XTA GQ600 Operator's Manual - page 11
To avoid ground loops, cable shields should be connected to ground at one end only. The
normal convention is that the shield is only connected at the output XLR. Provision is also
made for separately isolating each input and output shield pin permanently within the GQ600
by breaking the appropriate pcb track, where marked with a diamond using a small drill bit or
cutter. See the following diagram for details.
W= Output channel A, X= Input channel A, Y= Input channel B, Z= Output channel B
W
X
Y
Z
Security Cover. A perspex security cover is available to enclose all front panel controls and
so avoid accidental or unauthorised adjustment. To fit this cover proceed as follows:-
1.
Fit four M4 x 17mm pillars into the four front panel bushes located in between the six
panel mounting screws.
2.
Position security cover over pillars and fasten with screws and washers provided.
Warranty
This product is warranted against defects in components and workmanship only, for a period
of one year from the date of shipment to the end user. During the warranty period, XTA will,
at it's option, either repair or replace products which prove to be defective, provided that
the product is returned, shipping prepaid, to an authorised XTA service facility.
Defects caused by unauthorised modifications, misuse, negligence, act of God or
accident, or any use of this product that is not in accordance with the instructions provided
by XTA, are not covered by this warranty.
This warranty is exclusive and no other warranty is expressed or implied. XTA is not liable
for consequential damages.
GQ600 Page 9