53
PARAMETERS
instructionbyte
will initiate a read or write operation at 8 or 16 bits on the designated register
address, for example:
checkid = anaInConfig(0x5F, 0, 9600);
// read ID and set baud rate
cmd
is the command data that configure the registers addressed by the instruction byte. Enter 0 if per-
forming a read operation.
i = anaInConfig(0x07, 0x3a, 0);
// write ref/osc reg and enable
baud
is the serial clock transfer rate of 9600 to 57,600 bps.
baud
must be set on the first call to this
function. Enter 0 in this parameter thereafter.
anaInConfig(0x00, 0x00, 9600);
// resets device and sets baud
RETURN VALUE
0 on write operations, data value on read operations.