ZALMAN Reserator XT User Manual - page 9
◈
Front Panel Display
①
Fan Speed Gage
- Displays the Fan Speed(rpm). If there is a problem, the display will flicker. If the
flickering is observed, please check if there are any mechanical or pump related
problems.
②
FND(Flexible Numeric Display) Display
- Temperature Display
Coolant Temperature(upper display)
Ambient Temperature(lower display)
- Coolant Level Sensing
If a certain quantity of coolant is unavailable, an alarm will sound and the display will
flicker. If the flickering is observed, please refill with coolant.
- Coolant Temperature Sensing
If the coolant
’
s temperature reaches 60
℃
(92
℉
) and above, an alarm will sound and
the FND Display will flicker. If the flickering is observed, please check if there are any
problems.
③
Coolant Flow Rate Gage
- Displays the coolant flow rate. If there is a problem, the display will flicker. If the
flickering is observed, please check if there are any mechanical or pump related
problems.
◈
Control Knob & Buttons
④
Control Knob
- Controls the Fan Speed(rpm) and Coolant Flow Rate.
⑤ ℃
/
℉
Button
- Sets the temperature display to Celsius(
℃
) or Fahrenheit(
℉
).
⑥
AUTO/MANUAL Button
- AUTO Mode: Automatically adjusts fan speed and coolant flow rate.
- MANUAL Mode: Allows the user to manually adjust fan speed and coolant flow rate.
⑦
LED/RESET Button
- LED On/Off: Short pressing of the button turns the displays
’
LEDs On & Off.
- RESET: Pressing the button for at least 5 seconds will reset the Reserator XT.