Xpr B100PAD-M Installer Manual - page 12
Right-click on the reader and select Firmware update menu (8.18)
On the Firmware update window, click on the Browse button (8.19). The
default location of the firmware files installed with PROS CS is in the folder
"Firmware".
Select the firmware file with a "xhc" extension.
Click on the Upload button
Important: Wait for the update end message. Do not turn off the reader, the
software or any communication device in between during the entire process.
8.18
FIRMWARE UPDATE
· Right-click on the reader and select the Send
configuration menu
· See the events panel to check the configuration flow
Note: The biometric reader gets its settings
automatically. This function is used if the reader was off
line while making the changes.
SEND CONFIGURATION
Send This ID for:
Unknown Finger sends the desired Wiegand when an
unknown finger is applied.
Backlight:
Backlight of the device (ON or OFF)
Buzzer:
Buzzer of the device (ON or OFF)
Finger Acceptance Flexibility:
Accepted tolerance. The recommended value is
“Automatic Secure”.
Sensitivity:
Bio-sensor sensitivity, the recommended value is 7,
most sensitive.
ADVANCED SETTINGS
8.19