Zehnder Rittling ComfoControl Ease User Manual

Summary of ComfoControl Ease

  • Page 1

    Comfocontrol ease user manual cooling fresh air clean air heating.

  • Page 2

    2 - en all rights reserved. This documentation has been compiled with the utmost care. The publisher cannot be held liable for any damage caused as a result of missing or incorrect information in this manual..

  • Page 3: Table of Contents

    2 - en en - 3 table of contents foreword 1. Introduction and safety .................................................................................... 4 2. Use of the comfocontrol ease ......................................................................... 5 2.1. Time and date settings ............

  • Page 4: Foreword

    4 - en foreword read this manual carefully before use. This manual provides all the information required for safe and optimal operation and maintenance of the comfocontrol ease. The device is subject to continuous development and improvement. There is therefore a possibility that the comfocontrol ea...

  • Page 5

    4 - en en - 5 2. Use of the comfocontrol ease the overview below summarizes the information that will be displayed on the cc ease. Time and date actual ventilation setting (with activated extractor hood where fitted) automatic (auto) or manual ventilation (manual) signal to replace internal (i) or e...

  • Page 6

    6 - en if an extractor hood is not registered or is not supported, then the temporary high setting will be activated by a short press of the button. While the open fire programme is activated, or when an comfocool is registered, the supply and exhaust fan cannot be manually switched off. Not all cc ...

  • Page 7

    6 - en en - 7 2.2 reading and setting the comfort temperature the comfort temperature can be read, but also set to the desired indoor temperature. Based on this temperature, the comfoair will then automatically switch to free cooling using the bypass if required. Reading the comfort temperature 1. P...

  • Page 8

    8 - en setting the ventilation levels the ventilation level can also be set manually by setting this higher or lower. A total of 4 ventilation volumes/levels can be set. These are: ■ setting a ¨ absent. - use when house is unoccupied. At level a, the house is ventilated using the minimum prescribed ...

  • Page 9

    8 - en en - 9 the timer of the temporary high setting can be switched off early by pressing , or . 2.5 switching the extractor hood on/ off (optional) 1. Press . - wait until the comfoair switches to setting 3 and the symbol for the extractor hood is displayed. 2. Press “ ” to switch off the extract...

  • Page 10

    10 - en 2. Press again (second time) to switch the exhaust fan off (and to switch the supply fan on at the same time). 3. Press again (third time) to switch the supply and exhaust fans on again. Bear in mind that switching off the supply or exhaust fan will temporarily immobilize your dwelling’s bal...

  • Page 11

    10 - en en - 11 5. Press . - wait until the hours flash, e.G. “7”. 6. Select the required start time in hours using or . 7. Press . - wait until the minutes flash, e.G. “00”. 8. Select the required start time in minutes using or . 19. Press - wait until the ventilation setting flashes, e.G. “3”. 10....

  • Page 12: 3  P Menus

    12 - en accessing the p menus 1. Press and together for 2 seconds. - wait until p menu “p2” appears on the display. 2. Select the required p menu, e.G. 2, using or . 3. Press . 4. Select the required p submenu, e.G. “23”, using or . 5. Press . Entering settings in p menus the minimum and maximum val...

  • Page 13

    12 - en en - 13 menu p1 ➝ status of programmes status sub-menu description activated p10 is menu 20 currently active? Yes (1) / no (0) p11 is menu 21 currently active? Yes (1) / no (0) p12 is menu 22 currently active? Yes (1) / no (0) p13 is menu 23 currently active? Yes (1) / no (0) p14 is menu 24 ...

  • Page 14

    14 - en values time delay sub-menu description minimum maximum factory reset p23 (optional) note: only applies to systems fitted with a corded 3-position switch. Deactivation delay for ventilation setting 3. ■ if you briefly engage ventilation setting 3 ( switches to the high setting for “x” minutes...

  • Page 15

    14 - en en - 15 values time delay sub-menu description minimum maximum factory reset p27 time for the temporary high setting. ■ after pressing and holding (>2 sec.) , the comfoair switches to the high setting for “x” minutes and then switches back automatically to the normal ventilation setting. If ...

  • Page 16: 4. Warranty And Liability

    16 - en 4. Warranty and liability warranty conditions the cc ease is covered by a manufacturer’s warranty for a period of 24 months after fitting up to a maximum of 30 months after the date of manufacture. Warranty claims may only be submitted for material faults and/or construction faults arising d...

  • Page 17: 7. Malfunctions

    16 - en en - 17 demounting if you need to demount the cc ease front section, for instance for painting purposes, then follow the steps below: 1. Disconnect the comfoair from its power supply. 2. Press the cc ease front section downwards. 3. Pull the lower edge of the cc ease front section away from ...

  • Page 18

    18 - en the internal filters are included in the standard configuration of the comfoair. The external filters (optional) form part of the ducting of the ventilation system, yet do not form part of the comfoair. Cleaning or replacing filters: 1. Press until the filters malfunction disappears (min. 3 ...

  • Page 19

    18 - en en - 19.

  • Page 20

    Zehnder group nederland b.V. Lingenstraat 2 · 8028 pm · postbus 621 · 8000 ap zwolle t +31 38 429 69 11 · f +31 38 422 56 94 info@zehnder-jestorkair.Nl · www.Zehnder-jestorkair.Nl zgnl-manual_849051024, v0512, en, subject to change.