3M Aqua-Pure AP801 Housing Installation And Operating Instruction Manual - Caution
IMPORTANT INSTALLATION INSTRUCTIONS
1. Shut off main water supply.
Relieve pressure from water lines.
2. Remove housing from filter head and set aside.
3. WrapPTFEtapearoundthe1”malecompressionadaptors(totheright,see
Figure 1) and install into filter head. Do not use pipe solvent (dope) as
some types may cause damage to plastic fittings. Do not overtighten as it
may cause damage to filter head. Damage to unit may result in property
damage due to water leakage.
4. Calculate proper spacing of components. Measure distance and mark pipe accordingly.
5. Cut pipe to length with pipe cutter.
6.
Install filter head and ball shut-off valve onto pipe. Make sure the the filter is connected with the correct flow direc-
tion. Tighten compression nuts.
7. Remove o-ring from housing.
Lubricate with water and seat securely on housing.
8.
Place cartridge into housing. Install housing onto head.
9. Slowly turn on main water supply. Press red air release button (on filter head) to expel air.
10.
Check for leaks.
11.
Flush at least 10.5 gallons through system.
CAUTION
WARNING
To reduce the risk associated with hazardous
voltage:
•Ifthehomeelectricalsystemrequiresuseof
thecoldwatersystemasanelectricalsafety
ground,ajumper
mustbeusedtoensurea
sufficientgroundconnectionacrossthefilter
installationpiping—referinstallationtoquali-
fiedpersonnel.(seeFigure2)
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
• Protect from freezing, remove filter cartridge when temperatures are expected to drop below 40°F (4.4°C).
• SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER after water is shut off.
Ground Wire
Ground Clamp
Ground Clamp
Figure 2
Figure 1
4