SMART SYSTEMS FOR ACCESS CONTROL
Technical Specifications
System Power
• The system is powered by a 12 VDC, 7.2 Ah, sealed,
rechargeable lead-acid battery.
• The battery is charged by a 120 to 18 VAC step-down
transformer which supplies power to an integrated 1
amp charger on the Zareba gate opener control board.
• The control board is protected by one 15 amp blade-
style fuse.
• Optional Zareba Solar Panel can be used for charging
battery.
Voltage Ratings
18 VAC Transformer: 18.0 to 22.0 VAC
5 Watt Solar panel (single): 16.5 to 22.0 VDC 300 mA
10 Watt Solar panel (single): 16.5 to 22.0 VDC 600 mA
12 V Battery: 12.0 to 13.5 VDC 7.2 Ah
Charging circuit: 12.0 to 14.8 VDC
Gate Drive
• Linear actuator temperature range: -30°F to 120°F
(-34°C to 49°C)
• Powered by a 12 v VDC motor
• Load capacity up to 2000N
• Maximum opening arc of 110º. Approximate opening
time (90º): 20 seconds, depending on weight of gate.
Gate Control Panel
• Gate opener’s microprocessor-based control board is
factory set for single, pull-to-open gate installations.
• DIP switches can be adjusted for dual or push-to-open
gates to facilitate gate opener set-up.
• RF receiver tuned to 310 MHz.
• Opener length with push-pull tube fully retracted is
32.5 inches.
• Adjustable auto-close timer (OFF to 120 seconds) and
obstruction sensitivity.
• Provisions made for digital keypads, push buttons,
contact (safety edge) sensors, and non-contact (pho-
toelectric) sensors.
• Audible entrapment alarm
Important Gate Information!
Inspect the gate to ensure that it is in proper condition
for the installation of the gate opener. Take steps as
necessary to meet these requirements.
The following criteria MUST be met prior to installation:
• The gate is plumb, level, and swings freely on its
hinges.
• No wheels are attached to the gate.
• The gate moves throughout its arc without binding
or dragging on the ground.
• Gates weighing more than 250 lbs. use ball-bearing
hinges with grease fittings.
• The fence post is secured in the ground with
concrete to minimize twist or flex when the opener
is activated.
• If your gate lacks a horizontal or vertical cross mem-
ber, add one to provide a stable area for mounting
the gate bracket.
Gate Capacity Chart
Estimated number of daily cycles (one cycle = one open + one close),
when battery is being charged with a transformer and one 12-volt battery
Gate
Length
18ft
280
265
250
235
NR
NR
NR
16ft
290
275
260
245
215
NR
NR
14ft
300
285
270
255
225
NR
NR
12ft
310
295
280
265
235
205
NR
10ft
320
305
290
275
245
215
NR
4–8ft
330
315
300
285
255
225
195
50lbs
100lbs
200lbs
300lbs
500lbs
700lbs
850lbs
Gate Weight