3D Systems ProJet 1200 User manual - page 29
24
3D Systems, Inc.
7 . Test the connection by selecting
Test Post Cure
from the
Help
Tab .
.
NOTE: The curing chamber carousel should rotate if the printer
is connected . The curing door must be shut to perform this
operation .
Activating Printer
Printer must first be activated before you can add it. You will know if the printer
needs to be activated if you go to add it and a dialog box pops up. (1)
1 . Fill in all the fields and select
Next
.
NOTE: An internet connection is required to activate the printer .
2 . The printer will now be activated through the 3DSSystems activation server .
3 . Enter a name for the printer . Click
Next
.
4 . Choose the printer and click
Set As Current
(this will set the printer as
current) .
5 . The printer is now ready to use .
Test Material Cartridge
Before removing label from material cartridge, test to ensure cartridge is inserted
properly .
1 . Select Check Cartridge from the Help tab .
2 . If cartridge is not inserted properly an error will occur .
3 . If cartridge is okay, a window will pop up letting user know how much material
is left in cartridge . When new it will say 100% .
4 . Once cartridge is determined to be okay, you can carefully pull back the label .
NOTE: Do not move the machine with the cartridge inside once
it is opened .
1