    D ata m anagement u nit dmu-2000 o perating m anual vertex standard co., ltd. 4-8-8 nakameguro, meguro-ku, tokyo 153-8644, japan vertex standard us headquarters 10900 walker street, cypress, ca 90630, u.S.A. Yaesu europe b.V. P.O. Box 75525, 1118 zn schiphol, the netherlands yaesu uk ltd. Unit 12, s...

  • Page 2

    Installation and connection ............................................................................................................................................ 1 switches and connectors ............................................................................................................

  • Page 3

    Dmu-2000 d ata m anagement u nit page 1 dm u tr x keyboard supplied connection cable monitor ~ac in ~ac in an te nn a i nstallation and c onnection 1 . Make certain that all cables are disconnected from the transceiver. 2 . Referring to figure 1, remove the three screws from each side of the transce...

  • Page 4

    Dmu-2000 d ata m anagement u nit page 2 power switch press this switch to turn the data management unit on, after first setting the rear panel power switch to the “ i ” position. Press this switch again to turn the data management unit off. If the rear panel’s power switch is set to the “ o ” positi...

  • Page 5

    Dmu-2000 d ata m anagement u nit page 3 audio in jack this jack is audio signal input for the audio scope display of the dmu-2000 . You can observe the audio wave of a signal provided by equipment connected to this jack. Usb jack this jack supports the usb 1.1 protocol, for connec- tion of a usb key...

  • Page 6

    Dmu-2000 d ata m anagement u nit page 4 p lease r ead t his f irst when turning on the transceiver for the first time, please set the local time as soon as possible. If this is not done, the various functions of the world clock and great circle map will not function correctly. Note : if you wish to ...

  • Page 7

    Dmu-2000 d ata m anagement u nit page 5 4. C hanging the l ocation ( 1 ) using the world map choose (highlight) the “ zone ” using the [ f1 ( )] ~ [ f4 ( )] keys, then press the [ f7 ( select )] key. The name of the country associated with the high- lighted time zone may now be selected using the [ ...

  • Page 8

    Dmu-2000 d ata m anagement u nit page 6 p lease r ead t his f irst 6. C orrecting the d ate use the [ f1 ( )] and [ f2 ( )] keys to highlight “ data ,” then press the the [ f7 ( select )] key. Use the [ f3 ( )] and [ f4 ( )] keys to navigate to each column of the date, then use the [ f1 ( )] and [ f...

  • Page 9

    Dmu-2000 d ata m anagement u nit page 7 n ote.

  • Page 10

    Dmu-2000 d ata m anagement u nit page 8 b efore u sing an e xternal m onitor a bout dmu-2000 d ata m anagement u nit o peration a number of informative and useful displays will appear on the after-market monitor which is connected to the display terminal on the dmu-2000 rear panel. These include the...

  • Page 11

    Dmu-2000 d ata m anagement u nit page 9 b efore u sing an e xternal m onitor a bout dmu-2000 d ata m anagement u nit o peration “ m emory c hannel l ist ” screen “ w orld c lock ” screen “ r otator c ontrol ” screen “ a udio s cope / o scillo s cope ” screen “ s pectrum s cope ” screen “ swr m onito...

  • Page 12

    Dmu-2000 d ata m anagement u nit page 10 b efore u sing an e xternal m onitor a bout m enu m ode o peration the menu mode’s various selections and parameters can be displayed on the external monitor. For details on menu operation, please see the discussion below. E ntering the m enu m ode 1 . If you...

  • Page 13

    Dmu-2000 d ata m anagement u nit page 11 b efore u sing an e xternal m onitor there are 147 items in the menu mode, and they are grouped; the group name is displayed at the left top of the list screen. It will be convenient for you if you initially select the group, by rotating the main tuning knob,...

  • Page 14

    Dmu-2000 d ata m anagement u nit page 12 b efore u sing an e xternal m onitor main ( vfo-a ) & sub ( vfo-b ) fields these areas of the display contain information about the status of the main (vfo-a) and sub (vfo-b) vfos. Mode fields these fields indicate the operating mode in use on the above vfos....

