Visu 200 surgical microscope instructions for use g30-1298-en issue 2.0 printed on 09. 11. 2006.
Page 2
2 g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 key to symbols warning! The warning triangle indicates potential sources of danger which may constitute a risk of injury for the user or a health hazard. Caution: the square indicates situations which may lead to malfunctio...
Page 3: Contents
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 contents functions at a glance 5 safety 7 description 17 visu 200 surgical microscope 18 attaching the equipment 43 operation 47 preparations for use 48 procedure 53 what to do in an emergency 55 maintenance / further informa...
Page 4
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006.
Page 5: Functions At A Glance
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 functions at a glance 5 functions at a glance visu 200 surgical microscope 6.
Page 6
6 functions at a glance g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 visu 200 surgical microscope 1 resetting the x-y coupling, focus and zoom to their initial positions 2 locking the front-to-back tilt of the surgical microscope 3 adjusting the pd 4 adjustable eyecup 5...
Page 7: Safety
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 safety 7 safety directives and standards 8 notes on installation and use 9 when using a fundus imaging system (e.G. Biom ii) 12 phototoxic retinal injury in eye surgery 12 warning labels and notes 15.
Page 8
8 safety g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 the instrument described in this manual has been developed and tested in accordance with carl zeiss safety standards and with national and in- ternational regulations. A high degree of instrument safety is thus en- s...
Page 9
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 safety 9 notes on installation and use safe working order • do not operate the equipment contained in the delivery package in – explosion-risk areas, – the presence of inflammable anesthetics or volatile solvents such as alco...
Page 10
10 safety g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 • only personnel who have undergone training and instruction are al- lowed to use this instrument. It is the responsibility of the customer or institution operating the equipment to train and instruct all staff usin...
Page 11
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 safety 11 • pay special attention to warning symbols on the instrument (triangular warning signs with exclamation marks), labels and any parts such as screws or surfaces painted red. For every use of the instrument • avoid lo...
Page 12
12 safety g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 when using a fundus imaging system (e.G. Biom ii) when using a fundus imaging system (e.G. Biom ii from the company oc- ulus) which is usually installed between the surgical microscope and the patient, make sure tha...
Page 13
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 safety 13 in the following, comments on these aspects are given and a description of how carl zeiss, as a manufacturer, makes allowance for them in its in- struments. Illumination characteristics (spectral composition) studie...
Page 14
14 safety g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 this is the reason why fiber optic illumination is used in surgical micro- scopes from carl zeiss. Exposure time to light according to some publications, the phakic or aphakic eye should not be exposed to the light ...
Page 15
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 safety 15 warning labels and notes caution: observe all warning labels and notes! If any label is missing on your instrument or has become illegible, please contact us or one of our authorized representatives. We will supply ...
Page 16
16 safety g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006.
Page 17: Description
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 17 description visu 200 surgical microscope 18 intended use 18 description of the modules 18 illumination system 26 controls, displays, connections 28 hand grips (option) 36 tube and eyepieces for main microscope ...
Page 18
18 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 visu 200 surgical microscope intended use the visu 200 surgical microscope has been designed for surgical proce- dures in the field of ophthalmology, i.E. The microscope meets the special requirements of this d...
Page 19
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 19.
Page 20
20 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 2 support arm for the surgical microscope the support arm contains a tilt device, allowing the viewing direction of the surgical microscope to be adapted to the surgical field as re- quired. Use the fine tilt k...
Page 21
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 21 2 3.
Page 22
22 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 to protect the patient's eye against photo-retinitis, a retinal protection de- vice is provided. This device can be swung into the illumination beam path, if no red reflex is required. At the light source integ...
Page 23
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 23.
Page 24
24 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 4 0° assistant's microscope the assistant's microscope is an integral part of the visu 200 surgical microscope, i.E. It cannot be separated from the main microscope. The assistant sees the same image as the mai...
Page 25
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 25 4 5.
Page 26
26 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 illumination system 6° illumination you can continuously fade out the 6° illumination. This results in markedly reduced reflection from the cornea, while providing nevertheless a high- contrast, informative mic...
Page 27
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 27 1 2 3.
Page 28
28 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 controls, displays, connections 1 instrument connector 2 microscope pivot 3 x-y coupling 4 activator button – recenters the x-y coupling. – resets the focus to its initial position in the focusing range. – rese...
