3D Systems ProX DMP 100 User Manual - page 79
75
3D SYSTEMS, INC
.
PN:80-D48 REV A
EVERY 6 MONTHS MAINTENANCE
Gas filter replacement
The gas filter must be replaced every 6 months. The gas filter is located under the front doors.
Part required :
•
Filter element : 1001884R00 .
1 . Make sure the gas and purge are not activated .
2 . Open the access door located below the front doors of the machine (1) .
3 .
Remove the filter guard from the filter cap by unscrewing it (2).
4 .
Remove the filter element. Dispose of it in accordance with all local/regional/national, state and federal regulations.
WARNING : FLAMMABLE POWDERS .
PLACE THE USED FILTER ELEMENT IN A CLOSED METALLIC CONTAINER IN A ROOM WITH FIRE DETECTION .
5 .
Clean the filter guard with the use of a damp cotton cloth.
6 .
Install the new filter element.
7 .
Install the filter guard.
8 . Close the access door located below the main cabinet .
1
Filter cap
Filter guard
2