mark left or right.
5) Enter your preferred Door Entry code (4 digit), then press ENTER key. Use UP/DOWN key
to move the flashing mark left or right.
6) Select SINGLE USER or MULTIPLE USER using UP/DOWN key, then press ENTER key.
(I) If SINGLE USER is selected, enter residence name and house no.
Note : It is necessary to assign a house no. (any 3 digit between 001 – 999) even to a
single user, otherwise pairing process (mentioned below) cannot proceed properly.
(II) If MULTIPLE USER is selected, enter all residence names and respective house
no. (any 3 digit between 001 -999)
Use UP/DOWN key can cause the flashing mark to move left or right.
Use * key to erase a wrong entry
Use # key to change the page
Use alphanumeric keys to select alphabets. Each residence name has only a maximum of
12 letters
The unit can only accept maximum 100 different house no.
After finishing programming all residence names and house no., press ENTER key to exit back
to standby mode.
Note : During programming, if no key is pressed within 60 seconds, the unit will
automatically exit back to standby mode.
Outline of manual programming steps:
Press **168
select MANUAL and enter
Enter 6 digit PIN
Use arrow keys to select character or number to change (one at a time)
Press # to go to the next page
Press enter to save and exit programming mode.
PC Programming
Install the programming software in PC with the supplied CD.
Select PC programming after entering **168. LCD will show “ PC PROGRAMMING
MODE ”
Connect the programming cable between PC Programming connector as shown in Fig 4 and the
PC USB port.
Click on the CDP-808 icon on PC and start the programming procedure.
Read from the gatestation (left icon: gatestation to PC)
Enter User name, number, channel select, ID select (only use 1-10), Door entry code, User
mode and Pin.
Click apply and then write to gatestation (right icon: PC to gatestation)
Note: It is advised to save the file for future reference