2N Helios IP Force Installation Manual

Other manuals for Helios IP Force: Installation Manual, Installation Manual
Manual is about: Security IP Intercom

Summary of Helios IP Force

  • Page 1

    2n ® helios ip force door access intercom installation manual version 1.0.0 www.2n.Cz.

  • Page 2

    The 2n telekomunikace a.S. Joint-stock company is a czech manufacturer and supplier of telecommunications equipment. The product family developed by 2n telekomunikace a.S. Includes intercoms, gsm and umts products, private branch exchanges (pbxs) and m2m solution. 2n telekomunikace a.S. Has been ran...

  • Page 3: Contents

    Contents 1. Product overview............................................................... 5 1.1 product description ....................................................................................................... 7 basic features.................................................................

  • Page 4

    3. Function and use ............................................................. 29 3.1 2n ® helios ip force configuration ............................................................................. 31 3.2 2n ® helios ip force control .................................................................

  • Page 5: Product

    5 1 1. Product overview in this section, we introduce the 2n ® helios ip force product, outline its application options and highlight the advantages following from its use. Here is what you can find in this section: product description upgrade 2n ® helios ip force components and associated products ...

  • Page 7: 1.1  Product Description

    7 1.1 product description basic features 2n ® helios ip force is a highly resistant and reliable ip door access intercom provided with a lot of useful above-standard functions. Supporting the sip standard and being compatible with the leading ip pbx and telephone suppliers, 2n ® helios ip force can ...

  • Page 8: Advantages of Use

    8 advantages of use uncompromising antivandal design high covering level – up to class ip69 variable mounting options (brick/plasterboard flush mounting, surface mounting) sensitive microphone and powerful loudspeaker bidirectional communication – acoustic echo cancelling integrated colour camera wi...

  • Page 9: 1.2  Upgrade

    9 1.2 upgrade the manufacturer reserves the right to modify the product in order to improve its qualities. Version changes.

  • Page 10: 1.3  2N

    10 1.3 2n ® helios ip force components and associated products basic units 9151101 1 button 9151101c 1 button with camera 9151101w 1 button, 10w loudspeaker, ip69 9151101cw 1 button with camera, 10w loudspeaker, ip69 9151104 4 buttons 9151104c 4 buttons with camera 9151101k 1 button with keypad 9151...

  • Page 11: Flush Mounting Box

    11 flush mounting box 9151001 brick flush mounting box 9151002 plasterboard flush mounting box gsm / umts connection accessories 505004 2n ® voiceblue lite 505214 2n ® voiceblue enterprise 505612 2n ® umts office route.

  • Page 12: Electric Locks

    12 voip connection accessories 91378100 poe injector 91378300 grandstream voip telephone 91378350 grandstream voip video telephone electric locks 932070 befo 1211 12v / 600 ma 932080 befo 1221 with momentary pin 932090 befo 1211mb with mechanical blocking other accesories 91341481e 12 v/2 a adapter ...

  • Page 13: 1.4  Terms And Symbols

    13 1.4 terms and symbols symbols safety warning always abide by this information to prevent injury of persons! Warning  always abide by this information to prevent damage to the device. Caution important information for system functionality. Tip useful advice. Note additional information..

  • Page 14: Description and

    14 2 2. Description and installation in this section we describe the 2n ® helios ip force product and its installation. Here is what you can find in this section: before you start mechanical installation button tags – insertion and replacement electric installation.

  • Page 15: 2.1  Before You Start

    Before you start 2.1 15 2.1 before you start product completeness check please check the contents of your 2n ® helios ip force delivery: 1 2n ® helios ip force (selected model) 1 frame (of the corresponding colour) 1 torx 10 / torx 20 double-ended wrench bushings (enclosed): 1 big two-hole sealed bu...

