2N Helios IP Vario Installation Manual

Other manuals for Helios IP Vario: Installation Manual, Installation Manual
Manual is about: Door Entry IP Intercom

Summary of Helios IP Vario

  • Page 1

    Www.2n.Cz version 2n ® helios ip vario door entry ip intercom installation manual 2.1.

  • Page 2: Content

    The 2n telekomunikace a.S. Is a czech manufacturer and supplier of telecommunications equipment. The product family developed by 2n telekomunikace a.S. Includes gsm gateways, private branch exchanges (pbx), and door and lift communicators. 2n telekomunikace a.S. Has been ranked among the czech top c...

  • Page 3: Content

    Content 1. Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 components and associated products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.2 terms and symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 4: 1. Product Overview

    4 2n telekomunikace a.S., www.2n.Cz ® 1. Product overview here is what you can find in this section: 1.1 components and associated products 1.2 terms and symbols basic features 2n ® helios ip vario is a highly reliable ip door access intercom provided with a lot of useful above-standard functions. S...

  • Page 5: Advantages of Use

    5 2n telekomunikace a.S., www.2n.Cz ® to manage extensive systems easily and quickly. Manager 2n ® helios ip vario advantages of use bidirectional communication – acoustic echo cancelling integrated colour camera optional dial buttons including name tags with backlight optional numerical keypad with...

  • Page 6: Basic Units

    6 2n telekomunikace a.S., www.2n.Cz ® 1.1 components and associated products basic units part no. 9137111(c)u basic unit 1 button part no. 9137131(c)u basic unit 3 buttons part no. 9137161(c)u basic unit 3× 2 buttons part no. 9137111(c)ku basic unit 1 button + keypad part no. 9137131(c)ku basic unit...

  • Page 7: Extending Modules

    7 2n telekomunikace a.S., www.2n.Cz ® extending modules 9135181e part no. Extending module8 buttons part no. 9135182e extending module 8× 2 buttons 9135310e part no. Info panel backlit panel without buttons; used for insertion of a telephone directory, company logo, house number, etc. Extenders 9135...

  • Page 8

    8 2n telekomunikace a.S., www.2n.Cz ® caution for flush or outdoor mounting you need to use the accessories; see the mounting accessories subsection..

  • Page 9: Mounting Accessories

    9 2n telekomunikace a.S., www.2n.Cz ® mounting accessories 9135331e part no. Surface 1-module roof (103 × 218 dimensions: × 60) mm (w × h × d) 9135351e part no. Wall mounting boxwith 1-module frame (125 × 235 dimensions: × 46) mm (w × h × d) (110 × 220 × wall hole: 50) ±5 mm 9135361e part no. Wall m...

  • Page 10: Voip Telephones

    10 2n telekomunikace a.S., www.2n.Cz ® 9135332e part no. Surface 2-module roof (203 × 218 dimensions: × 60) mm (w × h × d) 9135352e part no. Wall mounting boxwith 2-module frame (225 × 235 dimensions: × 46) mm (w × h × d) (210 × 220 × wall hole: 50) ±5 mm 9135362e part no. Wall mounting boxwith 2-mo...

  • Page 11: Electric Locks

    11 2n telekomunikace a.S., www.2n.Cz ® electric locks 932070e part no. Befo 1211 12 v / 600 ma 932080e part no. Befo 1221with momentum pin 932090e part no. Befo 1211mbwith mechanical blocking power supply part no. 91378100e part no. 91378100us poe injector 91341481e part no. Adapter 12 v / 2 a a sta...

  • Page 12: Additional Modules

    12 2n telekomunikace a.S., www.2n.Cz ® additional modules 9137310e part no. Additional switch additional appliance control, normally open/closed contact option, time-unlimited connection, up to 48 v / 2 a. 9137430e part no. Internal rfid card reader for 2n ® mo helios ip vario unting 9137420e part n...

