Yale RH00529S Use, Care And Installation Manual - Installation –
Installation –
Mounting Height & Clearance
6
DUCTING
A minimum of 8” round must be used to maintain
maximum air flow efficiency.
Always use rigid type metal ducts only. Flexible
ducts could restrict air ow by up to 50%.
Also use calculation (on page 5) to compute total
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and re hazard; while hoods
mounted too high will be hard to reach and will
lose its performance and ef ciency.
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range. Always check your
local codes for any differences.
RH00529S & RH00538S
Vertical Ducting:
8” round minimum
Horizontal Ducting:
N/A
Min 26" - Max 36"
36"
DAMAGE-SHIPMENT / INSTALLATION:
- Please fully inspect unit for damage before
installation.
- If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
- If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
- If the unit is damaged by the installer (if other
than the customer), repair or replacement must
be made by arrangement between customer
and installer.