  • Page 15

    Dmu-2000 d ata m anagement u nit page 13 b efore u sing an e xternal m onitor timer field when the on timer has been engaged, “ timer ” will appear here; when the alarm has been engaged, “ alarm ” will appear in this field. Local time-1 field the current time at your location (local time-1) is displ...

  • Page 16

    Dmu-2000 d ata m anagement u nit page 14 a bout the w orld c lock h ow to u se the w orld c lock the world clock displays the time in various countries, and the day/night areas are also indicated on the map, in- cluding the grey line near the terminator. The differ- ence between the daylight areas i...

  • Page 17

    Dmu-2000 d ata m anagement u nit page 15 h ow to u se the w orld c lock set ( local-time1 ) s etup please see the “please read this first” information (page 4). Format ( time format ) s etup this procedure lets you choose between 12-hour and 24-hour time display format. 1. While the world map is dis...

  • Page 18

    Dmu-2000 d ata m anagement u nit page 16 h ow to u se the w orld c lock city s election it is possible to select any city name which is displayed on the world clock screen. Advice : the order of the display of the cities can be changed later; for now, please just select one of the supplied city name...

  • Page 19

    Dmu-2000 d ata m anagement u nit page 17 h ow to u se the w orld c lock m iscellaneous w orld c lock s etup o ptions it is possible to change the order of selection of the city times, as well as the display color, etc. 1. On the world map screen, press the [ f4 ( list )] key to select the “city name...

  • Page 20

    Dmu-2000 d ata m anagement u nit page 18 h ow to u se the w orld c lock off t imer and a larm s etup it is easy to set the off timer and alarm times. As to the off timer, countdown intervals of 120/90/60/30/15 minutes, and off, can be selected. For the alarm setting, it is possible to choose either ...

  • Page 21

    Dmu-2000 d ata m anagement u nit page 19 n ote.

  • Page 22

    Dmu-2000 d ata m anagement u nit page 20 a bout the s pectrum s cope s pectrum s cope this page displays the spectrum scope which is conve- nient for monitoring band activity. The entire screen will become the spectrum display, and you can see both strong and weak signals clearly and eas- ily on the...

  • Page 23

    Dmu-2000 d ata m anagement u nit page 21 s pectrum s cope [ f3 ( att )] key (attenuator) by pressing this key, the display attenuation can be switched as shown below. The noise level on the band will vary according to conditions, your antenna, the time of day, etc.; please select the appropriate val...

  • Page 24: Pectrum

    Dmu-2000 d ata m anagement u nit page 22 s pectrum s cope u sing the ctr ( c enter ) d isplay m ode it is possible to see both strong and weak signals clearly and easily on the main (vfo-a) band. Also, the lbws (limited band width sweep) mode lets you perform a high-speed, high-resolution sweep of a...

  • Page 25

    Dmu-2000 d ata m anagement u nit page 23 s pectrum s cope miscellaneous functions s earching for s trong s ignals u sing the p eak s earch f eature 1. Press the [ f1 ( func )] key to show the screen for setup of the marker. 2. Press the [ f4 ( p.Srch )] key to move the marker to the highest peak sig...

  • Page 26: Pectrum

    Dmu-2000 d ata m anagement u nit page 24 u sing the lbws ( l imited b and w idth s weep ) f unction lbws (limited band width sweep) is a function that sweeps a limited segment of the spectrum scope span without changing the span (bandwidth). As the sweep segment becomes narrower, the speed becomes f...

  • Page 27: Pectrum

    Dmu-2000 d ata m anagement u nit page 25 s pectrum s cope u sing the fix ( f ixed ) m ode this feature is convenient when you want to monitor an entire amateur band. The starting point, located at the left edge of the screen, can be set via the menu. Even if the screen span (bandwidth) is changed, t...

  • Page 28

    Dmu-2000 d ata m anagement u nit page 26 a bout the a udio s cope and o scilloscope a udio s cope and o scilloscope [ f2 ( mode )] key the scan mode for the left-side audio scope can be changed. By pressing this key, the mode changes: normal wf-1 wf-2 normal ...... “ wf-1 ” and “ wf-2 ” are “waterfa...