  • Page 13: 1.2 Terms and Symbols

    13 2n telekomunikace a.S., www.2n.Cz ® 1.2 terms and symbols the following symbols and pictograms are used in the manual: safety abide by this information to prevent persons from injury. Always warning abide by this information to prevent damage to the device. Always caution important information fo...

  • Page 14

    14 2n telekomunikace a.S., www.2n.Cz ® 2. Description and installation here is what you can find in this section: 2.1 before you start 2.2 mechanical installation 2.3 electric installation 2.4 completion 2.5 extending module connection.

  • Page 15: 2.1 Before You Start

    15 2n telekomunikace a.S., www.2n.Cz ® 2.1 before you start product completeness check before you start please check whether the contents of the package of your new 2n ® complies with the following list. Helios ip vario 1× 2n ® helios ip vario 1× spare seal 1× drilling template 1× hexagonal wrench 1...

  • Page 16: 2.2 Mechanical Installation

    16 2n telekomunikace a.S., www.2n.Cz ® 2.2 mechanical installation overview of installation types an overview of the installation types and the list of the required components are provided in the table below..

  • Page 17

    17 2n telekomunikace a.S., www.2n.Cz ® installation type symbol what you need for installation indoor, on surface 2n ® helios ip vario only indoor, flush mounting 2n ® helios ip vario box with 1-module frame or 9135351e box with 2-module frame 9135352e outdoor, on surface 2n ® helios ip vario surfac...

  • Page 18: Surface Mounting

    18 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. Surface mounting drill holes according to the template included in the 2n ® helios ip vario supply. Insert the included dowels in the wall holes. Use the hexagonal wrench included in the supply and remove the 2n ® helios ip metal cover. Remove the scre...

  • Page 19

    19 2n telekomunikace a.S., www.2n.Cz ® 3. 4. 5. 6. 7. 8. In multiple-module assemblies connect the boxes, placing the basic module to the left and the extending modules to the right. The interconnecting cable shall be connected later! Install blank modules on the unused side holes as shown in figure...

  • Page 20

    20 2n telekomunikace a.S., www.2n.Cz ® 8. 9. 10. 11. 12. 13. 14. 15. Connect the cables as described in subsection 2.4, mounting – electrical installation. Make sure that the cables are not squeezed while installing the plastic cover. For the correct cable installation. Remove the protective foil fr...

  • Page 21: Flush Mounting

    21 2n telekomunikace a.S., www.2n.Cz ® 15. 16. 17. 18. 19. 20. Insert the printed foil labels. Put the inserts back in the name plates. Replace the name plates, clicking them into position. The name plates hold the matt foil inserted underneath. Check whether a silicon seal is inserted in the top gr...

  • Page 22

    22 2n telekomunikace a.S., www.2n.Cz ® caution the warranty shall not apply to product failures and defects caused by improper installation (contrary to these instructions). The manufacturer is neither liable for damages caused by theft within an area that is accessible after the attached electric l...

  • Page 23: 2.3 Electric Installation

    23 2n telekomunikace a.S., www.2n.Cz ® 2.3 electric installation 2n ® helios ip vario is designed for connection in the ethernet computer network (10/100base-t) using a utp cable. Use a cat 5e utp cable at least for connection. 2n ® helios ip vario is fed through the poe (power over ethernet) techno...

  • Page 24

    24 2n telekomunikace a.S., www.2n.Cz ® description of connectors, pcb versions 535v1, 535v2 figure:.

  • Page 25

    25 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. Description of connectors, pcb versions 535v5 figure: terminal block x2 connection terminal block x2 includes 10 terminals whose functions are distinguished by colour. Terminals 5–10 are used for connecting to the 2n ® helios ip vario ethernet. Term...

  • Page 26

    26 2n telekomunikace a.S., www.2n.Cz ® ethernet connection for the connections and meanings of the wires see the table below. Join utp cable wires 4 (blue) and 5 (white-blue) and attach them under terminal 6 on 2n ® helios ip in the same way, join wires 7 and 8 and place them under terminal 5 of var...

