Xexun TK-103 User Manual - page 6
FUZHOU CANWELL IMPORT & EXPORT CO., LTD.
6
Tel:0086-591-87610093, 87614264 Fax:0086-591-83640189,87279269 E-mail:qqmd@fcanwell.com
Steps: 1 Open the rear cover, and pick out the battery.
2 Push the foil along and turn it left.
5.3 Startup
z Put the SIM card and battery in place.
z Turn on the unit outdoorsby pressing the “on/off” button until the indicator is on.
z For first use, please initialize the unit and restore it to default setting.
z In 10 to 40seconds, the unit will begin to work and acquire the GSM signals as well as the GPS
signals. The indicator will keep flashing every 4 seconds when the unit has received the signals,
otherwise it will keep on.
z When this unit receives GPS signals normally, you can use it and do all the following settings.
5.4 Restart the tracker.
Send SMS "reboot123456" to the tracker. If success, it will reply "sestem will reboot…",The
tracker will be restarted.
5.5 Initialization
Send “begin123456” in SMS to the unit, it will reply “begin ok” and initialize all the settings.
(123456 is default password)
5.6 Change the password
5.6.1 Send SMS "password123456 666888"to change the password. it will reply "change password
Wire for cutting off oil of the tracker
Yellow wire connects the relay feet 86;
85
feet to 12 V DC anode, 87 feet and 30 feet in
series in the supply oil circuits.
Wire for cutting off circuit of the tracker
White wire connects relay feet 86; 85 feet
to 12 V DC anode, 87 feet and 30 feet are in
series in the supply power circuits.
Emergency triggering alarm
The blue wire connects the anode of the
alarm button, and the black wire connects the
cathode of the alarm button.
Power supply line
The red wire connects 12V“+”;Black wire
connects to12V
“-”