    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 1 of 36 hydrotap g4 installation instructions affix model number label here 802253nz filtered boiling and chilled drinking water for residential use. ®.

  • Page 2

    Page 2 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 hydrotap specifications installation check list .................................................................................................................... 3 general product features ...............

  • Page 3

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 3 of 36 before installation: a. Read the instructions and check if there is adequate space to mount all of the components. B. Note: not all fittings are supplied with the appliance kit. Isolation valves are not ...

  • Page 4

    Page 4 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 thank you for purchasing a zenith hydrotap. Please read and follow these instructions carefully to ensure safe and trouble free service. If service is required, please call 0800 558055 what is the zenith ...

  • Page 5

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 5 of 36 important safety instructions this manual contains important safety, installation instructions for the zenith hydrotap g4. Safety this appliance is not intended for use by persons (including children) wi...

  • Page 6

    Page 6 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 important safety instructions warnings 1. The zenith hydrotap unit must be earthed. The resistance of the earth connection from each exposed metal part must be less than 1 ohm. 2. All installation and ser...

  • Page 7

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 7 of 36 major components and accessories parts supplied description 1 x tap option with hoses (classic tap shown) 1 x hydrotap undersink unit with air and water filters 1 x mains water connection hose vent kit 1...

  • Page 8

    Page 8 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 technical specifications ** add an extra 5 kg when full of water gpo's required power rating (kw) boost rating (kw) unit dimensions w x d x h (mm) with air duct **dry weight (kg) boiling chilled bc 1x10a ...

  • Page 9

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 9 of 36 before installation before installing ensure that the following have been provided at the installation site: • review all the technical specifications. • ensure the underbench can support the product wei...

  • Page 10: Section 1

    Page 10 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 hole positioning: position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot. Alternatively, the tap could be mounted away from the sink using a zenith font, ava...

  • Page 11: 1.2

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 11 of 36 apply a light smearing of silicon sealant on the underside of the spacer to ensure a watertight fit. 1.2 cut a 35mm hole in the bench / sink top. Bench top 1.1 Ø35mm all thread rod stainless steel space...

  • Page 12: 1.3

    Page 12 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 black plastic spacer 1.3 installation instructions pass all the hoses, tubes and usb lead through the 35mm hole. 1.4 35mm hole note: feed each of the three tubes and electrical cable evenly in between th...

  • Page 13: Hydrotap Arc/cube

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 13 of 36 hydrotap arc/cube the hydrotap arc/cube has a spout that may be fixed in one of 6 angular positions (depending on the position of the rotary control) and fixed in one of two height positions. The spout ...

  • Page 14: 1.7

    Page 14 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 installation instructions a a left hand control right hand control b c c b 50mm height adjustment (fixed position options) angular adjustment (fixed position options) 1.7 o-ring lower rubber washer washe...

  • Page 15: 1.10

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 15 of 36 cut a 35mm hole in the bench / sink top. Sink top 1.10 35mm note : make sure the tap location will allow the nozzle to drain into the sink. Tap assembly exploded view and kitchen layout side view. Braid...

  • Page 16: 1.12

    Page 16 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 1.12 installing the mixer tap (classic, arc and cube) installation instructions sink top o-ring lower seal washer securing nut mixer tap arc mixer tap • fit the o-ring into the recess on the underside of...

  • Page 17: 1.13

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 17 of 36 installation instructions cold isolation valve (not supplied) restrictafl ow valve & tee (supplied) red cle a r blue br a ided power cord usb mains in mixer out mixer in boiling out bypass in vent bypass...

  • Page 18: 1.14

    Page 18 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 cut a 50mm hole in the bench / sink top. Sink top 1.14 50mm note: make sure the tap location will allow the nozzle to drain into the sink. (see page 11) all-in-one tap installation min 300mm 335mm 470mm ...

  • Page 19: 1.16

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 19 of 36 installation instructions fixing nut 1.16 1.17 clamp block o-ring aio vented assy blue to chiller connection clear to vent red to boiling connection from mixer out aio mains assy blue mark white mark bl...