  • Page 27

    27 2n telekomunikace a.S., www.2n.Cz ® 1. 2. Whether the electric lock will be powered from an external or internal power supply. External power supply connection if the ethernet network is not equipped with the poe technology, you have two alternative options how to supply power to . 2n ® helios ip...

  • Page 28: Display Connector

    28 2n telekomunikace a.S., www.2n.Cz ® connection of configuration connector jumpers figure: display connector the display connector includes the name plate backlighting on/off switching pins and resetting pins. The remaining pins are intended for display 2n ® helios ip vario connection..

  • Page 29

    29 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 5. 6. Resetting procedure switch off. 2n ® helios ip vario connect the jumper into the resetting (default setting) position (put the display switch into the f_res position in the display-equipped models with 535v1 and 535v2 board versions). Switch o...

  • Page 30: Card Reader Connection

    30 2n telekomunikace a.S., www.2n.Cz ® resetting procedure – display model figure: to reset the default values of a display-equipped , put the switch 2n ® helios ip vario in the display right-hand bottom corner in position f_res. This applies to modules with board versions 535v1 and 535v2 only. For ...

  • Page 31

    31 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 5. 6. 7. 8. Card reader mounting power off . 2n ® helios ip vario use a hexagonal wrench to unscrew and remove the metal cover. Use a cross-head screwdriver to unscrew and remove the plastic cover. Connect the reader module into the basic unit botto...

  • Page 32: 2.4 Completion

    32 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 2.4 completion remember to seal the cable passage hole properly to 2n ® helios ip vario avoid moisture in-leak and damage to electronics due to condensation. Make sure that the wires inside are not squeezed and 2n ® helios ip vario insert the plastic t...

  • Page 33

    33 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 34

    34 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 35: Extending Button Modules

    35 2n telekomunikace a.S., www.2n.Cz ® 2.5 extending module connection 2n ® helios ip vario allows to connect following extending modules: extending button modules additional switch internal rfid card reader 125 khz security relay wiegand isolator extending button modules 2n ® helios ip vario featur...

  • Page 36

    36 2n telekomunikace a.S., www.2n.Cz ® maximum count of extenders 9135181e (1× 8 buttons) 6 5 4 3 2 1 0 9135182e (2× 8 buttons) 0 0 1 1 2 2 3 table 2.6 optional extension the table above shows how to combine modules with single (whole) and double buttons. Module cable interconnection the cable is in...

  • Page 37

    37 2n telekomunikace a.S., www.2n.Cz ® button numbering button numbering – one-button with a whole-button set button numbering – whole-button sets.

  • Page 38: Additional Switch

    38 2n telekomunikace a.S., www.2n.Cz ® button numbering – double-button set button numbering – info panel sets installing the info panel name plate, part no. 9135311e, into any of the extending modules will not change the numbering system (the buttons on the info panel sides will remain functional)....

  • Page 39

    39 2n telekomunikace a.S., www.2n.Cz ® function: the adds one additional switch to the 2n ® helios ip vario additional switch 2n ® basic unit. Helios ip vario specifications: passive switch: no and nc contacts, up to 30 v / 1 a ac/dc module mounting: switch off the intercom before module installatio...

  • Page 40

    40 2n telekomunikace a.S., www.2n.Cz ® connection: switch connection normally opened no - c normally closed nc - c internal rfid card reader 125 khz the internal rfid card reader (part no. 9137430 e) is used for reading rfid card ids in the 125 khz band. This module is intended for mounting into the...

  • Page 41

    41 2n telekomunikace a.S., www.2n.Cz ® 2 relay outputs 2 digital inputs wiegand interface signalling outputs (led / buzzer) specifications: card reader compatible with em4100 / em4102 / hid prox rfid cards ® working frequency: 125 khz minimum reading distance: 10 mm above cover 2n ® helios ip vario ...

  • Page 42: Security Relay

    42 2n telekomunikace a.S., www.2n.Cz ® module mounting: power off . 2n helios ip vario ® use a hexagonal wrench to unscrew and remove the metal cover. Use a cross-head screwdriver to unscrew and remove the plastic cover. Connect the reader module into the basic unit bottom 2n helios ip vario ® conne...

