Yale RH00130S Use, Care And Installation Manual

Summary of RH00130S

  • Page 1

    Use, care, and installation guide model number: serial number: dec10.0101 rh00130s rh00136s rh00230g rh00236g rh00330g rh00336g rh00336s.

  • Page 3: Able of Contents

    1 safety notice ................................................................. 2-3 list of materials ....................................................... 4 installation ducting calculation sheet ....................................... 5 mounting height & clearance ................................

  • Page 4: Important Safety Notice

    Important safety notice read and save these instructions 2 warning to reduce the risk of fire or electric shock, do not use this fan with any solid-state control device. Warning to reduce the risk of fire electric shock, or injury to persons, observe the following: a. Use this unit only in the manne...

  • Page 5: Important Safety Notice

    Important safety notice 3 warning to reduce the risk of fire, use only metal ductwork. Not for use in outdoor cooking environments. Caution )^ attics, crawl spaces or garages. Operation "j'' and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instr...

  • Page 6: List of Materials

    List of materials 4 (3) wire nuts (3) m6 x 1-1/2” (2) m6 x 1” (4) 3/16” x 1/4” (rh002 & rh003 only) (2) m3.5 x 8 (1) 5 x 12 parts not supplied - ducting, conduit and all installation tools - cable connector (if required by local codes) - duct cover extension accessory - recirculating kit accessory h...

  • Page 7: Installation –

    5 duct pieces total equivalent number length x used = 3- 1/ 4” x 10” rect., straight 1 ft. X ( ) = ft. 8” round, straight 1 ft. X ( ) = ft. 3- 1/ 4” x 10” rect. 90 0 elbow 15 ft. X ( ) = ft. 3- 1/ 4” x 10” rect. 45 0 elbow 9 ft. X ( ) = ft. 3- 1/ 4” x 10” rect. 90 0 flat elbow 24 ft. X ( ) = ft. 3- ...

  • Page 8: Installation –

    Installation – mounting height & clearance 6 ducting a minimum of 6” round duct must be used to ^ always use rigid type metal ducts only. Flexible use calculation worksheet to compute total duct _?ƒ` always, when possible, reduce the number of transitions and turns. If a long duct run is required, i...

  • Page 9: Installation –

    7 warning fire hazard never exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid metal ductwork only. /Š‹")x) some ducting options installation –...

  • Page 10: Installation –

    8 3 7/16 ” 13 /16 ” 3 15/16 ” 8 3/4 ” 29 15/16 ” or 35 7/8 ” 1 9/16 ” 6 7/8 ” 19 3/4 ” 12” 13 5/16 ” 12 5/16 ” 3 15/16 ” min. Ducted - 27 1/2 ” min. Recirc. - 32” maximum - 42 1/2 ” 41.3° front side top back installation –.

  • Page 11: Installation –

    9 installation – 16 9/16 ” 8 15/16 ” 6 7/8 ” 15 1/8 ” 19 3/4 ” 10 5/8 ” 19 11/16 ” 10 3/8 ” 30” or 35 7/16 ” min. Ducted - 22” min. Recirc. - 26” maximum - 42” front side top back 3 7/8 ” 3 15/16 ” 6” 20

  • Page 12: Installation –

    10 installation – 17 1/4 ” 8 15/16 ” 15 7/8 ” 6 7/8 ” 19 3/4 ” 10 5/8 ” 23 15/16 ” 10 3/8 ” 30” or 35 3/16 ” min. Ducted - 23” min. Recirc. - 27” maximum - 42” front side top back 2 5/16 ” 3 15/16 ” 3 15/16 ” 6”.

  • Page 13: Installation –

    11 installation – mounting the hood, rh001 1. Measure from range top to hood bottom and mark line a. _zŒ` 2. Plum and mark center line. [ (=_z \ (!‹;=_[ ƒ /_z`Œ^ fasten screws all the way. Note: wood blocking may need to be added behind the drywall if no studs are present. Wall anchors may also b...

  • Page 14: Installation –

    12 installation – mounting the hood, rh002 1. Measure from range top to hood bottom and mark line a. _zŒ` 2. Plum and mark center line. [ (=_ƒ \ (!‹;_“ ƒ /_z`Œ^ do not tighten all the way. Note: wood blocking may need to be added behind the drywall if no studs are present. Wall anchors may also b...

  • Page 15: Installation –

    13 1. Measure from range top to hood bottom and mark line a. _zŒ` 2. Plum and mark center line. [ (=_ƒ \ (!‹;_“ ƒ /_z`Œ^ do not tighten all the way. Note: wood blocking may need to be added behind the drywall if no studs are present. Wall anchors may also be used but check local codes before usin...

  • Page 16: Installation –

    14 ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust ) circulated back within the home. We recommend to always exhaust air outside o...

  • Page 17: Features & Controls -

    15 blower off lights on/off 1 3 2 blower speed selection blower off the blower will be powered off by pressing: blower speed selection select one of three speed levels by pressing: lights on/off power lights on and off by pressing: 3 features & controls - mechanical controls.

  • Page 18: Maintenance –

    16 surface maintenance: clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive st...

  • Page 19: Maintenance –

    17 replacing light bulbs caution: light bulb becomes extremely hot when turned on. Do not touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. +"—=ˆŒ„' stops and falls out. Q'^ the bulb or use a rubber/latex ...

  • Page 20: Roubleshooting

    18 t roubleshooting troubleshooting procedures issue cause what to do after installation, the unit doesn’t work. 1. The power source is not turned on. 1. Make sure the circuit breaker and the unit’s power is on. 2. The power line and the cable locking connector is not connecting properly. 2. Check t...

  • Page 21: Iring Diagrams

    19 w iring diagrams rh00130s/136s rh00230g/236g rh00330g/336g/336s 426w 326w 3.3a 3.3a.

  • Page 22: List of Parts &

    20 description part# replacement parts ;=$> ˜„= optional accessories +% ++%„„_+„„` ++%„„z_+„„z` ++%„„[_+„„[` replacement charcoal filter z0f-c002 x!"*^_z™` +*š„„_+„„` +*š„„z_+„„z›+„„[` to order parts, visit us online at www.Ventingservices.Com or call us at 1.888.750.1698 list of parts & access...

  • Page 23

    21.