Yale Real Living Installation And Programming Instructions

Other manuals for Real Living: Installation And Programming Instructions
Manual is about: Touchscreen Deadbolt Lock

Summary of Real Living

  • Page 1

    1 p/n ayrd-210-inst-ful rev d x4 x2 x3 #8-32 x 5/16" machine screws #7 wood & #8-32 machine x 20mm combination screws m6x47mm long through bolt yale real living™ push button deadbolt installation and programming instructions.

  • Page 2: Preparing Door

    2 p/n ayrd-210-inst-ful rev d preparing door.

  • Page 3

    3 p/n ayrd-210-inst-ful rev d o x4 1 defaut 2-3/8" position 2-3/4" position installing latch & strike plate press pull optional bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism..

  • Page 4: Installing Keypad Escutcheon

    4 p/n ayrd-210-inst-ful rev d 2 installing keypad escutcheon outside of door inside of door bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism..

  • Page 5

    5 p/n ayrd-210-inst-ful rev d x2 3 installing interior mounting plate loosen screw to remove cover..

  • Page 6: Attaching The Cable Assembly

    4 attaching the cable assembly 6 p/n ayrd-210-inst-ful rev d.

  • Page 7

    7 p/n ayrd-210-inst-ful rev d x3 5 installing interior escutcheon.

  • Page 8: Testing Operation

    8 p/n ayrd-210-inst-ful rev d 3 testing operation bolt must be in retracted (unlocked) position before installing aa batteries..

  • Page 9: Testing Operation

    9 p/n ayrd-210-inst-ful rev d 2 testing operation.

  • Page 10: Installing Batteries & Cover

    10 p/n ayrd-210-inst-ful rev d 6 7 installing batteries & cover congratulations, you've installed the yale real living™ push button deadbolt! Turn sheet over for programming instructions to customize your product. Installing optional radio module tighten screw to replace cover. "welcome to yale real...

  • Page 11: Programming Instructions

    Low battery warning- flashes red lock-out mode- keypad flashes programming instructions master pin code must be created before any further programming. Max user codes = 250 with network module. Max user codes = 25 without. 11 p/n ayrd-210-inst-ful rev d.

  • Page 12: Creating Master Pin Code

    1 creating master pin code press press enter 4-8 digit master pin code. Press press 12 p/n ayrd-210-inst-ful rev d.

  • Page 13: Creating User Pin Codes

    2 creating user pin codes master pin code must be created first. *max user codes = 250 with network module. Max user codes = 25 without. Enter master pin code press enter user number (1-25) or (1-250)* enter 4-8 digit pin code press press press press press press 13 p/n ayrd-210-inst-ful rev d.

  • Page 14: Code Chart

    14 p/n ayrd-210-inst-ful rev d 3 pin code management (with network module - up to 250 users) master user ___ user ___ user ___ user ___ user ___ user ___ user ___ user ___ user ___ user ___ user ___ user ___ user ___ user ___ user ___ code chart duplicate if necessary user name user type pin code un...

  • Page 15: Factory Settings

    15 p/n ayrd-210-inst-ful rev d when lock is reset to factory defaults all user codes (including the master pin code*) are deleted and all programming features are reset to original default settings (see below). 1. Remove the battery cover and batteries. 2. Remove the interior escutcheon to access th...

  • Page 16: Definitions

    16 p/n ayrd-210-inst-ful rev d definitions all code lockout mode: this feature is enabled by the master code. When enabled, it restricts all user (except master) pin code access. When attempting to enter a code while the unit is in lockout, the keypad flashes 8 times and the lock beeps 3 times as well...

  • Page 17: Using Master Pin Code*

    17 p/n ayrd-210-inst-ful rev d feature programming through menu mode using master pin code* m u inside indicator light advanced lock settings automatic re-lock one touch locking continue privacy button setting handing the lock enable disable enable disable enable disable enable disable performs auto...

  • Page 18: Programming Troubleshooting

    18 p/n ayrd-210-inst-ful rev d programming troubleshooting * when batteries are replaced, network locks have a real time clock that will be set through the user interface (ui); it is recommended to verify correct date and time particularly those locks operating under daylight saving time (dst). Symp...

  • Page 19: Hardware Troubleshooting

    19 p/n ayrd-210-inst-ful rev d l w t changing lock: replacing cylinder hardware troubleshooting cycle lock in both the locked and unlocked positions. If problems are found: 1-3/8"* - 2" thick doors: l = 3-1/2" (88.8mm) 2" - 2-1/4" thick doors: l = 3-3/4" (95.3mm) w = .2" (5.2mm) tailpiece t = .098" ...

  • Page 20

    20 p/n ayrd-210-inst-ful rev d yale® is a registered trademark of yale security inc., an assa abloy group company. Yale real living™ is a trademark of yale security inc., an assa abloy group company. Copyright © 2014, yale security inc., an assa abloy group company. All rights reserved. Reproduction...