70-km Gigabit Ethernet GBIC Transceiver Installation Guide
The event log may show one of the following informational messages:
■
Unqualified GBIC: I2C read error
Meaning
The transceiver, which connects to the module host board through a
20-pin connector is not seated properly, and a clean connection
cannot be established.
Corrective action
To correct this problem, completely remove the transceiver and then
reinsert it. If the problem persists, contact 3Com Technical Support.
For contact information in the United States and Canada, call
1-800-NET-3COM. For the number to call in other locations, visit the
3Com Web site:
http://www.3com.com/util/enterprise.html
■
Unqualified GBIC: Checksum match error
Meaning
The system uses checksum error detection to verify the integrity of the
GBIC data. If the system detects a problem with the data, it displays
an error message that indicates a checksum failure.
Corrective action
Although this condition does not necessarily indicate that the GBIC
transceiver will not function in the system, replace the transceiver to
ensure proper operation.
■
Unqualified GBIC: MODDEF Value – xx
■
Unqualified GBIC: Transceiver byte(s) error
Meaning
For both of these messages, the value (
xx
) of this GBIC type is not a
Module Definition 4 GBIC (Serial Identification) as defined by the
Gigabit Interface Converter specification.
Corrective action
Replace this transceiver with a GBIC that is qualified by 3Com.