YAESU HF/50 mHz Transceiver FT-450 User’s Manual
- 24 -
7.5
Adaptation to exclude bands and modes
MY BAND, MY MODE - defaults ON (all bands and modes) out of OFF or ON
To enable or disable the 10 bands shown in Table 3 (GEN stays on) or the 6 modes shown in table
2, we insert a step in standard adaptation procedure. After selecting MY BAND or MY MODE we
must pressg the “BAND▼” and “BAND▲” or “MODE▼” and “MODE▲” buttons to select the
appropriate band or mode respectively before rotating the “DSP/SEL” knob to set each band or
mode to OFF or ON.
Hint: I rarely use the 6 meter band and chose to disable it. I then found that I could not access the
33 mHz through 60 mHz portion of the spectrum without first changing the adaptation after which
I would change it back. I solved the problem by setting up one memory channel in the upper
portion of the spectrum. By selecting that channel, I can now access anywhere in that portion of the
spectrum without changing adaptation.
7.6
Adaptation for microphone
MIC EQ – default 0 out of 0 ~ 9
Set one of the DSP microphone equalizer values
MICGAIN – default NOR out of LOW, NOR, or HIGH
Set the microphone gain. Note: in LOW setting the speech processor is turned off automatically.
Otherwise it is turn on automatically.
MICSCAN – default ON out of ON or OFF
Default scanning on DWN/FST/UP microphones. May be replaced by PM_DWN, PM-UP below.
When off, the frequency will scan DWN or UP as long as the button is held down and stop when
the button is released. If this parameter is set to ON, if the DWN or UP button is held down for
more than 1 second, scanning will continue even after the button is released.
P M-DWN – default DOWN out of
Table 9, Table 10, Table 11, or Table 12
Adaptable button on some microphones. One of 53 functions shown in Table 9, Table 10, Table
11, or Table 12 can be assigned to the DWN button.
P M-FST – default N/A out of
Table 9, Table 10, Table 11, or Table 12
Adaptable button on some microphones. One of 53 functions shown in Table 9, Table 10, Table
11, or Table 12 can be assigned to the FST button.
P-M-UP – default UP out of
Table 9, Table 10, Table 11, or Table 12
Adaptable button on some microphones. One of 53 functions shown in Table 9, Table 10, Table 11,
or Table 12 can be assigned to the UP button.
7.7
Adaptation of repeater communication
RPT – default SIMPLEX out of
-SHIFT, SIMPLEX, or +SHIFT
Set repeater shift direction.
RPT SFT – defai;t 100 kHz for HF, 1 mHz for 6 meter out of 0.00 ~ 99,99 mHz
Set magnitude of the repeater shift on the 28 or 50 mHz bands.