Page 29
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 29 1 3 4 5 6 7 8 2.
Page 30
30 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 9 dust cover 10 release buttons for the magnetic brakes of the stand only in connection with suspension systems with magnetric brakes. A second button with the same function is located on the opposite side in t...
Page 31
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 31 11 12 13 10 9.
Page 32
32 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 14 manual adjustment of zoom system 15 knob for adjusting the red reflex illumination the angle of illumination can be switched between + 2° and - 2°. 16 release button for magnetic brakes (a second button with...
Page 33
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 33 14 15 16 17 18 19 20 21.
Page 34
34 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 22 light stop knob 23 adjusting lever for the 6° illumination for gradual fading in/out of the coaxial illumination. Fading out the 6° illumination improves the visualization of structures in retro-illumina- ti...
Page 35
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 35 22 23 25 24.
Page 36
36 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 hand grips (option) in addition to the maneuvering grips provided, larger hand grips can be mounted. The mounting procedure is described in the instructions en- closed. This does not affect the functioning of t...
Page 37
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 37 1 2 1.
Page 38
38 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 tube and eyepieces for main microscope 1 180° tiltable tube 2 pd adjustment knob the correct interpupillary distance has been set when both eyepiece images merge into one. 3 push-in widefield eyepiece note: whe...
Page 39
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 39 1 2 4 5 6 3.
Page 40
40 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 tube and eyepieces for assistant's microscope 7 push-in widefield eyepiece note: when you remove the eyepiece from the tube, please note that this eyepiece is fitted with a magnetic coupling. When mounted, the ...
Page 41
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 description 41 7 8 9 10 11.
Page 42
42 description g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006.
Page 43: Attaching The Equipment
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 attaching the equipment 43 attaching the equipment mounting the binocular tubes, eyepieces and the objective lens 44.
Page 44
44 attaching the equipment g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 mounting the binocular tubes, eyepieces and the objective lens note: always use the assistant's microscope with the appropriate binocular as- sistant's tube (shown). If you use a different tube, you...
Page 45
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 attaching the equipment 45 caution: before using and after re-equipping the unit, make sure that the two bin- ocular tubes (2 and 10) are securely locked in position. Make sure that – securing screws (5 and 7) and – objective...
Page 46
46 attaching the equipment g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006.
Page 47: Operation
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 operation 47 operation preparations for use 48 adjusting the tilt angle 48 adjusting the surgical microscope 49 checklist 50 when using a fundus imaging system (e.G. Biom ii) 52 procedure 53 what to do in an emergency 55 fail...
Page 48: Preparations For Use
48 operation g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 preparations for use adjusting the tilt angle using knob (1), you can position the surgical microscope in a range from + 15° to - 90° (+ 15° in the direction of the surgeon and - 90° in the oppo- site direction)....
Page 49
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 operation 49 adjusting the surgical microscope bring the surgical microscope into starting position within the focusing range. Set the minimum magnification on the surgical micros- cope. Bring the surgical microscope into wor...
Page 50
50 operation g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 checklist always check the following points before surgery (without the patient!): visu 200 surgical microscope – check that the correct rated voltage has been set for the suspension system. – check that all cabl...
Page 51
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 operation 51 – check that image quality is the same throughout the entire magnifica- tion range. Accessories – using the relevant user's manuals, check that the other equipment (il- lumination system, video system, etc.) is w...
Page 52
52 operation g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 when using a fundus imaging system (e.G. Biom ii) when using a fundus imaging system (e.G. Biom ii from the company oc- ulus) which is usually installed between the surgical microscope and the patient, make sure ...
Page 53: Procedure
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 operation 53 procedure • turn on the power switch of the suspension system. • adjust the brightness of the surgical field illumination as required on the stand. • check the unit using the checklist. • move the surgical micros...
Page 54
54 operation g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 caution! – avoid looking directly into the light source, e.G. Into the microscope ob- jective lens or into a fiber light guide! – when selecting the brightness level for the patient's eye, always take care to kee...
Page 55
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 operation 55 what to do in an emergency failure of zoom system • manually adjust the magnification using zoom control (1) on the micro- scope (if necessary, use a tool, e.G. Screwdriver, coin, etc.). 1.
