AD-4402-20
Page 17
4.3.5.
4.3.5.
4.3.5.
4.3.5.
Reading Commands
Reading Commands
Reading Commands
Reading Commands
1 Set a material code (No. 33) or recipe code (No. 57) in the storing command (RWw000E).
2 Turn on the Read/Write selection (RY0003).
3 Set the kind of data to the command code (RWw000E)
4 The result is output to the reply register (RWr000C to 000D).
4.3.6.
4.3.6.
4.3.6.
4.3.6.
Storing Commands
Storing Commands
Storing Commands
Storing Commands
1 Set a material code (No. 33) or recipe code (No. 57) in the storing command (RWw000E).
2 Turn off the Read/Write selection (RY0003).
3
Set the kind of data to the command code (RWw000E)
4 Set data to the command register (RWw000C, RWw000D).
Request flag to store setpoint (RY0000)
Setpoints (RWw0000 to RWw000B)
Reply flag to store setpoints (RX0000)
Step 3
Step 4
Command request flag (RY0002)
Command data reply (RWr000C, RWr000D)
Read/Write reply (RX0003)
Read/Write selection (RY0003)
Command code (RWw000E)
Command code reply (RWr000E)
Command reply flag (RX0002)
Step 2
Step 2
Command request flag (RY0002)
Command data (RWw000C, RWw000D)
Read/Write reply (RX0003)
Read/Write selection (RY0003)
Command code (RWw000E)
Command code reply (RWr000E)
Command reply flag (RX0002)