  • Page 29

    Dmu-2000 d ata m anagement u nit page 27 a udio s cope and o scilloscope u sing the a udio s cope the audio scope is particularly useful when making adjustments to the transmitter, especially when setting up the speech processor as well as the parametric microphone equalizer. On receive, you can obs...

  • Page 30

    Dmu-2000 d ata m anagement u nit page 28 u sing the o scilloscope both tx and rx waveforms can be observed, allowing optimal adjustments of setup options or filter settings, on voice, cw, and digital modes. 1. Press the [ f6 ( level )] key to set the level as appro- priate for the signal strength be...

  • Page 31

    Dmu-2000 d ata m anagement u nit page 29 n ote a udio s cope and o scilloscope.

  • Page 32

    Dmu-2000 d ata m anagement u nit page 30 a bout the l og b ook l og b ook f unction [ f1 ( func )] key you may use the “check” function to check the log to see if a qso has been made previously with the logged station, and you may also create a summary of qsos by band and mode by pressing this key. ...

  • Page 33

    Dmu-2000 d ata m anagement u nit page 31 l og b ook f unction l og b ook e xample enter key [ f1 ( func )] [ f4 ( edit )] [ f7 ( save/load )] [ f4 ( check )] [ f5 ( summary )] [ f6 ( config )] enter key [ f6 ( setting )].

  • Page 34

    Dmu-2000 d ata m anagement u nit page 32 config s etting up to five users may be registered into the logbook. For use in a contest or otherwise, the settings for each operator may be stored for later recall when that operator signs on. The operator’s identification may be entered into the name colum...

  • Page 35

    Dmu-2000 d ata m anagement u nit page 33 l og b ook f unction config s etting config setting m ode s etup logging type ( setup of log preferences ) contest : this is a concise log format, with callsign, rst, rem (remarks) only being entered by the op- erator; the date, time, band, and mode will auto...

  • Page 36

    Dmu-2000 d ata m anagement u nit page 34 l og b ook f unction l og b ook d ata i nput log data may be entered by the user. Depending on the user setup (config) for “logging type,” there are two logging modes: in the “contest” mode, the operator just enters the callsign, signal report, and the rem (“...

  • Page 37

    Dmu-2000 d ata m anagement u nit page 35 quick point : in the step 2 above, before doing a check for a duplicate qso, a copy is made of the qso record, and you may then do editing of that record. Use the [ f1 ( )], [ f2 ( )], [ f3 ( )], and [ f4 ( )] keys to select an item from among “ call ,” “ rst...

  • Page 38

    Dmu-2000 d ata m anagement u nit page 36 l og b ook f unction l oading l og d ata ( load ) you may load log data from a cf card into your dmu-2000 (for example, an archive copy, or a log from a different dmu-2000 or ft dx 9000 series trasnceiver). Before starting, be sure the cf card containing the ...

  • Page 39

    Dmu-2000 d ata m anagement u nit page 37 s ummary c heck you may do a band-by band, mode-by mode, or “all log” summary of your log data. M ode - based s ummary c heck 1. Referring to figure on page 29, press the [ f5 ( summary )] key to bring up the “ summary mode ” page, and you may then press the ...

  • Page 40

    Dmu-2000 d ata m anagement u nit page 38 a bout the t emperature /swr i ndication t emperature / swr i ndication [ f2 ( marker )] key this key turns the marker on the swr characteristic graph on and off. The marker lets you identify quickly the frequency on which a particular swr reading is being ob...

  • Page 41

    Dmu-2000 d ata m anagement u nit page 39 g raphic m eter d isplays t emperature / swr i ndication vdd the drain voltage of the final fets is measured and displayed here. In the ft-2000 (100 w version), the measurement range is 0 ~ 18 v, and the proper voltage is around 13.8 v. On tx, if around 13.8 ...

  • Page 42

    Dmu-2000 d ata m anagement u nit page 40 t emperature / swr i ndication s wept swr d isplay it is possible to show the swr characteristics and antenna performance on a graph by measuring the swr at various points across an amateur band. In order to measure the swr of the antenna system cor- rectly, ...

