Zanussi ZMD 905 W Operating And Installation Manual - Electrical Connection
7
Electrical connection
remove the plate at the back of the oven to reach
the terminal block. Connect the brown insulated
wire to the terminal marked "L".
Connect the blue insulated wire to the terminal
marked "N".
Connect the green and yellow insulated wite to the
terminal marked
.
Tighten the cable clamps ensuring that there is no
strain on the mains terminal.
Replace the cover and tighten securing screws.
Important
After installation and connecting, the cable must
be placed so that it cannot at any point reach a
temperature of more than 50
°
C above the ambient
temperature.
Before the appliance is connected, check that the
main fuse and the domestic installation can
support the load; and that the power supply is
properly earthed.
The manufacturer disclaims any responsibility
should these safety measures not be carried out.
This appliance meets the requirements laid down
in EEC Directive No. 89/336 relating to the
suppression of radio and TV interference.
The oven designed to be connected to 240V
(50Hz) electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
Letter L
-
Live Terminal
Letter N
-
Neutral Terminal
-
Earth
THIS APPLIANCE MUST BE
EARTHED
The cable used to connect the oven to the
electrical supply should have the characteristics
indicated in the table.
If you require a direct connection to the electric
network (mains), it is necessary that you install an
omnipole switch between the appliance and the
mains, with a minimum gap of 3 mm between the
switch contacts and of a type suitable for the
required lead in compliance with the current rules.
This switch must be easily accessible to the user
on completion of the installation and must not
break the yellow and green earth cable at any
point.
In order to connect the oven it is necessary to
Models
Upper
Lower
Cable cross
oven
oven
section mm
2
Fuse
rating
rating
and type of the cable
ZMD 905 W/K 3580 W
2825 W
4.0 HO7 RR-F
30 A