A&D LCC11T010-K Instruction Manual

Summary of LCC11T010-K

  • Page 1

    Msawt001 ページ 1 lcc11 シリーズ 圧縮型ロードセル lcc11 series compression load cells 取 扱 説 明 書 instruction manual 1wmpd4000448b.

  • Page 2

    - 1 - english 1. Precautions this is a caution mark. Note important information that helps users to operate the product. 2004 all rights reserved. This manual is subject to change without notice at any time to improve the product. No part of this manual may be photocopied, reproduced, or translated ...

  • Page 3

    - 2 - 4. Specifications rated capacities.....................................100 kn, 200 kn, 300 kn rated output...........................................2mv/v±0.1% maximum safe overload .........................200%r.C. Combined error ......................................±0.016%r.O. Zero balance ...

  • Page 4

    - 3 - step 2 there are rotation stopper pins on the load cell. Insert each pin into the guide of the lower socket. Arrange the direction of the load cell cable along a wider movement of the bearing plate to prevent interference between these pins and the lower socket. Example: for a truck scale, arr...

  • Page 5

    - 4 - 6. Socket shapes when you make sockets, use the following drawing. The hardness of the socket is hrc32 to 38. 7. Caution design the structure to install the load cell strong enough to withstand the load. Make the foundation structure at the load cells, strong enough to support them. Confirm th...

  • Page 6

    - 5 - do not input any excessive excitation voltage above the tolerance, it will cause damage to the load cell. Avoid shock and overload to the load cell. Use lubricant between the load cell and sockets. When the welding is executed, ground the earth line and disconnect the load cell cable from the ...

  • Page 7

    - 6 - 12 φ72 φ94 19 9± 1 10 3 36 12 12 36 10 0 84 φ72 28 grounding terminal m4 4-wire shield cable pt-1/2 dust cover φ99 10 8 47 42 8- φ20 both plate 200±1 140 10 0 150 ±1 support load upper dust cover 84 φ34 pt-1/2 135 ±0 .5 83 14 .5 φ43 φ94 3 37 .5 4 30 12 84 47 42 83 17 grounding terminal m4 4-wi...

  • Page 8

    3-23-14 higashi-ikebukuro, toshima-ku, tokyo 170-0013 japan telephone: [81] (3) 5391-6132 fax: [81] (3) 5391-6148 a&d engineering, inc. 1756 automation parkway, san jose, california 95131 u.S.A. Telephone: [1] (408) 263-5333 fax: [1] (408)263-0119 a&d instruments limited unit 24/26 blacklands way, a...