Z-Wave SM103 Manual - page 2
2
Choosing A Mounting Location
The Door/Window Detector is suitable for mounting in dry interior locations only.
Decide which doors/windows are to be protected by Door/Window Detectors,
(usually the front and back doors as a minimum will have Door/Window Detectors
fitted). Additional detectors may also be fitted where required to other vulnerable
doors or windows, (e.g. garage, patio/conservatory doors etc).
Note
: Take care when fixing the Detector to a metal frame, or mounting within 1m of
metalwork (i.e. radiators, water pipes, etc) as this could affect the radio range of the
device. If required, it may be necessary to space the magnet and detector away
from the metal surface using a plastic or wooden spacer to achieve the necessary
radio range.
Installation
1. Undo and remove the fixing screw from the bottom edge of the Detector.
Remove the rear cover.
2. Fit 3 1.5V AAA batteries supplied to the battery compartment.
Note
: The adoption of alkaline battery is highly recommended, as it would last
for longer period.
3. By releasing the tamper switch without being pressed on the Detector, detach or
close the magnet from the Detector, the LED on the Detector will illuminate.
4. Using the rear cover as a template, mark the positions of fixing holes on the
fixed part of the frame along the opening edge opposite the hinges using
screws provided.
5. Refit the Detector to the rear cover and secure with the fixing screw supplied.
Do not over tighten the fixing screws as this may distort or damage the casing.
6. Fit the Magnet to the moving part of the door/window opposite the Detector
using the adhesive tape or 19mm fixing screws.
Ensure that the parallel gap between the Magnet and Detector is less than
10mm and that the matching line on the Magnet is pointing towards and aligned
with the line on the Detector.
7. If several windows need to be protected, adopt the wire according to the
specifications as mentioned below. This should be wired to the terminal block
provided in the battery compartment in series connection. The wired contact
should be connected using two core (24AWG) wire of maximum length 4m.
A cable entry cut-out is available and adjacent to the terminal block.
Internal connection External wired connection
Choose either the internal or external wired connection, both of which types cannot
be in existence at the same time.
Note:
After removing batteries, wait for 5 seconds to refit batteries.
Operation
1. The unit will stay “awake” for ten minutes when power is first supplied to allow
time for configuration.
2. After the unit stays in sleep status, it can be woken up by pressing the tamper
switch continuously until the LED lights up once. The unit will enter sleep status