  • Page 20: 1.18

    Page 20 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 1.18 installation instructions clamp block • screw the braided hoses into the extension tubes. Ensure the o-rings are lubricated prior to assembly and that the braided hoses, with coloured markings, are ...

  • Page 21: 1.20

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 21 of 36 installation instructions 1.20 typical all-in-one vented assembly with booster heater (see section 3) booster cold isolation valve (not supplied) restrictafl ow valve & tee (supplied) restrictaflow valve...

  • Page 22: 2.1

    Page 22 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 2.1 ventilation for all models proper air circulation must be provided for all boiling and chilled models. The system will operate correctly only if the recommended air gaps are achieved during installat...

  • Page 23: 2.2

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 23 of 36 when installing air flow ducts, the following tools will be required: • jigsaw and 12mm drill • keyhole or wall board saw. Ventilation cool air in warm air out air inlet vent position airflow through th...

  • Page 24

    Page 24 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 typical cut out procedure for b ventilation cutout deatils air inlet vent 1. Mark out and cut the air inlet and door outlet holes as shown 2. Ensure the air inlet vent and air outlet vent are positioned ...

  • Page 25: Section 3

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 25 of 36 section 3 booster heater mount base horizontally 3.1 product description the boost unit is a compact electronically controlled auxillary water heater. It is intended to provide pre heating of water befo...

  • Page 26: 3.2

    Page 26 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 booster installation 3.2 installation procedure site requirements • appliance must only be installed in a frost-free area. Never expose appliance to frost. • the appliance is designed for wall mounted in...

  • Page 27: 3.4

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 27 of 36 note1: this appliance is intended for use with the zenith hydrotap under sink unit. Note2: water connections must be pointing vertically upwards. Note3: the booster unit should be installed as close as ...

  • Page 28: 4.1

    Page 28 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 if an external filter is installed, select position b b rotate 90° only 1 2 3 4 check the table below to determine which filter bypass position you need for your product. Note: before you install a unit,...

  • Page 29: 4.3

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 29 of 36 4.3 model: boiling chilled installation instructions : not required for standard bc hydrotap models. Min. 50mm clearance 280mm red cle a r blue br a ided max. 1000mm max. 500mm power cord usb mains in m...

  • Page 30: 4.4

    Page 30 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 installation instructions external hot and cold isolation valves (not supplied) tee piece (supplied) 4.4 model: all-in-one mains pressure red cle a r blue br a ided power cord usb mains in mixer out mixe...

  • Page 31: 4.5

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 31 of 36 note: to activate the filter, flush at least 10l of water through the filter before connecting to a softener or to a booster heater. Installation instructions 4.5 model: all-in-one vented tee piece and ...

  • Page 32: 4.6

    Page 32 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 installation instructions cold isolation valve (not supplied) restrictafl ow valve (supplied) tee piece (supplied) red cle a r blue br a ided power cord usb mains in mixer out mixer in boiling out bypass ...

  • Page 33: 5.2

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 33 of 36 • turn on the water and check for any leaks. • turn the power on at the gpo and at the side of the undersink unit • if fitted, ensure the booster is turned off. (the booster is commissioned, later, at s...

  • Page 34: 5.4

    Page 34 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 5.4 - boiling calibration commissioning 5.5 - booster • press the calibration button and the system will commence the boiling calibration procedure. This will take aprox 5-6 minutes. • upon completion, a...

  • Page 35

    802253nz - hydrotap bc, bcha -av, aio, installation instructions - aug 2015 - v2.01 page 35 of 36 trouble shooting system fault message possible cause solutions power board fault electrical disruption check power supply and all fuses interface fault internal fault call zenith service level board fau...

  • Page 36

    Page 36 of 36 802253nz - hydrotap bc, bcha-av, aio, installation instructions - aug 2015 - v2.01 end of life disposal in order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local city council for collection centre details. Contact details the...