  • Page 43

    43 2n telekomunikace a.S., www.2n.Cz ® function: the is a device installed between an intercom (outside 2n helios ip security relay ® the secured area) and the electric lock (inside the secured area). The 2n helios ip ® includes a relay that can only be activated if the valid opening code is securit...

  • Page 44: Wiegand Isolator

    44 2n telekomunikace a.S., www.2n.Cz ® configuration: connect the to the properly set intercom switch 2n helios ip security relay ® output; refer to the . Make sure that one 2n helios ip configuration manual ® led at least on the is on or blinking. 2n helios ip security relay ® press and hold the re...

  • Page 45

    45 2n telekomunikace a.S., www.2n.Cz ® function: the separates galvanically a two-wire wiegand bus 2n helios ip wiegand isolator ® in one direction and a status led signal in the other direction. The module is power supplied from the wiegand bus receiver side. Specifications: 2-wire wiegand in 2-wir...

  • Page 46

    46 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 47: 3. Function and Use

    47 2n telekomunikace a.S., www.2n.Cz ® 3. Function and use this section describes the basic and extending functions of the the 2n ® helios ip product. Vario here is what you can find in this section: 3.1 configuration 3.2 intercom control as viewed by external user 3.3 display-equipped intercom as v...

  • Page 48: 3.1 Configuration

    48 2n telekomunikace a.S., www.2n.Cz ® 3.1 configuration use a pc equipped with any web browser to configure : 2n ® helios ip vario launch your web browser (internet explorer, firefox, etc.). Enter the ip address of your intercom (http://192.168.1.100/, e.G.). Log in using the user name and password...

  • Page 49: Static Ip Address Setting

    49 2n telekomunikace a.S., www.2n.Cz ® 6-buttons models: press the fifth quick dial button on the basic unit five times. 2n ® helios ip vario will read its ip address. If the address is 0.0.0.0, it means that the intercom has not obtained the ip address from the dhcp server. Static ip address settin...

  • Page 50

    50 2n telekomunikace a.S., www.2n.Cz ® figure 3.1 switching to static ip address 4, 4, 4, 5, 5, 6 for 6-buttons modely the acoustic signal indicates mode switching. Wait until the device is restarted automatically. The device will have the following network parameters after restart: ip address – 192...

  • Page 51: Dynamic Ip Address Setting

    51 2n telekomunikace a.S., www.2n.Cz ® dynamic ip address setting follow the instructions below to enable automatic getting of network parameters from the dhcp server: connect to the power supply (or, disconnect and reconnect 2n ® helios ip vario it if already connected). Wait for the first acoustic...

  • Page 52

    52 2n telekomunikace a.S., www.2n.Cz ® mode switching with 1-button models in case your device is equipped with 1 button, you can switch 2n ® helios ip vario the modes using one button only. Connect to the power supply (or, disconnect and reconnect 2n ® helios ip vario it if already connected). Wait...

  • Page 53: Quick Dialling Buttons

    53 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 3.2 intercom control as viewed by external user quick dialling buttons by pushing a quick dialling button on the basic unit you can call to positions 1, 3...6 of the telephone directory (depending on the model type). With extending modules you can u...

  • Page 54

    54 2n telekomunikace a.S., www.2n.Cz ® 4. . Subsection of configuration manual incoming call answer and reject if the automatic incoming call answer is disabled (refer to the intercom configuration / ), a call coming to services / phone / calls subsection of configuration manual 2n ® is signalled wi...

  • Page 55

    55 2n telekomunikace a.S., www.2n.Cz ® code type. An invalid code is announced by acoustic signalling ..

  • Page 56: User

    56 2n telekomunikace a.S., www.2n.Cz ® 3.3 display-equipped intercom as viewed by external user until the display program is uploaded to , the display shows the 2n ® helios ip vario following text: ; refer to the figure below. In 2n helios ip display is not configured this state, behaves and is cont...

