Zenith HydroTap G4 User Manual - Contact Details

Other manuals for HydroTap G4: User Manual, Installation Instructions Manual
Manual is about: Filtered boiling and chilled drinking water for residential use

Summary of HydroTap G4

  • Page 1

    801981nz - cs user guide - aug 2015 v2.00 page 1 of 24 hydrotap g4 user guide ® • tap operation..................(pages 2-8) • lcd screen & menu .......(pages 9-19) • maintenance.................... (pages 19-22) date of installation............./........../........... Affix model number label here ...

  • Page 2: Elite Tap:

    Page 2 of 24 801981nz - cs user guide - aug 2015 - v2.00 elite tap: the elite tap uses touch sensitive controls, to dispense chilled and chilled sparkling water. When operating the tap, ensure the touch surface is dry as moisture may interfere with the sensor touch control. 3. Tap functions hydrotap...

  • Page 3: Tap Functions

    801981nz - cs user guide - aug 2015 v2.00 page 3 of 24 3. Tap functions all-in-one tap: the top of the all-in-one tap is operated the same as a classic hydrotap. The two levers are used for dispensing chilled and chilled sparkling water. The mixer tap lever is operated as a classic ‘flick mixer’. Th...

  • Page 4: Tap Functions

    801981nz - cs user guide - aug 2015 v2.00 page 4 of 24 on powerup, wait 30secs. For the unit to calibrate. Tapping the select button will allow the selection of either the chilled (blue) or sparkling (white) water mode. The arc/cube control may be rotated in a forward or reverse direction to dispens...

  • Page 5: Tap Operation

    801981nz - cs user guide - aug 2015 - v2.00 page 5 of 24 arc/cube tap 3. Tap operation elite tap: touching the chilled button allows the dispensing of chilled water. Elite tap indicator light to dispense chilled water: (classic and aio taps) hydrotap arc/cube: if not showing blue, tap the select but...

  • Page 6: Tap Operation

    Page 6 of 24 801981nz - cs user guide - aug 2015 - v2.00 tap operation hydrotap arc/cube: if showing blue, tap the select button until the indicator light turns white. Rotating the control , when the indicator light is white, will allow the dispensing of sparkling water. When unattended, the control...

  • Page 7: Tap Lights

    801981nz - cs user guide - aug 2015 - v2.00 page 7 of 24 tap lights filter light: (classic, elite & aio taps) filter change light off: this indicates the filter is operating within its normal specified lifespan. Filter change light flashing slowly: the light will flash slowly when the filter is due ...

  • Page 8: Filter Light:

    Page 8 of 24 801981nz - cs user guide - aug 2015 - v2.00 filter light: hydrotap arc/cube: flashing filter lights: all three tap lights (safety; select and indicator light) will flash every 10 seconds, indicating a filter change is required. Safety light indicator light select light warning: (all) fl...

  • Page 9: Lcd Screen

    801981nz - cs user guide - aug 2015 - v2.00 page 9 of 24 note: when selecting menu options, the screen will revert to the main menu, if the screen remains inactive for a period, in excess of 10 seconds. Zenith hydrotap g4 introduces a ‘touch’ screen for easy setup and operation adjustment. Other pos...

  • Page 10: Lcd Screen Menu

    Page 10 of 24 801981nz - cs user guide - aug 2015 - v2.00 3 lcd screen menu main menu sub menu sub menu options section language • english a • product info • system faults • event log • product serial no. • lists b information installation • filter flush • filter reset • purge co 2 • lux sensor • re...

  • Page 11

    801981nz - cs user guide - aug 2015 - v2.00 page 11 of 24 a set language b system information in this section, you can find product information, system faults and filter log messages. Lcd screen operation - section a lcd screen operation - section b 1. Press [product info] to view the current produc...

  • Page 12: C           Install

    Page 12 of 24 801981nz - cs user guide - aug 2015 - v2.00 c install have a bucket or similar container (not supplied) at the ready to hold a quantity of water that will be ejected while the filter flush mode is in operation. Open the filter access door on the front of the hydrotap and the filter car...