  • Page 43

    Dmu-2000 d ata m anagement u nit page 41 t emperature / swr i ndication u sing the m arker on the swr g raph it is possible to read the measured swr value by placing the marker onto the desired frequency (measurement test point) of the swr graph. 1. Press the [ f2 ( marker )] key to turn the marker ...

  • Page 44

    Dmu-2000 d ata m anagement u nit page 42 a bout the g reat c ircle m ap / r otator c ontrol function s creen g reat c ircle m ap / r otator c ontrol function [ f1 ( zone )] key this key moves you to a screen used for input of the location of the other station. When the country name and the city name...

  • Page 45

    Dmu-2000 d ata m anagement u nit page 43 g reat c ircle m ap / r otator c ontrol function [ f4 ( mode )] key by pressing this key, the rotation control mode can be selected. With every momentary press, the mode changes as shown below. The mode is indicated in the middle of the display. Manual preset...

  • Page 46

    Dmu-2000 d ata m anagement u nit page 44 manual m ode it is possible to operate/control the rotator manually. If the other station’s location has been entered, the location of the other station and yours will be connected with a line on the great circle map, and you can rotate the antenna manually t...

  • Page 47

    Dmu-2000 d ata m anagement u nit page 45 g reat c ircle m ap / r otator c ontrol function preset m ode the preset mode lets you set the desired direction of the rotator in advance, so you can automatically rotate your yaesu rotator to the designated direction. Use of a yaesu rotator ( g-800dxa , g-1...

  • Page 48

    Dmu-2000 d ata m anagement u nit page 46 memory m ode it is possible to rotate the antenna automatically to a direction or directions which you store into memory in advance. Use of a yaesu rotator ( g-800dxa , g-1000dxa , or g-2800dxa ) requires the connection of the optional t9101556 cable to the c...

  • Page 49

    Dmu-2000 d ata m anagement u nit page 47 a bout the m emory c hannel l ist u sing the m emory c hannel l ist [ f2 ( load )] key press this key to load memory data previously saved on the cf card to the transceiver. [ f3 ( save )] key press this key to save the current memory data to the cf card. [ f...

  • Page 50

    Dmu-2000 d ata m anagement u nit page 48 e rasing a m emory c hannel /r estoring an e rased m emory c hannel you can erase data from any memory channel which is no longer needed. It also is possible to restore (immediately after deletion) erased memory channel data, in case you erase something by ac...

  • Page 51

    Dmu-2000 d ata m anagement u nit page 49 u sing the m emory c hannel l ist l oading m emory d ata loading memory data from the cf card to the memory on the ft-2000 . 1. Press the [ f2 ( load )] key to open the memory load- ing window. If there are multiple file names stored on the cf card, select th...

  • Page 52

    Dmu-2000 d ata m anagement u nit page 50 a bout the menu m ode the ft-2000 ’s menu mode includes 147 different settings, used for configuration of various transceiver features and functions that generally are set once, and then seldom changed. Press the [ menu ] button momentarily to bring up the me...

  • Page 53

    Dmu-2000 d ata m anagement u nit page 51 u sing the m enu m ode e xplanation of the f unction k eys on the m enu m ode s creen [ f2 ( load )] key press this key to download previously-used menu settings from the cf card to the transceiver. [ f3 ( save )] key press this key to save the current menu s...

  • Page 54

    Dmu-2000 d ata m anagement u nit page 52 m enu m ode c onfiguration c hanges when you want to change something in a menu mode setting, follow the procedure described below. 1. Press the [ menu ] button momentarily. The monitor will display the menu page. Included on this page will be the menu group,...

  • Page 55

    Dmu-2000 d ata m anagement u nit page 53 u sing the m enu m ode [ f3 ( save )] key [ f3 ( go )] key s aving m enu c onfiguration d ata you may save the current menu configuration data to the cf card, for archive purposes or for quick changes in extensive transceiver settings for different operating ...

  • Page 56

    Copyright 2006 vertex standard co., ltd. All rights reserved no portion of this manual may be reproduced without the permission of vertex standard co., ltd. Printed in japan 0611x-ay e a e 9 6 x 1 0 1.