Z-Wave ZRC-100 Operating Instructions Manual

Summary of ZRC-100

  • Page 1

    1 zrc-100 (z-wave remote controller).

  • Page 2: Table of Contents

    2 table of contents introduction .................................................... 4 glossary .......................................................... 5 zrc-100 operations ....................................... 6 product overview ............................................. 7 description of f...

  • Page 3

    3 technical specifications.......................... 55 checking the accessories ......................... 56 fcc notice .................................................... 56 warnings...................................................... 56 caution ....................................................

  • Page 4: Zrc-100

    4 zrc-100 (z-wave remote controller) operating instructions introduction the zrc-100 (figure 1) is a portable z-wave remote controller with multi-channel support; also it is a z-wave enabled security controller. It can control the secured door locks when it is in the security network. Also, it can b...

  • Page 5: Glossary

    5 glossary device or node devices and nodes are all terms to describe an individual z­wave device. These are all interchangeable when setting up your z- wave network. Inclusion add a z-wave device to the network. Exclusion delete a z-wave device from the network. Remove to take a device out of a gro...

  • Page 6: Zrc-100 Operations

    6 zrc-100 operations welcome to the world of z-wave home automation, you can use your zrc-100 to control almost every z-wave certified products inside your house. The following section will guide you through the set up processes and operation procedures for your zrc-100. Please note that all z-wave ...

  • Page 7

    7 product overview figure 2 setup and control keys of zrc-100 description of function keys keys functions short cut keys for: 1. Device and scene control 2. Short cut to user selected control menu back to previous screen 4-way directional keys for setup and control ok key for confirmation short cut ...

  • Page 8

    8 zrc-100 user interface layout home (a1) device (a2) scene (a3) comfort (a4) sensor (a5) all off (a6) devices list (a2.1) scenes list (a3.1) comforts list (a4.1) sensors list (a5.1) or • press c ord keys to select control category. • press back key to go back to previous page. • press and hold back...

  • Page 9

    9 setup (b1) add device (b2) delete device (b3) add to scene (b4) device config. (b6) scene config. (b7) comfort config. (b8) sensor config. (b9) shortcut key (b10) advanced setup (b11) system settings (b12) about (b13) select scene (b4.1) device configure (b6.1) sensor configure (b9.1) shortcut key...

  • Page 10

    10 operations the zrc-100 remote controller can be set up as a primary or secondary controller within a z-wave network. The zrc-100 can control z-wave devices individually or as a group using scene or association. A single z-wave network can include 232 nodes. If necessary, more than one network can...

  • Page 11

    11 remark: z the hard keys are valid if the backlit is turned on and vise versa. User can follow the self navigated button (snb) and lcd display for all setup procedures and operation. Z user can press “ ” key to go back to the previous page or press and hold “ ” key for 2 seconds to go back to the ...

  • Page 12

    12 4 press the program button on the target device. ⇓ note 1: if you can’t add your z-wave device, this device might have been included in another z-wave network. In this case, please delete this device following the steps in the [deleting device from the network] section then add this device again....

  • Page 13

    13 2 select “delete device". 3 press key to delete the device from z-wave network. 4 press the program button on the target device. ⇓ note 1: if no ack signal received for more than 60 seconds, the “delete device” mode will exit automatically. Note 2: in a z-wave network, only the primary controller...

  • Page 14

    14 device control after adding devices to your zrc-100, you can turn the device using the corresponding device control function. Step setup key lcd indication 1 select “device"and press key to confirm. A corresponding device control page will be displayed. ⇓ 2 for on/off switches, press f key to tur...

  • Page 15

    15 4 you can turn off all the devices in the network by selecting “all off" function under the home page. ⇓ note 1: the screen will display lock /unlk if this is a secured door lock device. Note 2: you can rename your device, please refer to user manual [step of b6 - device config.]. Scene setup sce...

  • Page 16

    16 ⇓ 2 select “add to scene" and press key. 3 select a scene which you want to add the device into scene and press key. 4 press the program button on the target device. ⇓ 5 adjust the target device on/off or dim level with its program button, to the desired level. Setup add device > delete device > ...

  • Page 17

    17 note 1: your target device must be included in the network before this setup procedure, please refer to [adding device to the network] section. Note 2: if no ack signal received for more than 60 seconds, the “add device” mode will exit automatically. Removing device/end-point from a scene step se...

  • Page 18

    18 note 1: this process will only remove the target device/ep from its assigned scene but will not exclude it from the network. Note 2: if no ack signal received for more than 60 seconds, the “remove device” mode will exit automatically. Scene control after the scene setup is done, you can trigger t...

  • Page 19

    19 comfort control after adding “thermostat" or “z-wave to ac ir extender" to your zrc-100, you can change the operation mode, set target temperature and fan speed via the corresponding comfort control function. Step setup key lcd indication 1 select “comfort"and press key to confirm. A correspondin...

  • Page 20

    20 sensor information after adding “binary sensor / multi-level sensor"to your zrc-100, you can monitor the sensor temperature via the corresponding sensor function. Step setup key lcd indication 1 select “sensor"and press key to confirm. A corresponding sensor page will be displayed. ⇓ device confi...

