Yamaha MDF3 Midi Data Format - page 3
3
2.5.2 START
STATUS
11111010
($FA)
The MDF3 starts recording or playback of the selected file when a start message is received while recording
or playback is paused in SEQ mode, if the “MIDI control” function is set to “on”. If the MDF3 was paused at
a location other than the start of a file, the MDF3 begins recording or playback from the paused location rather
than from the beginning of the file.
The MDF3 transmits a start message when recording or playback is started at the beginning of a file in SEQ
mode, if the “MIDI control” function is set to “on”. The MDF3 does not transmit a start message when the
“MIDI control” function is set to “off”.
2.5.3 CONTINUE
STATUS
11111011
($FB)
The MDF3 starts recording or playback of the currently selected file at the current position when a continue
message is received while recording or playback is paused in SEQ mode, if the “MIDI control” function is set
to “on”.
The MDF3 transmits a continue message when recording or playback of a file is started in SEQ mode, if the
“MIDI control” function is set to “on”.
2.5.4 STOP
STATUS
11111100
($FC)
The MDF3 stops recording or playback of a file when a stop message is received while recording or playing
back a file in SEQ mode, if the “MIDI control” function is set to “on”.
The MDF3 transmits a stop message when recording or playback is stopped in SEQ mode, if the “MIDI
control” function is set to “on”.
2.5.5 ACTIVE SENSING
STATUS
11111110
($FE)
The MDF3 outputs an active sensing signal every 200 msec while its power supply is turned on. It does not
receive active sensing signals,