale beyond the largest width unless a specific roll is selected, a specific page size is selected, or mismatch mode is set to something other than scaling. This is a behavior that has changed from previous r...

  • Page 24

    Number of 0, then select the nesting length to be 60 cm and press “update printer”, that setting becomes the nesting length setting for active user 0. If you then enter active user setup 1 and select “update printer”, the nesting length for active user 1 was also changed to 60 cm. 8.5.10 default pos...

  • Page 25: 8.6 Netscape and Unix

    8.5.13.3 if you are using internet explorer 4.0 on a windows nt system you may encounter difficulty saving pen patterns. On the webpmt go to printer defaults > pen patterns. When you choose the “save pattern” button, internet explorer may choose to automatically open your pattern in microsoft paint ...

  • Page 26: In 10.3.3. B 106

    9 customer issues resolved 9.1 the following customer issues were resolved in 10.3.3. B 106 issue description problem resolution cgm default line width the default line width was calculated incorrectly and resulted in the first drawing element or fill to be too large proportional to the size of the ...

  • Page 27: In 10.3.1 B 220

    Software controller method. Spar#884585109 unable to shift the printed file on the media area. (use marked area not functioning properly) modified internal memory allocations to support “used marked area” on larger files. Spar# 899341349 autocad wipeout does not block out background when lightness i...

  • Page 28: In 10.2 B 141

    Issue description problem resolution cpr #2005-08-18-siem06-01 default fold settings were being reset after power cycle of the controller. Fold settings are now maintained across power cycles. Initial folder configuration issues. Intermitantly the folder was not properly recognized by the controller...

  • Page 29: In 10.1 B 118

    Issue description problem resolution printers. Image wrap on 721 printers. A large number of files with lots of invalid pjl commands were submitted causing the controller to perform a large amount of error handling which caused the wrapped images. The error handling was batched so as to minimize imp...

  • Page 30: In 10.1 B 116

    9.7 the following customer issues were resolved in 10.1 b 116 issue description problem resolution job recovery for the 721 printer fails to reprint a page at end of roll. Spars #726379092, #018026417 the system did not reliably detect and reprint short pages. A new short sheet detection algorithm w...

  • Page 31: 10 Appendix

    10 appendix 10.1 controller installation for xerox wide format solution important note: the controller will only accept the installation when there are no active jobs being processed. Note: make sure that the connection to the scanner is enabled. This is done on the webpmt, by going to printer defau...

  • Page 32

    Page 32.

  • Page 33

    Prepared by: xerox corporation 800 phillips road building 139-64a webster, new york 14580-9791 usa ©xerox inc. 2006. All rights reserved. Printed in the united states of america xerox®, xerox wide format 510dp, 721p, 6030/6050, xerox wide format 8850 digital solution, xerox wide format scan system, ...