  • Page 21

    21 2 select “device configure"and press key. 3 select your“device" and press key. 4 select your action (e.G. Move) and press key. 5 move your selected device to your target position and press to save the setting. ⇓ 6 select your action (e.G. Rename) and press key. Setup remove fr. Scene > device con...

  • Page 22

    22 7 use cdkeys to change your character and ef keys to select character position, press to save the setting. ⇓ 8 select your action (e.G. Delete) and press key. 9 press f key to confirm to delete the selected device or press e key to cancel it and go back to previous page. Note 1: zrc-100 supports ...

  • Page 23

    23 scene configure it is allow to move/rename/clear the scene after added into the scene under the scene configure function. Step setup key lcd indication 1 press and hold ef keys simultaneously for 3 seconds under the home page. ⇓ 2 select “scene configure"and press key. 3 select your“scene" and pr...

  • Page 24

    24 5 move your selected scene to your target position and press to save the setting. ⇓ 6 select your action (e.G. Rename) and press key. 7 use cdkeys to change your character and ef keys to select character position, press to save the setting. ⇓ 8 select your action (e.G. Clear) and press key. Move ...

  • Page 25

    25 9 press f key to confirm to clear the selected scene or press e key to cancel it and go back to previous page. Note 1: zrc-100 supports up to 16 characters in a row for the scene name. Note 2: this process will only remove the scene devices/eps from its assigned scene but will not exclude it from...

  • Page 26

    26 3 select your “thermostat"and press key. 4 select your action (e.G. Move) and press key. 5 move your selected thermostat to your target position and press to save the setting. ⇓ 6 select your action (e.G. Rename) and press key. 7 use cdkeys to change your character and ef keys to select character...

  • Page 27

    27 8 select your action (e.G. Delete) and press key. 9 press f key to confirm to delete the selected thermostat or press e key to cancel it and go back to previous page. Note 1: zrc-100 supports up to 16 characters in a row for the scene name. Note 2: this process will only remove the devices/eps fr...

  • Page 28

    28 2 select “shortcut key" and press key. 3 select your target shortcut key by ef keys (e.G. F1) then press key. 4 select your target device / scene / all off for your shortcut key or select your target shortcut page (comfort / sensor) for your shortcut key. 5 select a device or scene to this shortc...

  • Page 29: Z-Wave Advanced Setup

    29 z-wave advanced setup learning mode (replicating all network and device information from a primary controller to your zrc-100) your zrc-100 can: • copy the settings from another z-wave controller. • be included into existing z-wave network and act as a secondary remote controller or back to a new...

  • Page 30

    30 the primary controller user manual for more information) 5 place the two controllers close to each other. (lcd display ok if the learning mode is successful. Lcd display error if the learning mode is unsuccessful.) ⇓ l caution scene controller configuration command and association command if scen...

  • Page 31

    31 configure association (assign association for two devices) the zrc-100 can be used to assign one device to automatically interact directly with another device. For example you can assign a door sensor (primary node) to turn on the light switch (secondary node) when the door is opened. Adding devi...

  • Page 32

    32 5 assign an “assoc. Id" (e.G. 001) by using cdkeys to change your number and ef keys to select number position. Press key to save the settings. ⇓ 6 press the program/ep button on the secondary device (e.G. Light switch) ⇓ 7 press the program/ep button on the primary device (e.G. Door sensor) => i...

  • Page 33

    33 note 1: your target device must be included in the network before this setup procedure, please refer to [adding device to the network] section. Removing device/end-point from an association group step setup key lcd indication 1 press and hold ef keys simultaneously for 3 seconds under the home pa...

  • Page 34

    34 5 select an “assoc. Id" (e.G. 001) by using cdkeys to change your number and ef keys to select number position. Press key to save the settings. ⇓ 6 press the program/ep button on the secondary device (e.G. Light switch) ⇓ 7 press the program/ep button on the primary device (e.G. Door sensor) ⇓ re...

  • Page 35

    35 note 1: this process will only remove the target device/ep from its assigned association group but will not exclude it from the network. Deleting an association group step setup key lcd indication 1 press and hold ef keys simultaneously for 3 seconds under the home page. ⇓ 2 select “advanced setu...

  • Page 36

    36 5 select an “assoc. Id" (e.G. 001) by using cdkeys to change your number and ef keys to select number position. Press key to save the settings. ⇓ 6 press the program/ep button on the primary device (e.G. Door sensor) ⇓ note 1: this process will only remove the group devices/eps from its assigned ...

  • Page 37

    37 change device configuration this function is used to modify the parameter of the z-wave device via the configuration command class. Look up the parameter no. And parameter value of the target device from the device user manual before you start the below process. Step setup key lcd indication 1 pr...

  • Page 38

    38 5 use cdkeys to change your parameter value and ef keys to select number position, press to save the setting. (parameter value from - 2147483648 to +2147483647 (32bits value) 6 press the program button on the target device. ⇓ configuration parameter value +0000000000 ok to save configuration pres...

