Z-Wave Z-Box User Manual - page 27
27
The last block shows the availability of the function calls on the serial API between the Z-Wave
transceiver and Z- Way. ‘Not implemented’ means that Z-Way is either not knowing about the
function indicated by the function ID or does not make any use of it. A red function call id or
name indicated that Z-Way is able to use this function
but the transceivers firmware did not report to offer this service.
Z - Wave Terms
The following Z-Wave terms are used in this manual:
•
Static controller
is a Z-Wave device with capabilities to manage the network available on a
fixed location in the home
•
Secure environment: For sensitive applications like door lock control Z-.Wave offers an
enhanced encryption wrapping defined in the command class Security.
•
Controller Replication: Copy the information of one controller to another controller
•
SIS : The central database of nodes and ids.
•
Primary Controller: If no SIS is present one controller becomes the primary controller only
able to include new devices
•
Secondary Controller: If no SIS is present, all other controllers than the primary
controller are called secondary
•
Inclusion:
the process of bringing new Z-Wave devices into a network
•
Exclusion:
the process of removing Z-Wave devices from the network
•
Association
is a control relationship between a controlling device and a controlled device
•
Association Group is the list of devices controller by association
•
SwitchMultilevel, SwitchBinary and Basic are certain command classes
•
Node Information Frame is a special wireless message issued by a Z-Wave device
to announce its capabilities and functions.
Command Classes Controlled/Supported:
Alarm V2 Controlled, Alarm Sensor V1 Controlled , All Switch V1 Controlled, Application Status V1 Supported, Association V2
Supported and Controlled, Association Group Information V1 Supported and Controlled, Basic V1 Supported + Controlled,
Battery V1 Controlled, Binary Sensor V2 Controlled, Binary Switch V1 Controlled, Central Scene V1 Controlled, Climate Control V1,
Controlled, Clock V1 Supported and Controlled, Configuration V1 Controlled, CRC16 V1 Supported + Controlled, Device Reset