ABS 100 Installation And Operating Instructions Manual - page 13
13
ABS lifting station Piranhamat
ABS lifting station Piranhamat
6.3.4
R m v f h P h m 100/10
11
12-00
Figure 10. Emptying the Tank
Before dismantling the discharge and inflow lines, it is possible to empty the tank by driving the pump by means
of an electric drill.
In order to do this,
Pull the latches (9/2) on the tank cover (9/1) lightly to the outside and lift off the cover (9/1).
Remove the float protection (9/6).
Withdraw cap (9/7) from motorhousing.
Unscrew plugscrew (9/8) and clear a possible blockage of the cutting system by rotating the rotorshaft with a
screwdriver (10/1).
Finally fit a drill with screwdriver attachment (10/2).
NOTE
By driving the rotorshaft with an electric drill, the hydraulic system of the Piranhamat
100/120 will be operated and the tank emptied.
Switch on the drill and allow to run until the tank is empty.
Screw in plugscrew (9/8), fit cap (8/7), replace float protection (9/6) and replace tank cover (9/1).
Dismantle discharge and inflow lines.
-
-
-
-
-
-
-
-