3. Replace the used lamp with a new lamp of the
same power and specifically designed for
household appliances (the maximum power is
shown on the lamp cover).
4. Install the lamp cover.
5. Tighten the screw to the lamp cover.
6. Connect the plug to the mains socket.
7. Open the door.
Make sure that the light comes on.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets.
Contact the Authorised Service Centre.
Installation
Warning! Refer to Safety chapters.
Location
Refer to the assembly instructions for the
installation.
To ensure best performance, install the appliance well
away from sources of heat such as radiators, boilers,
direct sunlight etc. Make sure that air can circulate
freely around the back of the cabinet.
Positioning
This appliance can be installed in a dry, well ventilated
indoor where the ambient temperature corresponds to
the climate class indicated on the rating plate of the
appliance:
Climate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
Climate
class
Ambient temperature
T
+16°C to + 43°C
Some functional problems might occur
for some types of models when
operating outside of that range. The
correct operation can only be guaranteed
within the specified temperature range. If
you have any doubts regarding where to
install the appliance, please turn to the
vendor, to our customer service or to the
nearest Authorised Service Centre.
Electrical connection
• Before plugging in, ensure that the voltage and
frequency shown on the rating plate correspond to
your domestic power supply.
• The appliance must be earthed. The power supply
cable plug is provided with a contact for this
purpose. If the domestic power supply socket is not
earthed, connect the appliance to a separate earth
in compliance with current regulations, consulting a
qualified electrician.
• The manufacturer declines all responsibility if the
above safety precautions are not observed.
• This appliance complies with the E.E.C. Directives.
Technical information
Technical data
Height
mm
815
Width
mm
596
Depth
mm
550
18