  • Page 1

    Version 0.1 8 june 2011 www.2myhome.Eu quick start mygate eu technical specs normal operating voltage 15vac power supply frequency range 868.42 mhz range up to 30m line of sight basic operations - the mygate can configure, include, exclude and control any z-wave device. - the mygate can apply rules ...

  • Page 2

    Version 0.1 8 june 2011 www.2myhome.Eu functionality of the ‘learn’ button the learn button, also located at the back of the mygate serves multiple purposes: 1. Send a z-wave ‘node information frame’, which can be used to perform z-wave associations. 2. Include the mygate into another network, becom...

  • Page 3

    Version 0.1 8 june 2011 www.2myhome.Eu delete all z-wave network information and create a new network in order to remove all z-wave network information (perform a ‘controller reset’), please take the following actions. Note that this is only possible when the mygate is included in an already existin...

  • Page 4

    Version 0.1 8 june 2011 www.2myhome.Eu technical manual caution: - this device is using a radio signal that passes through walls, windows and doors. The range is strongly influenced by local conditions such as large metal objects, house wiring, concrete, furniture, refrigerators, microwaves and simi...

  • Page 5

    Version 0.1 8 june 2011 www.2myhome.Eu normal (end consumer) operation when the mygate has a correct internet connection it will connect automatically to the 2myhome server (in the netherlands). Using the 2myhome web user interface, the end consumer can upload pictures of his house, select a package...

  • Page 6

    Version 0.1 8 june 2011 www.2myhome.Eu technical details basic type: basic_type_static_controller generic type: generic_type_static_controller specific type: specific_type_not_used listening: true, z-wave lib: 4.51 controller a controller in the z-wave terminology is defined as a unit that has the a...

  • Page 7

    Version 0.1 8 june 2011 www.2myhome.Eu supporting command classes class: 0x81 command_class_clock class: 0x70 command_class_configuration class: 0x8c command_class_geographical_location class: 0x9a command_class_ip_configuration class: 0x72 command_class_manufacturer_specific class: 0x8f command_cla...

  • Page 8

    Version 0.1 8 june 2011 www.2myhome.Eu 3. External screen page description: obtain/change the current page displayed on external displays using the screen meta data command class. What is displayed on each of these pages can be configured using the 2myhome graphical web interface. Size: 1 byte writa...

  • Page 9

    Version 0.1 8 june 2011 www.2myhome.Eu controlling command classes class: 0x71 command_class_alarm class: 0x85 command_class_association class: 0x20 command_class_basic class: 0x80 command_class_battery class: 0x70 command_class_configuration class: 0x72 command_class_manufacturer_specific class: 0x...

  • Page 10

    Version 0.1 8 june 2011 www.2myhome.Eu class: 0x72 command_class_manufacturer_specific the manufacturer specific command class is used to identify the manufacturer and device type of a device. This information is used to identify and configure the device in the 2myhome graphical web-interface. Class...

  • Page 11

    Version 0.1 8 june 2011 www.2myhome.Eu class: 0x26 command_class_switch_multilevel the multilevel switch command class can used to control devices that can be set the a numerical value (most of the time a percentage). Examples are dimmers are curtain control devices. Class: 0x63 command_class_user_c...