A-Star 2018 ED Installation Programming Troubleshooting - page 11
11
PROGRAM THE TIMER:
"ELECTRONIC DEMAND TIMER
CONTROL SETTINGS REQUIRED UPON INSTALLATION.
NOTES:
o
When the transformer is plugged in, the model code F 18 shows in the face plate
display for a few seconds. The model code is then followed by a test number
(example: J1.1). After the test number, 12:00 PM and the words “PRESENT
TIME” begin to flash in the display.
o
If ---- is flashing, use the UP ▲ button to set the code to F18. If you pass by the
correct code number, use the DOWN ▼ button. Then press the SELECT button
to accept the correct model.
o
A “beep” sounds while pressing buttons for control programming. One beep
signals a change in the control display. Repeated beeps mean the control will not
accept a change from the button you have pressed, and you should select
another button.
o
To program the control, you will use the UP ▲, DOWN ▼ and SELECT buttons.
PROGRAM MEMORY:
If electrical power to the softener is interrupted, the time display is blank, but the timer
keeps correct time for about 6 hours. When power is restored, you have to reset the
present time only if the display is flashing. All other settings are maintained and never
require resetting unless a change is desired.
SET PRESENT TIME OF DAY
1. Press the SELECT button until a flashing 12:00 PM and the words “PRESENT
TIME” are shown in the display.
2. Press UP ▲or DOWN ▼ button to set. The UP ▲ button
advances the time; the DOWN ▼button moves the time
in reverse. If the present time is between noon and
midnight, be sure PM shows in the display. If the
present time is between midnight and noon, be sure
AM shows in the display.
NOTE: Each press of an UP ▲ or DOWN ▼ button
changes the time by one minute. Holding the button
changes the time at a rapid rate.
3. When the present time is correct, press SELECT to accept.
SET WATER HARDNESS NUMBER
1. Press the SELECT button a flashing 25 and the word
“HARDNESS” are shown in the display.
2. Press UP ▲ or DOWN ▼ button to set your water