Page 56
56 operation g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 failure of x-y coupling • if the x-y coupling fails, you can manually position the surgical micro- scope utilizing the possibilities of the suspension system you are us- ing. Failure of focusing system • disconne...
Page 57
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 maintenance / further information 57 maintenance / further information trouble-shooting 58 magnifications / fields of view 60 care of the unit 61 sterilization 62 ordering data 63 spare parts 64 accessories 64 adapter cables ...
Page 58
58 maintenance / further information g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 trouble-shooting • this instrument is a high-grade technological product. To ensure opti- mum performance and safe working order of the instrument, its safety must be checked once every 12...
Page 59
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 maintenance / further information 59 insufficient surgical field illu- mination. Brightness level set too low. Adjust brightness on sus- pension system or using foot control panel. - defective s light guide (no homogeneous il...
Page 60
60 maintenance / further information g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 magnifications / fields of view using the magnification factor γ of the zoom system, you can calculate the total magnification of the surgical microscope according to the following formula...
Page 61
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 maintenance / further information 61 care of the unit cleaning optical surfaces the multilayer t* (t-star) coating of our optical components (e.G. Eye- pieces, objective lenses) results in optimum image quality. Image quality...
Page 62
62 maintenance / further information g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 sterilization the asepsis sets supplied by carl zeiss contain rubber caps, sleeves and hand grips which can be sterilized in autoclaves. We recommend the fol- lowing program for sterilizat...
Page 63
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 maintenance / further information 63 ordering data visu 200 surgical microscope description cat. No. Visu 200 surgical microscope including x-y coupling and assistant's microscope 1050-462 180° tiltable tube 30 37 91-0000 10x...
Page 64
64 maintenance / further information g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 spare parts visu 200 surgical microscope accessories please observe the following: only operate the instrument with the accessories included in the delivery package. If you want to use oth...
Page 65
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 maintenance / further information 65 visu 200 surgical microscope description cat. No. 1 objective lens, f = 200 mm 30 26 52-9903 2 optical wedge, 30° 1006-145 3 sleeve (for insertion of eyepiece (4)) 30 55 42-0107 4 10x eyep...
Page 66
66 maintenance / further information g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 adapter cables for the electrical connection of the surgical microscope to different types of suspension system. Cat. No. 1 emd ii electromechanical ceiling mount 30 26 02- 9053 1 s3 ceili...
Page 67
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 maintenance / further information 67 technical data visu 200 surgical microscope optical data magnification main microscope: 4.9x - 29x motorized zoom system with apochromatic op- tics, 1:6 zoom ratio, magnification factor γ ...
Page 68
68 maintenance / further information g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 mechanical data swing-in stops patented retinal protection device, pat. No. De 33 39 17 2 c2 patented field stop for reduced glare, pat. No. G 91 03 43 3.7 microscope tilt with torque comp...
Page 69
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 maintenance / further information 69 ambient requirements subject to change. For operation temperature rel. Humidity air pressure +10 °c...+40 °c 30%...75% 700 hpa...1,060 hpa for transportation and storage temperature rel. H...
Page 70
70 maintenance / further information g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006.
Page 71: Index
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 index 71 index numerics 0° assistant's microscope 24 2° illumination 26 90° position 48 a accessories 64 accident prevention regulations 8 activator button 28 adapter cables 66 adjusting lever for 6° illumination 34 adjusting...
Page 72
72 index g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 failure of zoom system 55 fields of view 60 focus of the light source 13 focusing knob 32 focusing system failure 56 fogging, prevention 61 fundus imaging system 12, 52 g gg 475 eye protection filter 14 gg 475 protec...
Page 73
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 index 73 p pd adjustment knob 38 phototoxic retinal injury in eye surgery 12 potential equalization 9 prevention of fogging 61 procedure 53 protective ground contact 10 q quality management system 8 r red reflex illumination ...
Page 74
74 index g30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006.
Page 75
G30-1298-en visu 200 surgical microscope issue 2.0 printed on 09. 11. 2006 75.
Page 76
Carl zeiss surgical products division 73446 oberkochen germany fax: +49 (0) 7364/20-4823 email: surgical@zeiss.De www.Zeiss.De g30-1298-en printed in germany ms-td.