  • Page 16: Mounting Type Overview

    Mechanical installation 2.2 16 2.2 mechanical installation mounting type overview refer to the table below for a list of mounting types and necessary components. Flush mounting – classic bricks what you need: a precisely cut hole or, optionally, the brick flush mounting box, part no. 9151001 flush m...

  • Page 17

    Mechanical installation 2.2 17 flush mounting – plasterboard wall what you need: plasterboard flush mounting box, part no. 9151002 wall mounting (concrete and steel structures, entry barrier columns, etc.) what you need: just your 2n ® helios ip force unit (the covering frame is not applied) caution...

  • Page 18: Common Mounting Principles

    Mechanical installation 2.2 18 common mounting principles tips select flush mounting where possible to make your product elegant looking, more vandal resistant and more secure. You can purchase the flush mounting box in advance and hire an installation professional to make the basic installation wor...

  • Page 19: Flush Mounting

    Mechanical installation 2.2 19 flush mounting – classic bricks if you use the brick flush mounting box, follow the instructions included in the box. If you do not use the mounting box, follow the instructions below: 1. Make a hole using the template. Suppose that all the required cables have been ca...

  • Page 20: Flush Mounting

    Mechanical installation 2.2 20 flush mounting – thermally insulated wall cut out the thermal insulation layer using the template (the same as for classic brick wall). Caution the hole depth depends on the insulation layer thickness. If the insulation layer is rather thick, you may need longer screws...

  • Page 21: Flush Mounting

    Mechanical installation 2.2 21 flush mounting – hollow bricks suppose you intend to install your 2n ® helios ip force unit into a wall made of hollow bricks. Note that the external side of the bricks gets damaged by cutting and the dowels cannot practically be fixed into the thin internal part of th...

  • Page 22: Wall Mounting

    Mechanical installation 2.2 22 wall mounting wall (surface) mounting is used where flush mounting is inapplicable (in concrete and steel structures, entry barrier columns, etc.). The frame is not used. Caution wall mounting may be a problem where vandals may destroy the unit (in public garages, e.G....

  • Page 23: Use Of Cable Bushings

    Mechanical installation 2.2 23 use of cable bushings the cable bushings included in the 2n ® helios ip force delivery are designed for the following cables: big bushing: for two cables of the diameter of 5–6 mm (utp cable), or, upon insert replacement, for one thick cable/tube of the diameter of up ...

  • Page 24: Pcb Connectors

    Electric installation 2.3 24 2.3 electric installation this subsection describes how to connect 2n ® helios ip force into your local area network (lan) and how to connect supply voltage and the electric lock. Pcb connectors fig. 2.11 shows the lay-out of connectors on the 2n ® helios ip force printe...

  • Page 25: Lan Connection

    Electric installation 2.3 25 description of connectors x1 loudspeaker x4 camera module x5 button 1 x6 configuration jumpers x8 extending module (rfid card reader or additional switch) x10 buttons 1 through 4 x11 lan x12 servicing connector x13 keypad module x15 left-hand microphone x16 right-hand mi...

  • Page 26: Electric Lock Connection

    Electric installation 2.3 26 electric lock connection 2n ® helios ip force is equipped with an electrically isolated relay switch with no and nc contacts (terminal block x17) and 12v/700ma switched output (terminal block x18), to which a standard electric lock or another compatible electrical applia...

  • Page 27: Mounting Completion

    Electric installation 2.3 27 mounting completion 1. Having connected all the wires, make sure that the bushings, if used, are tightened properly and the rj-45 connector is inserted in the pcb connector. 2. Replace the front cover carefully. Make sure that the connector is inserted correctly and the ...

  • Page 28: 2.4  Button Tags

    Button tags – insertion and replacement 2.4 28 2.4 button tags – insertion and replacement tag printing 1. Every 2n® helios ip force delivery includes a sheet of translucent foil, which can be laser-printed. Cut the printed foil and insert the tags in the name plates. 2. Every name plate includes a ...