  • Page 57: Calling to Number

    57 2n telekomunikace a.S., www.2n.Cz ® push the quick dialling button 6 to move to the telephone directory mode and the b utton to move to the mode (only if the telephone function is calling to number enabled, see ). Miscellaneous calling to number if the is selected (see ), telephone function enabl...

  • Page 58: Status Information

    58 2n telekomunikace a.S., www.2n.Cz ® entering the text to be searched selecting one of the contacts found the text string is retrieved on the current level and all sublevels of the telephone directory. The count of contacts found is displayed on the top line. The first 3 (or 4) found contacts are ...

  • Page 59: Call Answering

    59 2n telekomunikace a.S., www.2n.Cz ® 3.4 intercom control as viewed by internal user call answering incoming calls from can be received like any other call. You can 2n ® helios ip vario open the lock and activate or deactivate a user or profile during the call using your telephone numeric keypad. ...

  • Page 60

    60 2n telekomunikace a.S., www.2n.Cz ® profile activation and deactivation you can activate or deactivate a profile and define call routing to the telephone numbers assigned to the profile using the numeric keypad. For more details refer to the intercom configuration / directory / time profiles subs...

  • Page 61: 3.5 Maintenance

    61 2n telekomunikace a.S., www.2n.Cz ® 3.5 maintenance cleaning if used frequently, gets dirty. To clean it, use a piece of soft 2n ® helios ip vario cloth moistened with clean water. We recommend you to obey the following principles while cleaning: never use aggressive detergents (such as abrasives...

  • Page 62: 4. Technical Parameters

    62 2n telekomunikace a.S., www.2n.Cz ® 4. Technical parameters signalling protocol sip (udp, tcp, tls) buttons button design: stainless-steel push buttons count of buttons: 1, 3 or 6 button extension: up to 54 buttons numerical keypad: optional audio volume control: adjustable full duplex: yes (aec)...

  • Page 63: Video Stream

    63 2n telekomunikace a.S., www.2n.Cz ® video stream protocols: Ş rtp/rtsp/http codecs: h.263, h.263+, h.264, mpeg-4, m-jpeg ip camera function: yes interface power supply: 12 v ±15 % / 2 a dc or poe poe: poe 802.3af (class 0 - 12.95 w) lan: 10/100base-tx s auto-mdix recommended cabling: cat-5e or hi...

  • Page 64: 5. Supplementary Information

    64 2n telekomunikace a.S., www.2n.Cz ® 5. Supplementary information here is what you can find in this section: 5.1 troubleshooting 5.2 directives, laws and regulations 5.3 general instructions and cautions.

  • Page 65: 5.1 Troubleshooting

    65 2n telekomunikace a.S., www.2n.Cz ® 5.1 troubleshooting for the most frequently asked questions refer to . Faq.2n.Cz.

  • Page 66: Europe

    66 2n telekomunikace a.S., www.2n.Cz ® 5.2 directives, laws and regulations europe 2n ® helios ip vario conforms to the following directives and regulations: directive 1999/5/ec of the european parliament and of the council, of 9 march 1999 – on radio equipment and telecommunications terminal equipm...

  • Page 67: Fcc

    67 2n telekomunikace a.S., www.2n.Cz ® fcc note: this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in a residential installatio...

  • Page 68

    68 2n telekomunikace a.S., www.2n.Cz ® 5.3 general instructions and cautions please read this user manual carefully before using the product. Follow all instructions and recommendations included herein. Any use of the product that is in contradiction with the instructions provided herein may result ...

  • Page 69

    69 2n telekomunikace a.S., www.2n.Cz ® electric waste and used battery pack handling do not place used electric devices and battery packs into municipal waste containers. An undue disposal thereof might impair the environment! Deliver your expired electric appliances and battery packs removed from t...

  • Page 70

    70 2n telekomunikace a.S., www.2n.Cz ® 2n telekomunikace a.S. Modřanská 621, 143 01 prague 4, czech republic phone: +420 261 301 500, fax: +420 261 301 599 e-mail: sales@2n.Cz web: www.2n.Cz en1777_v2.0.1.