2easy DT-597 Manual

Manual is about: Door Station 2-wire series

Summary of DT-597

  • Page 1

    Www.Intelligenthomeonline.Com door station model dt-597 www .Intelligenthomeonline.Com 2-wire series.

  • Page 2: Introduction

    Introduction this door station is equipped with a high resolution colour ccd camera sensor with wide angle of view 105 degrees. White leds enable the door station to work ef ciently at night. The door station facia is made of medical stainless steel 2.5 mm for better protection against vandalism and...

  • Page 3: Door Station Mounting

    Lock control jumper : to program electric lock type door station code dip : to program address for up to 4 x door stations t/r+,t/r- : usb-rs485 communication terminal main connect port : to connect the bus line and electric locks (up to 2) bus : connect to the bus line, no-polarity pl : additional ...

  • Page 4: Rep

    Rep lacing name label 90° open close 1 2 3 system wiring and connections bus pl s1+ s2+ s- - + monitor ac~ pc6 1-monitor kit connection steps: 1. Use the special spanner and move it 90 0 to loosen the screw 2. Open the front panel 3. Insert the new label -4-.

  • Page 5

    Multi door stations connection 85~260vac monitors bus pl s1+ s2+ s- bus pl s1+ s2+ s- bus pl s1+ s2+ s- bus pl s1+ s2+ s- 1 2 on 1 2 on 1 2 on 1 2 on 1# camera id=00 id=10 id=01 id=11 2# camera 3# camera 4# camera dbc-4a a b c d off on impedance switch ac~ pc6 multi monitors connection via daisy cha...

  • Page 6: (Models Cronus, Leda)

    Multi monitor connection via star with distributor dbc-4 (models cronus, leda) 1 2 3 4 5 6 on 1 2 3 4 5 6 on code=3, dip-6=on code=1, dip-6=on 1 2 3 4 5 6 on 1 2 3 4 5 6 on code=2, dip-6=on code=0, dip-6=on code=15, dip-6=on code=13, dip-6=on code=14, dip-6=on code=12, dip-6=on off on off on monitor...

  • Page 7: Electric Lock Connection

    Electric lock connection connect one lock connect two locks up to 2 electric or magnetic locks can be connected and open independently. Note: both locks must be the same type, i.E. 2 x ‘power-on-to-unlock’ or 2 x ‘power-off-to-unlock’ lock/s can be powered from door station if: 1. Electric lock is ‘...

  • Page 8

    Lock take off the jumper power supply lock take off the jumper power supply lock bus pl s1+ s2+ s- bus pl s1+ s2+ s- connect one lock connect two locks 5.2.3 ‘unlock mode’ parameter and unlocking time programming via monitor 1.Touch icon 2.Touch the screen and hold for 2s 3.Touch installer setup ico...

  • Page 9: Door Station

    Door station dip switches 2 x dip switches used to set the address of door station if more than one connected into the system on(1) = off(0) = on on settings can be done either before or after installation there are 6 x dip switches on the rear of video monitor and they are used to configure the ‘us...

  • Page 10: Specifications

    Dip state user code code=0 code=1 code=2 code=3 code=4 code=6 code=7 code=8 code=9 code=10 code=11 code=12 code=13 code=14 code=15 code=5 dip state user code dip state user code 1 2 3 4 5 6 on 1 2 3 4 5 6 on 1 2 3 4 5 6 on 1 2 3 4 5 6 on 1 2 3 4 5 6 on 1 2 3 4 5 6 on 1 2 3 4 5 6 on 1 2 3 4 5 6 on 1 ...

  • Page 11: Cables Requirements

    Cables requirements this system transmits video and audio through the power cable. No polarity connection. Recommended cables uncreened: twisted pair, flex multi-cores, speaker cable, cat5/cat6. Minimum requirements 0.5mm cable up to 2mm (depends on distance) b a c dbc-4 monitor monitor monitor two ...

  • Page 12

    The design and specifications can be changed without notice to the user right to interpret and copyright of this manual are preserved www.Intelligenthomeonline.Com.