Abbra Fully Supervised Wireless Alarm Control System Installer's Manual - page 3
ABBRA INSTALLATION GUIDE Version.04 4/12/17
3
1. INTRODUCTION
The Abbra is a user and installer-friendly, 30-zone fully-
supervised wireless control system. The system is based
on the versatile Visonic Powermax+ platform, with added
functionality to take advantage of internet monitoring and
E-Notify through NextAlarm.com.
EASY TO INSTALL
•
Easy plug-in AC power supply.
•
Quick attach-detach TELCO sockets for telephone line
and X-10 controller. Terminal block for telephone line &
set.
•
Special wall-mounted bracket permits installation without
having to open the unit’s cabinet.
•
Optional plug-in RS-232 module for local computer.
EASY TO MAINTAIN
•
Status, alarm memory and trouble data are displayed
upon request.
•
Diagnostic test provides visual and audible indication of
the signal level of each detector.
•
Remote control and status verification from distant
telephones.
•
Event log stores and displays information on 100 past
events.
•
Upload / download from remote computer via telephone
line and modem.
QUICK PROGRAMMING
•
Multiple-choice selection of options for each parameter.
•
Clear visual prompts and audible signals.
•
Installer access to the user menu.
A NOTE ON DIAGRAMS
•
To ensure ease of reading and proper formatting,
OK
>
is used on diagrams in place of the longer
VIEW/SELECT
>, and
NEXT
> in place of
NEXT
ITEM
>. In addition, some pictures
2. SPECIFICATIONS
2.1 General Data
Zones Number:
28 wireless, 2 hardwired (zones 29 & 30).
Hardwired Zone Requirements:
2.2 k
Ω
E.O.L. resistance
(max. resistance of wires 220
Ω).
Zone Types:
Interior follower, interior, perimeter, perimeter
follower, delay 1, delay 2,
24h silent, 24h audible, fire, non-
alarm, emergency, gas and flood.
User Codes:
8 codes, 4 digits each
Control Facilities:
- Integral keypad
- PowerCode / Code-Secure™ hand-held transmitters
- Wireless commander, MCM-140+
- Remote telephone
- Local or remote computer
Display:
Single line, Backlit 16-character LCD with 4 LED
indicators.
Arming Modes:
AWAY, HOME, AWAY-INSTANT,
HOME-INSTANT, LATCHKEY, FORCED, BYPASS.
Alarm Types:
Silent alarm, siren alarm or sounder
(internal) alarm, in accordance with zone attributes.
Siren Signals:
Continuous (intrusion / 24 hours / panic);
triple pulse - pause - triple pulse... (fire).
Siren (bell) Timeout:
Programmable (4 min. by default)
Internal Sounder Output:
At least 85 dBA at 10 ft (3 m)
Supervision:
Programmable time frame for inactivity alert
Special Functions:
- Speech and sound control
- Powerline Carrier Device Control (up to fifteen X-10
brand units) by various factors, as programmed
- Chime zones
- Diagnostic test and event log
- Remote control by telephone
- Computer control and data download/upload
- Calling for help by using an emergency transmitter
- Tracing inactivity of elderly, physically handicapped and
infirm people
- Message center (recording and playback)
- Two-way voice communication
Data Retrieval:
Status, alarm memory, trouble, event log.
Real Time Clock:
The control panel keeps and displays
time and date.
Compliance with U.S. Standards:
Meets FCC Part 15 and Part 68 requirements.
UL1023 - Household Burglar Alarm System Unit - Grade A.
UL985 - Household fire warning System.
UL1635 – Digital Alarm Communicator System Units.
Compliance with European Standards:
EMC Emission:
EN 50081-1 1992, EN300220-3
RFI:
EN55022 1998
EMC Immunity:
EN 50082-1 1997, EN301489-3
EMC Immunity to Conducted RF:
EN6100-4-6 1996
Telephony:
TBR21 1998
Safety:
EN60950+ Am1(93), Am2(93), Am3(95), Am4(97)
According to the European standard EN50131-1, the
Abbra security grading is 2 – "low to medium risk" and
environmental classification is II – "indoor general".
The Abbra is compatible with the RTTE requirements -
Directive 1999/5/EC of the European Parliament and of the
Council of 9 March 1999.
2.2 RF Section
Operating Frequencies:
315 MHz (in USA & Canada) or
other UHF channels per local requirement in the country of
use.
Receiver Type:
Super-heterodyne, fixed frequency
Receiver Range:
600 ft (180 m) in open space
Antenna Type:
Spatial diversity
Coding:
PowerCode and/or CodeSecure™
2.3 Electrical Data
Power Supply:
Plug-in transformer.
120 VAC, 60 Hz / 9 VAC, 1A
Note:
It is possible to use 700 mA transformer if the used
siren current consumption is less than 300 mA.
UL installation
: Use transformer type OH-41111AT,
manufactured by Oriental Hero Electrical Factory.
Current Drain:
Approx. 65 mA standby, 800 mA at full
load and in alarm.