  • Page 13: 2 - Filter Reset

    801981nz - cs user guide - aug 2015 - v2.00 page 13 of 24 1. Press the [menu] button for main menu. 2. Press the [install] button. 3. Press the [filter reset] button. 4. In the next screen, press [yes] button if you want to flush the filter. Follow the filter flush steps to start filter flush or pre...

  • Page 14: E            Security

    Page 14 of 24 801981nz - cs user guide - aug 2015 - v2.00 this section is reserved for service technicians only note : in australia call a licensed electrician, plumber,or zenith office on 1800-638-633, for assistance, service, spare parts, or enquiries. D service lcd screen operation - section d e ...

  • Page 15: Settings

    801981nz - cs user guide - aug 2015 - v2.00 page 15 of 24 g settings 3. Lcd screen operation - section g g i nstructions 1. Press the [menu] button for main menu. 2. Press the [settings] button. 3. Press [enable password]. 4. Then enter your 4-digit password. You will need to enter your password to ...

  • Page 16: Filter

    Page 16 of 24 801981nz - cs user guide - aug 2015 - v2.00 3. Lcd screen operation - section g t ions to edit the filter life: 1. Press [menu] button for main menu. 2. Press [setting] button. 3. Press [filter] button. 4. Press [filter life] button, for internal or external filter. 5. To change filter...

  • Page 17: Energy Modes

    801981nz - cs user guide - aug 2015 - v2.00 page 17 of 24 lcd screen operation - section g sleep mode light level time delay state chiller 2 hours-> off n/a 2 hr off off lux sensor-> off dark n/a off off lux or 2 hr-> off dark 2 hr off off disable n/a n/a on on this mode allows the hydrotap to enter...

  • Page 18

    Page 18 of 24 801981nz - cs user guide - aug 2015 - v2.00 lcd screen operation - section g to activate on/off mode: 1. Press the [menu] button for main menu. 2. Press the [setting] button. 3. If required, enter your 4 digit password 4. Press the [energy modes] button. 5. Select ‘individual set’ if y...

  • Page 19: To Change The Filter:

    801981nz - cs user guide - aug 2015 - v2.00 page 19 of 24 to change the filter: (see also section c) • open the door of the under sink unit. • relieve system pressure via the filter flush stop cock, a quick open and close will do. Use the bucket to catch the discharge. • grasp filter cartridge, depr...

  • Page 20: Filter Maintenance

    Page 20 of 24 801981nz - cs user guide - aug 2015 - v2.00 filter maintenance air inlet filter the zenith hydrotap air filter is conveniently located on the outside of the condenser. The filter screen is a sliding fit in the plastic housing on the side of the under sink unit. The screen may be remove...

  • Page 21: Gas Bottle Change

    801981nz - cs user guide - aug 2015 - v2.00 page 21 of 24 gas bottle change 1. Turn the co 2 bottle, main control wheel, off (clockwise). 2. Turn the regulator, grey control knob, all the way out (anti clockwise). 3. Dispense sparkling water for 30 seconds, until the water flow is free of gas 4. Rem...

  • Page 22: Cleaning

    Page 22 of 24 801981nz - cs user guide - aug 2015 - v2.00 cleaning general cleaning do not use strong, corrosive, spray or abrasive cleaners. Clean with a soft damp cloth and mild soap. Under sink units must never be located near, or cleaned with water jets. Avoid using airborne pesticides near the ...

  • Page 23: Home Menu Icons

    801981nz - cs user guide - aug 2015 - v2.00 page 23 of 24 home menu icons sleep mode is active. There are 3 sleep mode options which display this icon on the home screen. See page 17 for details. Filter use. This icon displays the filter usage remaining from 100% (new filter) to 0% (end of life). Wh...

  • Page 24: Contact Details

    Page 24 of 24 801981nz - cs user guide - aug 2015 - v2.00 the terms “zenith” and “hydrotap” are registered trade marks of zip heaters (aust) pty ltd. Zenith products described in this publication are manufactured under one or more of the following patents: au675601, au637412, au635979, gb0422305, gb...