Xerox FreeFlow Release Note - In 10.2 B 141
Issue Description
Problem
Resolution
CPR #2005-08-18-SIEM06-01
Default fold settings were
being reset after power cycle
of the controller.
Fold settings are now
maintained across power
cycles.
Initial Folder configuration
issues.
Intermitantly the folder was
not properly recognized by the
controller resulting in reprinted
pages and delays in printing.
The folder configuration
routine was enhanced to
handle additional error cases
to properly recognize the
folder.
Poor copy quality for line and
normal mode copies
Certain halftone images would
be distorted when making
normal or line mode copies.
The copy path for both line
and normal mode was
enhanced to improve image
quality for 100% copies.
9.5 The following Customer issues were resolved
in 10.2 b 141
Issue Description
Problem
Resolution
721 short sheet reprint
problem
On the 721 at an end-of-roll
condition short pages are not
always reprinted.
We have improved the short
sheet detection algorithm for
the 721 to properly reprint
short or smeared pages.
Stamps Disappear when
inserted in a set and submitted
thru DST.
SPAR#62833131
The AccXES controller only
looked for the
“HPRTLNATIVEMODE”
command at the start of a job.
This PJL command is now
handled on a file by file basis
instead of on a job basis.
Synergix scanner N5T
controller hang up randomly
with 5000011 error code.
SPAR# 573361022
Invalid data was received from
the scanner during scan-to-net
mode that caused the AccXES
controller to hang.
The AccXES controller was
modified to process the valid
data only.
File loses partial blue fine grid
lines when submitted thru
AccXES.
SPAR# 171975778
The controller was not
processing the complex fine
lines correctly.
The fine-line handling
algorithm was enhanced for
this type of document.
Reduced or enlarged files
scaled to A2 are not oriented
correctly.
SPAR# 411076598
The orientation algorithm on
for copy documents did not
handle scaled documents
correctly.
The copy mode orientation
algorithm was corrected.
New text strings displayed as
“???” in non-English
languages
New strings were left out of
the non-English language files
The new strings were replaced
by translated strings.
620mm Roll not supported for
6030 / 6050 printers
Support was added for the
620mm roll on 6030/6050
Page 28