Xpelair DX100HPTR Installation And Maintenance Instructions Manual - page 11
DX100PR / DX100PS Only
Operate the fan by pulling and releasing the cord. Repeat to switch off.
DX100HTR / DX100HTS Only.
Automatic mode - The fan automatically adjusts to slow changes in natural humidity levels without operating the fan.
If the humidity levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will
not be triggered by humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase quicker than
5% RH in 5 minutes the fan will operate. When relative humidity drops the fan continues to operate for the adjustable
time delay.
External operation - Use the external on/off switch. When the fan is switched off, the fan continues to operate for
the adjustable time delay then goes into automatic mode.
DX100HPTR / DX100HPTS Only.
Automatic mode - The fan automatically adjusts to slow changes in natural humidity levels without operating the fan.
If the humidity levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will
not be triggered by humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase quicker than
5% RH in 5 minutes the fan will operate. When relative humidity drops the fan continues to operate for the adjustable
time delay.
External operation - Use the external on/off switch. When the fan is switched off, the fan continues to operate for
the adjustable time delay then goes into automatic mode.
Pull Cord operation – Use the integral pull cord switch. When the fan is switched off, the fan continues to operate for
the adjustable time delay then goes into automatic mode.
DX100PIRR / DX100PIRS Only.
The sensor detects movement in the room and activates the fan. When movement is sensed, the fan will run for a
pre-set over-run period and any further movement sensed will re-start the sequence. This ensures that the room is
only ventilated during and immediately after use. When the fan is first installed it will run for the time set by the over-
run timer. After this time, if no movement is sensed the fan will go into stand-by mode.
All Fans
Re-fit the front cover by hooking in the top first, and then swing the cover down to clip into place.
Cleaning (recommended once a month).
1. Before cleaning, isolate the fan completely from the mains supply.
2. Remove the front cover by depressing the latch on the underside of the cover and pulling off
the front cover from the bottom.
3. To clean the front cover, either wipe it with a damp, lint free cloth or wash it with warm soapy
water. Thoroughly dry the front cover and refit.
4. Do not immerse the fan in water or other liquids to clean any other parts of the fan.
5. Do not use strong detergents, solvents or chemical cleaners
6. Allow fan to dry thoroughly before use.
7. Apart from cleaning, no other maintenance is required.
Disposal
This product should not be disposed of with household waste.
Please recycle where facilities exist.
Check with your local authority for recycling advice.