Cannot carry out adding, deleting or association
1. Check to see if the battery is running out.
2. Make sure the battery is in right place.
3. Check if the wireless distance is too far
Cannot control the connected modules
TROUBLESHOOTING
3. Look for any nearby source of infrared energy that may interface.
1. Check to see if the battery is running out.
2. Check if the wireless distance is too far.
Specification for WAKEUP_INTERVAL_SET:
0x000000-0x00003B, 0x015181-0xFFFFFF, these values will be ignored.
ADVANCED FEATURE
Node Information Frame).
1. Switch a Z-Wave controller into inclusion mode.
2. Press and release the program button
ceiling sensor into learn mode(send NIF,
of ZWN-BPC will cause the
Inclusion
3. If success , red LED lit up for 5-second,and then turn off.
Note: If the ceiling sensor is not included in Z-Wave network,
button pressed.
red led will blink three time when power applied or program
Node Information Frame).
1. Switch a Z-Wave controller into exclusion mode.
2. Press and release the program button
ceiling sensor into learn mode(send NIF,
of ZWN-BPC will cause the
3. If success , red LED will turn off immediately.
Exclusion
Association
To complete Z-Wave association, please refer to your controller's
manual . Each controller has its own association method. If your
controller needs sensor to wake up, please press and hold the
program button for 2-second, then release,the ZWN-BPC will wake
up manually.
Note : Removing device from the network, the value of data will be reset.
Oct, 2016
Our company warranties this product to be free of defects in materials
and workmanship for a period of two(2) years.There are no obligations
or liabilities on the part of our company for consequential damages arising
out of, or in connection with, the use or performance of this product or
other indirect damages with respect to loss of property, revenue or
profit, or cost of removal, installation or reinstallation.
For some controller, after configuration and association setting, please
wake up ZWN-BPC manually by pressing the program button.
11036C
Manual Control
The program button on the ZWN-BPC Ceiling Mounted PIR Motion
Sensor allows the user to:
1. When the controller is in add mode, press and hold the program button
of ZWN-BPC for 2 second, and then the controller will verify the add.
2. When the controller is in remove mode, press and hold the program
button of ZWN-BPC for 2 second, and then the controller will remove
it from the current Z-Wave network.
3. Once program button is pressed and hold for 10 second, the device
will send a device reset locally notification to controller. Then clear all
the module. Use this procedure only in the event that the network
of information for the network, and restore factory defaults, and reset
Association
Grouping ID Max number of nodes Description
1 1
2. Notification Report
3
5
1. Battery Report
Lifeline:
3. Device Reset Locally
Notification
Sensor Basic rep: Basic Report
Sensor Notifi rep: Notification Report
5
2
0x00
0x00
0x07
0x08
Parameter
Size
Description
Valid Value
1 Byte
Default
NO.
Value
1
1
primary controller is missing or otherwise inoperable.
Restoring Factory Defaults
All information of network can all be restored to their factory default settings
by using your primary controller or manual reset control to reset the device.
It is minimum time when
the associated nodes
keep turn on
(n*WAKE_UP
_INTERVAL)
0x00003C Minimum value (Equal to 60 seconds)
0x015180 Maximum value (Equal to 68400 seconds, or 24 hours)
0x00003C Default value (Equal to 60 seconds, or 1 minutes)
Wakeup command class
The motion sensor will send a wakeup notification command if it has
been added into a Z-Wave network. The motion sensor will wake up
periodically(default is 1 minutes) as desired depending on time interval
Battery command class
ZWN-BPC will check the battery power level every day and report the
battery level by sending singlecast BATTERY_REPORT. When battery
1. Check to see if the battery is running out.
2. Check if the wireless distance is too far.
The sensor does not working
level is greater than 2.8V, it will send singlecast command
(BATTERY_REPORT, value 0x64). Or else when battery level
is greater than 2.6V, it will send singlecast command
(BATTERY_REPORT, value 0x10). Or else when battery level
is greater than 2.4V, it will send singlecast command
(BATTERY_REPORT, value 0x00). Or else when battery level
is less than 2.4V, it will send singlecast command
(BATTERY_REPORT, value 0xFF).User needs to replace new
batteries.
4
5
Sensor Basic set: Basic Set
0x00/0xFF
Notification
V1 Alarm Type
V1 Alarm Level
Notification Type
Event
4. Short press the program button of ZWN-BPC will send a Wake Up
Notification.
Configuration command class
Configuration parameter can be used to adjust the delay time of sending
basic set off command after motion sensor sends the basic set on when
motion detected.
Exmple, if the configure parameter is 3 , the nodes of
association group 4 that have turn on ,will turn off after third times waking up.
When the Wake_Up_Internal are 5 minutes ,the minimum time of
turning on are 15 minutes.
will stay awake for 2 seconds and then go back to sleep to conserve
battery life. It will also go to sleep when receives command WAKEUP_
_NO_MORE_NOTIFICATION. The motion sensor can be woken up
manually: Once short press the program button,it will send