Programming
Step 1: Pull out the Door contact battery tab.
Step 2: Login to the engineer menu on the
control panel. Select “Zone Settings” → “Zone
Config.” → “Add Zone” on the menu. Press OK
and the LCD of the Control Panel will display
“*Push button on* Device to add”.
Step 3: Press Door contact’s Learn button.
Step 4: If the Control Panel detects a signal
transmitted from the door contact, the Control
Panel will display “Detected (OK?) DC sensor”.
Press OK to confirm the learning.
Step 5: Refer to the operation manual (section
“Add Zone”) of your Control Panel to complete
the learn-in parameter setup.
Step 6: To find the best installation location for
the door contact, you will need to make a “Walk
Test”. Press the “Return” button and go back to
the root selection. Select the “Testing” Menu,
then select the “Walk Test” option.
Step 7: Hold the door contact in the desired
location and press the test/learn button. The
RSSI signal strength value will be displayed
on the control panel, varying from 0 ~ 9
(with 9 indicates the best signal strength
performance). It is suitable for installation if the
RSSI value is 5 or greater. Device is now ready
for mounting.
Mounting
Mounting Methods
There are two ways to mount the DC, by either
self-adhesive tape or screw mounting.
Choosing location:
• Installationdirection:Makesureyoumount
the ENA-DC vertically or horizontally. Other
installation directions, except vertical or
horizontal direction, will turn the tilt switch ON
and trigger the Tamper.
Correct
Incorrect
• Themagnetshouldnotbemorethan20mm
from the detector when the door is closed.
Magnet
•Alignthedoorcontacttobethesamelevel
as the magnet. See diagram. Use the supplied
magnet spacer to increase the height of the
magnet switch if necessary (only suitable for
screw mounting).
The magnet switch can be aligned to the left or
right of the Main DC unit. See rib marking on the
DC main unit for location guidance.
Self adhesive installation
Step 1: Do not use the adhesive pad method of
installation on a surface with peeling or cracked
paint, or on a rough surface. Clean the surface
with a suitable degreaser.
Step 2: Apply the adhesive pad to the back of the
Door contact and magnet.
Step 3: Please align the magnet to the rib
marking of the DC main unit. Attach both units
to desired location.
Step 4: Press and hold the Learn / Test button for
more than 8 seconds to enable tilt tamper.
Screw Mounting
The DC base cover has two knockouts, where the
plastic is thinner, for mounting purposes.
Step 1: Remove the door contact base cover.
Break through the two knockout holes for wall
mounting.
Step 2: Using the holes as a template (Door
contact base cover and magnet), drill holes on
the mounting surface.
Step 3: Insert wall plugs if necessary and fix the
base cover and magnet on the mounting surface.
Step 4: Replace the door contact front cover.
Step 5: Press and hold the Learn / Test button for