Abbra Fully Supervised Wireless Alarm Control System Installer's Manual - page 19
ABBRA INSTALLATION GUIDE Version.04 4/12/17
19
4.6.4 GSM Line Failure Reporting
Here you determine whether GSM network failure will be
reported after 2 min., after 5 minutes, after 15 min., or after
30 minutes.
Available options:
don't report
,
2 min
,
5 min
,
15 min
, or
30 min
.
4.6.5 GSM Line Purpose
Define whether the GSM unit will serve as a backup for the
regular telephone line, as a primary communication
channel or as the only telephone channel or for sending
SMS only.
Available options are:
GSM is backup, GSM is primary
or
GSM only
or
SMS only
.
4.7 DEFINING OUTPUT PARAMETERS
4.7.1 Preliminary Guidance
This mode allows you:
a. Events/conditions selection under which the PGM
(programmable) output and fifteen “X-10” devices will
function.
b. Function type selection for every X-10 unit and for PGM
output.
c. General definitions selection for X-10 units
d. Selection of the internal siren or STROBE light (that will
be activated according to system programming).
e. Enrolling 2-way X-10 units.
The process is shown in Fig. 4.7. Each selected option is
displayed with a dark box at the right side. To review the
options, repeatedly press
the desired option is displayed, then press
button.
4.7.2 Define PGM
For the PGM output, you can select
disable, turn on
,
turn
off
or
pulse active
(turn on for predefined period, selected
by
PULSE TIME
), as follows:
n
BY ARM AWAY (
upon AWAY arming).
n
BY ARM HOME
(upon HOME arming).
n
BY DISARM
(upon disarming).
n
BY MEMORY
(activated upon registration of an alarm in
the memory, turned off upon memory clearing).
n
BY DELAY
(during exit / entry delays).
n
BY KEYFOB
(upon AUX button pressing in the keyfob
transmitter / MCM-140+, if “
PGM/X-10
” is selected in
“Define Panel” menu, location 17).
n
BY ZONES
(by disturbance in each of 3 selected zones,
irrespective of arming / disarming). If you select
toggle
,
the PGM output will be turned on upon event occurrence
in these zones and will be turned off upon next event
occurrence, alternately.
n
BY LINE FAIL:
PGM output is ON if telephone line is
disconnected.
4.7.3 Defining INT/STRB
Here you determine if the INT output will be used for an
internal siren
or for a
strobe
.
4.7.4 X-10 GENERAL DEF
(Not evaluated by UL)
For X-10 devices, you can select the following actions:
n
FLASH ON ALARM
(you can select
no flash
or
all light
flash
, to control X-10 lighting devices in alarm
conditions).
n
TRBL INDICATION
(you can select
don't indicate
or
indicate
for X-10 failure indication by the TROUBLE
LED).
n
FAIL REPORT
(You can select
report to central
station 1
,
report to central station 2, report to pager,
report to private telephone
and
send SMS
, for X-10
devices failure reporting).
n
3 PHASES & FREQ
(you can select
disable 3 phase
,
3
phase 50 Hz
, or
3 phase 60 Hz
to define the X-10
signal transmission type).
n
LOCKOUT TIME
(You can enter daytime limits between
which X-10 lighting devices controlled by sensors will be
off, even when the associated sensors are triggered).
In UL installations, this function shall not be used.
4.7.5 X-10 UNIT DEFINE
(Not evaluated by UL)
For the fifteen X-10 units you can perform the following
programming actions:
a. House code selection (a code letter from A to P that will
distinguish the site in which the system is installed from
other sites in the neighborhood).
b. Specific number definition for every X-10 unit (01 – 15).
c. Enrolling 1-way X-10 units
d. Enrolling 2-way X-10 units (that can perform status reporting).
Note:
If a 2-way X-10 unit is installed without enrolling,
interference to the 1-way X-10 units operation may
occur.
e. For each X-10 unit you can select
disable, turn on
,
turn
off
or
pulse active
(turn on for predefined period,
selected by
PULSE TIME
), upon the following
conditions:
n
BY ARM AWAY (
upon AWAY arming).
n
BY ARM HOME
(upon HOME arming).
n
BY DISARM
(upon disarming).
n
BY MEMORY
(activated upon registration of an alarm
in the memory, turned off upon memory clearing).
n
BY DELAY
(during exit / entry delays).
n
BY KEYFOB
(upon AUX button pressing in the
keyfob transmitter / MCM-140+, if “
PGM/X-10
” is
selected in “Define Panel” menu, location 17).
n
BY ZONES
(by disturbance in each of 3 selected
zones, irrespective of arming / disarming). If you
select
toggle
, the PGM output will be turned on upon
event occurrence in these zones and will be turned off
upon next event occurrence, alternately.