  • Page 39

    39 resetting your network you can reset your zrc-100 to clear all z-wave network and device information by the following steps: step setup key lcd indication 1 press and hold ef keys simultaneously for 3 seconds under the home page. ⇓ 2 select “advanced setup"and press key. 3 select “reset to defaul...

  • Page 40

    40 ⇓ note: after reset the remote, each device should individually perform in the section on “delete device from the network” and “add device to the network”. System settings step setup key lcd indication 1 press and hold ef keys simultaneously for 3 seconds under the home page. ⇓ 2 select “system s...

  • Page 41

    41 3 select “lcd contrast "and press key. 4 press ef keys to adjust the lcd contrast. 5 press key to save and return to previous page then select “b.L. Brightness"and press key. 6 press ef keys to adjust the backlight brightness. 7 press key to save and return to previous page then select “sleep tim...

  • Page 42

    42 about zrc-100 step setup key lcd indication 1 press and hold ef keys simultaneously for 3 seconds under the home page. ⇓ 2 select “about"and press key. It will show the firmware version on the screen. ⇓ home device > scene > comfort > ok to enter setup add device > delete device > add to scene > ...

  • Page 43: Z-Wave Network Setup

    43 z-wave network setup rediscover network (n.W.) during normal operation the network decides the best path to route signals from one device to another. If devices are moved to different positions in the installation, it is recommended to rediscover the network so the routing path will be re-configu...

  • Page 44

    44 re-scan (rediscover) devices from network in most cases, z-wave gateway is the primary controller (control center), all z-wave devices will be added / (inclusion) by the z-wave gateway. Normally, it is need to click the prog button of the z-wave device to add into the network and one by one. The ...

  • Page 45

    45 3 press f key to confirm re-scan devices or press e key to cancel it and go back to previous page. The remote will re-scan all devices from network, discovered devices will be re- assigned to their default categories (devices, comforts and sensors) names will be re- assigned in ascending order. T...

  • Page 46

    46 delete dead node from network step setup key lcd indication 1 press and hold cb keys simultaneously for 3 seconds under the home page. ⇓ 2 select “delete dead node” and press key. 3 the remote is checking the dead node. The lcd will display ok and go back to previous page when it is completed. ⇓ ...

  • Page 47

    47 4 use cb keys to select the dead node device then press key to delete it from network. ⇓ note 1: only the primary controller can be used to include or delete devices from a network. It is recommended that you mark the primary controller for each network for ease in modifying your network. Listeni...

  • Page 48

    48 3 select “listening mode” and press key. 4 the remote is entry the listening mode. (listening mode will automatically exit after 1 minute of inactivity.) note1: the mode must not be exited during communication process with another controller. Please wait for entire communication process to be com...

  • Page 49

    49 ⇓ 3 select “create a sec.” then press key. 4 please make sure the target secondary controller is setup to receive information mode. (e.G. Target secondary controller should entry the “learning mode" if this is a another zrc- 100. Please refer to the target controller user manual for more informat...

  • Page 50

    50 step setup key lcd indication 1 place the two controllers close to each other. - 2 press and hold cb keys simultaneously for 3 seconds under the home page. ⇓ 3 select “create a pri.” then press key. 4 please make sure the target primary controller is setup to receive information mode. (e.G. Targe...

  • Page 51: Wireless Information

    51 wireless information wireless range: this device has an open air line of sight transmission distance of 100 feet which complies with the z-wave standards. Performance can vary depending on the amount of objects in between z-wave devices such as walls and furniture. Every z-wave device set up in y...

  • Page 52

    52 q what can the remotec zrc-100 do for me? A a single z-wave network can include 232 nodes. If necessary, more than one network can be bridged to extend the number of nodes further, although this is normally not needed in a residential environment. The total number of controllable end-point (ep) /...

  • Page 53

    53 q can i include all z-wave devices from the network by zrc- 100 and no need to click the prog button for each device? A yes! Zrc-100 provides a useful function which is “re-scan devices” that allows rediscovering all z-wave devices from the network. Please refer to user manual with below steps: i...

  • Page 54

    54 z z-wave power strip please refer to the target device user manual for more information such as inclusion / exclusion and add end point to a scene / group. Q why do i need a different module for outdoor lighting? A the outdoor module is designed to withstand various weather conditions including h...

  • Page 55: Technical Specifications

    55 technical specifications model no. Bw8380us (zrc-100us) model no. Bw8380eu (zrc-100eu) model no. Bw8380au (zrc-100au) model no. Bw8380in (zrc-100in) rf frequency 908.4mhz (us) rf frequency 868.4mhz (eu) rf frequency 921.4mhz (au) rf frequency 865.2mhz (in) lcd fstn positive transflective 128x64 d...

  • Page 56: Checking The Accessories

    56 checking the accessories after opening the cover of the packing box, check that the following accessories are included. • zrc-100 z-wave remote controller • zrc-100 quick setup guide • zrc-100 user manual (download from our website) fcc notice this device complies with part 15 of the fcc rules. O...

  • Page 57: Caution

    57 exercise extreme caution when using z-wave devices to control appliances. Operation of the z-wave device may be in a different room then the controlled appliances, also an unintentional activation may occur if the wrong button on the remote is pressed. Z-wave devices may automatically be powered ...