2easy DT-597 Manual - Electric Lock Connection
Electric Lock Connection
Connect one Lock
Connect two Locks
Up to 2 Electric or Magnetic locks can be connected and open independently.
NOTE: both locks must be the same type, i.e.
2 x ‘Power-on-to-unlock’ or 2 x ‘Power-off-to-unlock’
Lock/s can be powered from door station if:
1. Electric lock is ‘Power-on-to-unlock’
2. The lock is 12V, and holding current is less than 250mA
NOTE: Exit Button is not timed
The ‘Unlock Mode’ parameter would be 0 (default, no need extra programming)
EB
*
LOCK
LOCK
2
nd
1
ST
2
nd
EB
*
1
ST
Jumper position in
Connect two locks
2-3
1 2 3
BUS
PL
S1+ S2+ S-
EB
*
LOCK
BUS
PL
S1+ S2+ S-
Jumper position in
Connect one lock
2-3
1 2 3
Automated Gates and Magnetic Locks
1. Connect low voltage box of the gates according diagram below
2. Additional power supply for Magnetic lock/s according lock specs
The ‘Unlock Mode’ parameter for ‘Power-on-to-unlock’ would be 0 (default, no need extra
programming)
The ‘Unlock Mode’ parameter for ‘Power-off-to-unlock’ would be 1 (needs extra
programming via monitor ‘Installer Setup’)
-7-