  • Page 29: Function and

    29 3 3. Function and use in this section we describe the basic and extending functions of the 2n ® helios ip force product. Here is what you can find in this section: configuration control maintenance.

  • Page 31: 3.1  2N

    2n® helios ip force configuration 3.1 31 3.1 2n ® helios ip force configuration use a pc equipped with any web browser to configure 2n ® helios ip force: launch your web browser (internet explorer, firefox, etc.). Enter the ip address of your intercom ( http://192.168.1.100/ , e.G.). Log in using th...

  • Page 32

    2n® helios ip force configuration 3.1 32 wait for the first acoustic signal press buttons 2, 1, 1, 2, 2, 3 sequentially. The acoustic signal indicates mode switching. Wait until the device is restarted automatically. Note: the 2, 1, 1, 2, 2, 3 sequence must be entered within 30 seconds after the fir...

  • Page 33: 3.2  2N

    2n® helios ip force control 3.2 33 3.2 2n ® helios ip force control this subsection describes how to control 2n ® helios ip force when viewed by an external user. Speed dial buttons press the speed dial buttons on the basic unit to make quick dialling for the first 1, 2 or 4 positions (depending on ...

  • Page 34

    2n® helios ip force control 3.2 34 door opening (switch activation) by code 2n ® helios ip force is equipped with a door lock opening switch. Enter the valid code using your numerical keypad to activate the switch. Procedure: enter the numerical switch activating code using the numerical keypad and ...

  • Page 35: 3.3  Maintenance

    Maintenance 3.3 35 3.3 maintenance cleaning if used frequently, 2n ® helios ip force gets dirty. To clean it, use a piece of soft cloth moistened with clean water. We recommend you to obey the following principles while cleaning: never use aggressive detergents (such as abrasives or strong disinfect...

  • Page 37: Technical

    37 4 4. Technical parameters in this section we describe the technical parameters of the 2n ® helios ip force product..

  • Page 39: 4.1  Technical Parameters

    39 4.1 technical parameters signalling protocol sip (udp) buttons button design transparent, white backlit buttons with easily replaceable name tags count of buttons 1, 2 or 4 numerical keypad optional audio microphone 2 integrated microphones amplifier 10w (class d) loudspeaker 1w (optionally 10w) ...

  • Page 40

    40 supported cards em-40xx (125khz) hid proximity (125khz, 26bit) mechanical properties cover robust aluminium cast product, stainless steel front panel colour tbd working temperature -20°c to 55°c working relative humidity 10% - 95% (non-condensing) storing temperature -40°c to 70°c dimensions 217x...

  • Page 41: Supplementary

    41 5 5. Supplementary information this section provides supplementary information on the 2n ® helios ip force product. Here is what you can find in this section: applicable directives, laws and regulations.

  • Page 42

    Directives, laws and regulations 5.1 42 5.1 directives, laws and regulations 2n ® helios ip force conforms to the following directives and regulations: directive 1999/5/ec of the european parliament and of the council, of 9 march 1999 – on radio equipment and telecommunications terminal equipment an...

  • Page 43: 5.2  Troubleshooting

    Troubleshooting 5.2 43 5.2 troubleshooting for tips concerning solutions of other potential problems see faq.2n.Cz ..

  • Page 44

    General instructions and cautions 5.3 44 5.3 general instructions and cautions please read this user manual carefully before using the product. Follow all instructions and recommendations included herein. Any use of the product that is in contradiction with the instructions provided herein may resul...

  • Page 45

    General instructions and cautions 5.3 45 electric waste and used battery pack handling do not place used electric devices and battery packs into municipal waste containers. An undue disposal thereof might impair the environment! Deliver your expired electric appliances and battery packs removed from...

  • Page 46

    2n telekomunikace a.S. Modřanská 621, 143 01 prague 4, czech republic tel.: +420 261 301 500, fax: +420 261 301 599 e-mail: sales@2n.Cz web: www.2n.Cz dr1755 v1.0